Gebruiksaanwijzing /service van het product I 52.329363 30 GALLON van de fabrikant Kenmore
Ga naar pagina of 32
Owner's ManuaJ ® POWER MISERTM ELECTRIC WATER HEATER FOR POTABLE WATER HEATING ONLY. NOT SUITABLE FOR SPACE HEATING. 9 MODEL NO. 153.329264 38 Gallon Short 153.329265 38 Gallon Short 153.329362 30 Gallon i 52.329363 30 Gallon i 53.329462 40 Gallon i 53.
Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater. Many safety=related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard.
Read and understand instruction manual and safety messages before installing, operating or servicing this water heater. Failure tofollow instructions and safety messages could result in death or serious injury. Instruction manual must remain with water heater.
"q! SAFE INSTALLATION, USEAND SERVICE ........................................................................................................................................ 2 GENERAL SAFETY ......................................................
Thank You for purchasing a Sears water heater. Properly installed and maintained, it should give you years of trouble free service. It is strongly suggested that this new water heater be professionally installed, contact thelocal Sears Service Center or any Sears store.
Materials Needed To simplify the installation Sears has available the installation parts shown below. You may or may not need all of these materials, depending on your type of installation.
Removing the Old Water Heater 1. Turn "OFF" electrical supply to the water heater. FIGURE 1. 2. Turn "OFF" the water supply to the water heater at the water shut-off valve or water meter. FIGURE 2. 3. Attach a hose to the water heater drain valve and put the other end in a floor drain or outdoors.
Mineral Buildup or Sediment IVlayAccumalate . This causes the water heater to become much heavier than normal. ® If spilled, could cause staining. Mineral buildup or sediment may have accumulated in the old water heater. This causes the water heater to be much heavier than normal and this residue, if spilled out, could cause staining.
Fire Hazard / Electric Shock Hazard - Do not use this water heater with any voltage other than shown on the model rating plate. - Failure to use the correct voltage shown on the model rating plate could result in death, serious bodily injury, or property damage.
NOTE: To protect against untimely corrosion of hot and cold water fittings, it is strongly recommended that di=electric unions or couplings be installed on this water heater when connected to copper pipe. Fit T & P valve insulation over valve. Make sure that the insulation does not interfere with the lever of the T & P valve.
Position the valve downward and provide tubing so that any discharge will exit only within 6 inches (153 mm) above, or at any distance below the structural floor. Be certain that no contact is made with any live electrical part. The discharge opening must not be blocked or reduced in size under any circumstances.
Converting the Lower Element These instructions only cover the conversion of the convertible element, read this entire manual before attempting to install or operate the water heater. The water heater is factory set to operate at 3800 watts. The lower element can be converted to operate at 5500 watts.
5. 6. LiFT OUT TAB TO UNCLIP TERMINAL COVER FROM THERMOSTAT FIGURE 16. Remove the screws from terminal 2 of the element, and move the looped end of the wire aside. FIGURE 17. The buss bar is labeled 5500 W. Place the buss bar over terminals 2 and 3 with the 5500 W visible.
11. Replace the access panel. FIGURE 21. 12. Complete wiring to the water heater, or if completed, turn "ON" electric power to the water heater after filling the tank with water. FIGURE 22, improper installation and use may result in property damage.
5. Wiring Diagrams (see "Wiring Diagrams" section) have been supplied showing the two most common types of connections between the water heater and the power supply. You can easily see which type connection you have by removing the junction box cover on top of the water heater.
Wiring Diagrams [ STANDARD WIRING FOR 2 WIRE LEAD WATER HEATERS NON-SIMULTANEOUS OPERATION 240 VOLT DOUBLE ELEMENT A6 GROUND TE"M'NAL------F:-_I_-- * Before removing any access ,, Tl__T2?owersuPpLY panels or servicing the water ol ,.
Temperature Regulation Water temperature over 125°F (52°C) can cause severe burns instantly resulting in severe injury or death• Children, the elderly, and the physically or mentally disabled are at highest risk for scald injury. Feel water before bathing or showering• Temperature limiting valves are available.
NOTE: It is not necessary to adjust the upper thermostat. However, if it is adjusted above the factory set point of 120°F (49°C), it is recommended that it not be sethigher than the lower thermostat setting. The upper and lower thermostats are adjustable if a different water temperature is desired.
The water heater should be drained if being shut down during freezing temperatures. Also, periodic draining and cleaning of sediment from the tank may be necessary. l • Before removing any access panels or servicing the water heater, make sure the electrical supply to the water heater is turned "OFF".
[ o Before removing any access panels or servicing the water heater, make sure the electrical supply to the water heater is turned "OFF". • Failure to do this could result in death, serious bodily injury, or property damage. Remove the two screws securing the access panel, and remove panel.
8. g. Clean the area around the element opening. Remove any sediment from or around the element opening, inside the tank. If you are cleaning the element you have removed, do so by scraping or soaking in vinegar or a de-liming solution.
18. Replace access panel. 19. Turn "ON" electric power to water heater. FIGURE 41. Drain Valve Washer Replacement [ . Before removing any access panels or servicing the water heater, make sure the electrical supply to the water heater is turned "OFF".
Start Up Conditions THERMAL EXPANSION Property Damage Hazard • Avoid water heater damage. . Install thermal expansion tank or device if necessary. - Contact qualified installer or service agency.
D.An excess ofactive hydrogen inthe tank. This is caused by corrosion protective action ofthe anode. Smelly water may be eliminated or reduced in some water heater models by replacing the anode rod (s) with one ofless active material, and then chlorinating the water heater tank and allhot water lines.
2. 3. 4. 5. 6. 7. Make sure the electrical supply to your water heater is "ON". Check for loose or blown fuses in your water heater circuit. Circuit breakers weaken with age and may not handle their rated load and should be replaced. Make certain the disconnect switch, if used, is in the "ON" position.
Never use this water heater unless it is completely full of water. To prevent damage to the tank and heating element, the tank must be filled with water. The water must flow from the hot water faucet before turning "ON" power. A. *Condensation may be seen on pipes in humid weather or pipe connections may be leaking.
KENMORE POWER MISER TM 9 ELECTRIC WATER HEATERS I 153.329264 I 38 Gallon Short I I 153.329265 I 38 Gallon Short I NOTE:A UPPER ELEMENT: These water heaters are equipped with 3800 watt elements. LOWER ELEMENT: These water heaters are equipped with factory installed convertible elements, which can be operated at 3800 watts or 5500 watts.
KENMORE POWER MISER TM 9 ELECTRIC WATER HEATERS 153.329362 153.329363 153.329462 153.329463 153.329562 NOTE:A 30 Gallon 30 Gallon 40 Gallon 40 Gallon 55 Gallon UPPER ELEMENT: These water heaters are equipped with 3800 watt elements.
KENMORE POWER MBER TM 9 ELECTRIC WATER HEATERS I53.329563 I53.329662 I53.329663 153.329862 153.329863 NOTE:A 55 Gallon 66 Gallon 66 Gallon 80 Gallon 80 Gallon UPPER ELEMENT: These water heaters are equipped with 3800 watt elements.
30.
31.
9 - YEAR LIMITED WARRANTY ON WATER HEATER For nine years from the date of purchase, if this water heater is installed and operated in a single-family home in accordance with the owner's manual instructions and all local applicable plumbing codes, Sears will: 1.
Een belangrijk punt na aankoop van elk apparaat Kenmore I 52.329363 30 GALLON (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Kenmore I 52.329363 30 GALLON heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Kenmore I 52.329363 30 GALLON vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Kenmore I 52.329363 30 GALLON leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Kenmore I 52.329363 30 GALLON krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Kenmore I 52.329363 30 GALLON bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Kenmore I 52.329363 30 GALLON kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Kenmore I 52.329363 30 GALLON . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.