Gebruiksaanwijzing /service van het product ULTRAFILTER 650 625.38556 van de fabrikant Kenmore
Ga naar pagina of 28
OWNER'S MANUAL E L I T Reverse Osmosis System MODEL NO. 625.385560 UltraFilter 650 I Z O O R _D _m D m i D _W _D Caution: Read and follow all safety rules and operating instructions before first use of this product. Questions ? Visit www.KenmoreWater.
ONE YEAR FULL WARRANTY ON REVERSE OSMOSIS SYSTEM When installed, operated and maintained according to all instructions supplied with the product, if this Reverse Osmosis System fails due to a defect i.
Unpack and Check Shipment ............................................................................. 4 What Your Reverse Osmosis System Will do ............................................................... 5 Plan Your installation ...............
INSPECT SHIPMENT Your Reverse Osmosis Drinking Water System is shipped complete in one carton. Remove all items from your shipping carton. Check all items against the packing list below. Note any items lost or damaged in shipment. Note any damage to the shipping carton.
Your Reverse Osmosis (RO) Drinking Water System is a water treatment unit. It uses household water pressure to reverse a natural physical process called osmosis. Water, under pressure, is forced through a semi-permeable membrane where minerals and impurities are filtered out.
Typical Under Sink Installation All install parts included in package. Drain Adapter for Reverse Osmosis Waste Water Reverse Osmosis Assembly Figure 2 Soft, Cold Water Typical Remote Installation Outside Faucet (Hard Water) Outside Faucet (]E tard Water) TO Reverse Osmosis Air Gap Faucet Soft, Hot Water Additional Parts required.
OVERVIEW There are seven easy steps to installing your Drinking Water system. They are as follows: STEP 1 - install Cold Water Supply fitting STEP STEP STEP STEP STEP STEP 2 - install Drain Adapter 3 .
CHOOSE TYPE OF WATER FITTING TO INSTALL Locate the cold water line in the sink cabinet. It is recom- mended, but not required, that the cold water line be soft water. You can use the saddle valve provided with your unit to tap into the cold water line.
INTRODUCTION A suitable drain point is needed for the reject water from the Reverse Osmosis Filter. You have two options to choose from: * Install the Drain Adapter included with your unit See Figures 6, 7 & 8. This is used in under the sink installations.
Outside Faucet (Hard Water) Soft, Cold Water Soft, Hot Water Remote Location Installation _ Sump I-F Airgap H I-1/Z' Stand pipe Airgap 1!4" RED Tubing Outside Faucet (Hard Water) Line GREEN .
INSTALL REVERSE OSMOSIS FILTER ASSEMBLY The Reverse Osmosis Filter Assembly can sit upright or lay on it's side. When planning your installation, you need to allow adequate tubing lengths to be able to access the back of the Reverse Osmosis assembly in order to change the monitor battery.
SELECT LOCATION OF REVERSE OSMOSIS FAUCET MOUNTING HOLE You will need to select the location of the Reverse Osmosis Faucet. You have three options to choose from: faucet • Use the existing sink top .
NOTE: If you ran the red reverse osmosis drain tubing directly to a remote drain point, disregard steps 5 and 6 and refer to instructions on page 10. 6. Mount the faucet body on to the faucet base, 1/4 turn. FAUCET ELECTRONICS The RO system will monitor the total product flow of the unit and also length of time the filters have been installed.
HOW TO CUT AND CONNECT THE TUBES Your Reverse Osmosis Water System includes push-in fittings for quick tubing connection. Review the follow- ing instructions before connecting the tubes in the next step. Push In Fitting_ TubeN,4K Cut tubes to length 1.
water supply fitting 3/8" black tubing _ II II II 1/4" red tubing / blue tubing NOTE: Tubing lengths should allow access to the back of the assembly for servicing. NOTE: Codes in the state of Massachusetts require installation by a licensed plumber and do not permit the use of saddle valves.
SANITIZE THE SYSTEM Sanitizing is recommended immediately after installation of the Reverse Osmosis system. It's also recommended after servicing inner parts. It is important that the person installing or servicing the system have clean hands while handling inner parts of the system.
PRESSURE TEST THE SYSTEM NOTE: Complete the sanitizing procedures on the pre- ceding page before pressure testing. To pressure test the system, complete the following steps. 1. Turn the handle of the saddle valve counterclockwise to open the valve. See Fig.
HOW YOUR REVERSE OSMOSIS SYSTEM WORKS Introduction: Your Reverse Osmosis (RO) Drinking Water System uses your household water pressure to force water through three filters. Minerals and impurities are filtered out. Delicious tasting drinking water goes to the storage tank-ready for your use.
PRODUCT WATER FAUCET air @ WASTE WATER WATER iN RED "_ dgravity rain AUTOMATIC drain flow SHUTOFF control GREEN PREFILTER t_ _ t RO MEMBRANE [!1 PRODUCT WATER check valve O BLUE Jl IL POSTFILTER Reverse Osmosis Water Flow Schematic D YELLOW i D Figure 24 Water Flow Description 1.
PREFILTER/POSTFILTER MAINTENANCE NOTE: It is recommended to replace the battery, prefilter and postfilter cartridges at least every 6 months of prod- uct water use. Replace more often if they begin to plug with sediments. The prefilter and postfilter are replaceable sediment car- tridges with activated carbon in its composition.
CHANGE COLLET AND O-RING 1. Remove the collet and o-ring from the fitting with a small screwdriver. Be careful not to scratch the inter- nal walls of the collet port. See Figures 27 & 28. 2. Clean collet port, lubricate and insert the o-ring seal into the bottom of the port.
Supply water pressure limits ..................................................... 40-100 psi (280-689 kPa) Supply water temperature limits ....................................................... 40-100 °F (5-40°C) Maximum total dissolved solids (TDS) .
Questions? Call The Kenrnore Water Line 1 =800=426=9345 or visit KenrnoreWater.corn 23.
Cause: The level of chlorine in your water supply exceeds maximum limits, and has destroyed the Reverse Osmosis mem- brane. Cause: The prefitter is no longer reducing chlorine from the water supply. iiii!ii iii i iiiiiii!!ii i iil ii ii!:: ii iii! ii iiiiiii i i ii!!iiii i i iii i!iiii iiiii i iliiiiil!i!i !i!i!i !i Cause: Postfitter expended.
i!!!i!!!iiiii!!!i!iii!i i!i!! i i !! !iii!i!iii!i i iiii! !!!!! i !!ii!iii!iiii!ii i!ii!iiiii i!i! i! i! i! !i!iiii!i!iii!i i i i i iiiiiiii!iiiiii!ii ! ! !!!ii!! i iiiii!iiiiii ii ! !iiiii ! i ! !i!!ii!ii!iiiiii!ii! i i i!ii! i i i Cause: Drain side of faucet airgap (3/8" black tub- Correction: Inspect and eliminate restriction or plug.
/ '%, 21-- 22 __2 4_---- 5 16__ _6 Manifold Housing PUSH-IN FITTINGS o-ring seal collet o©. T cZ) T 7 14 J"r i 1/4" red tubing 24 13 25 / Questions? Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater.
Key No. Part No. Description 1 7273337 Screw (6 req'd) 2 7281330 Washer (4 req'd) 3 7273345 Automatic Shut Off Cover 4 7272658 Check Valve 5 7115432 O-ring (2 req'd) 6 7272593 Cover, PW.
iiiiiiiiiiiiiiiiiiiiiiiiiiiiii!_ .... iiiiiiiiiiiiiiiiiiii iiiiiiiiiiiiiiiiiiii iiiiiiiiiiiiiiiiiiii iiiiiiiiiiiiiiiiiiii iiiiiiiiiiiiiiiiiiii iiiiiiiiiiiiiiiiiiii iiiiiiiiiiiiiiiiiiii iiiiiiiiiiiiiii.
Een belangrijk punt na aankoop van elk apparaat Kenmore ULTRAFILTER 650 625.38556 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Kenmore ULTRAFILTER 650 625.38556 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Kenmore ULTRAFILTER 650 625.38556 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Kenmore ULTRAFILTER 650 625.38556 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Kenmore ULTRAFILTER 650 625.38556 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Kenmore ULTRAFILTER 650 625.38556 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Kenmore ULTRAFILTER 650 625.38556 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Kenmore ULTRAFILTER 650 625.38556 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.