Gebruiksaanwijzing /service van het product MS2026C van de fabrikant Anritsu
Ga naar pagina of 24
Technical Data Sheet Introduction High Performance Handheld S-Parameters Anritsu introduces the MS202x/3xC VNA Master + Spectrum Analyzer , the industry’ s broadest frequency handheld solution to add ress cable , anten na, co mpone nt and si gnal an alys is need s in the fi eld: wi th freq uenc y cove rage fr om 5 kHz to 6/ 20 GHz.
2 Performance and Functional Highlights VNA Master • Broadband coverage of 5 kHz to 6/20 GHz • T rue 2-port V ector Network Analyzer (VNA) • Ultimate accuracy with 12-term error correction • U.
3 VNA Master Functional Specifications Definitions • All specifications and characteristics apply under the following conditions, unless otherwise stated: • After 30 minutes of warm-up time, where the instrument is in VNA Mode and left in the ON state.
4 These uncertainty curves show how frequency range, DUT Match, and cable loss impact worst-case uncertainty of round-trip cable loss measur ements. The uncertainty curves, separated by frequency range, are shown for DUT Match conditions of 20, 25, and 30 dB.
5 High Port Power OSLxx50 Calibration Components (N-Connectors) Corrected System Performance and Uncertainties: MS202x/3xC Model with 12-term SOL T calibration including isolation using either OSLN50 & OSLNF50 or OSLK50 & OSLKF50 Calibration Kits Pr ecision calibration standards come in a convenient configuration for field work.
6 Low Port Power OSLxx50 Calibration Components Corrected System Performance and Uncertainties: MS202x/3xC Model with 12-term SOL T calibration including isolation using either OSLN50 & OSLNF50 or.
7 High Port Power 3652A Calibration Kit (K-Connector) Corrected System Performance and Uncertainties : MS202x/3xC Model with 12-term SOL T calibration including isolation using 3652A Calibration Kit F.
8 Low Port Power 3652A Calibration Kit (K-Connector) Corrected System Performance and Uncertainties: MS202x/3xC Model with 12-term SOL T calibration including isolation using 3652A Calibration Kit Fre.
9 + Spectrum Analyzer Functional Specifications (Models MS2036/38C only) Freq ue ncy Freq uenc y R ang e 9 k Hz t o 20 GH z (us abl e to 0 H z), Pre amp 100 kHz to 20 G Hz T un ing Res olut io n 1 Hz Freq uenc y Re fer enc e Agi ng: ± 1.0 p pm /10 yea rs Ac cur acy : ± 0 .
10 + Spectrum Analyzer Functional Specifications (Models MS2036/38C only) (continued) Spu rs Res idua l S pur iou s Pre amp Of f (RF inp ut t er mina ted, 0 d B in put at tenu ati on) – 90 dB m 9 kH.
11 VNA Performance Capabilities (MS202x/3xC) Me asu re me nt P ara me te rs S 1 1 , S 2 1 , S 2 2 , S 1 2 , S d 1 d 1 , S c 1 c 1 , S d 1 c 1 , S c 1 d 1 Nu mb er o f Trac es Fou r: T R1, TR 2, TR3 , T R4 T r ac e For ma t Sin gle, Du al, T ri , Q uad.
12 + Spectrum Analyzer Performance Capabilities Me asu re me nt s Sma r t M eas urem ent s Fie ld Str eng th (us es ante nna cal ibr ati on tab les to mea sure dB m/m 2 o r d BmV/m) Oc cup ie d Ba ndw.
13 Measurement Options Specifications Time Domain (Option 0002) (includes Distance Domain Option 0501) The VNA Master can also display the S-parameter measurements in the time or distance domain using lowpass or bandpass processing analysis modes.
14 Bias T ee (Option 0010) For tower mounted amplifier tests, the MS20x/3xC series with optional internal bias tees can supply both DC and RF signals on the center conductor of the cable during measurements. For frequency sweeps in excess of 2 MHz, the VNA Master can supply internal voltage control from +12 to +32 V in 0.
15 High Accuracy Power Meter (Option 0019) Requires external USB power sensor . Co nd uc t p re ci se mea su re me nt s o f CW and di gi ta ll y m odu la te d t ra ns mi tt er s in th e f ie ld usi ng th is V NA M ast er so ft wa re mo de wit h a se pa ra te ly pu rc ha se d Anr it su US B po we r s en so r .
16 GPS (Option 0031), (Models MS2036/38C only) Requires external GPS antenna Built-in GPS provides location information (latitude, longitude, altitude) and Universal Time (UT) information for storage along with trace data so you can later verify that measurements were taken at the right location.
17 VNA Master General Specifications (MS202x/3xC) MI L- PRF -28 80 0F , C la ss 2 Env iro nm ent al Co ndi ti on s MS 202 x / 3xC T em per atur e, o per ati ng ( ºC) (3.8 .2 . 1 & 4.5 .5.1 4) P ass ed, –1 0 ºC to 55 ºC , Hu mid it y 8 5% T em per atur e, n ot o per ati ng ( º C) (3.
18 Ancillary Module extends Optical Fiber T esting to Distance-to-Fault The ODTF-1 module is primarily intended for field use by technicians and engineers responsible for the deployment and mai nten ance of re mote ra dio hea ds (RRH ), and ni cely co mple ment s the fie ld diag nost ic powe r of the V NA Maste r .
19 Fea tur e Be ne fi t Powe r ful dat a m ana gem ent too l fo r s tor ing and si ft ing th rou gh m eas ure ment re sult s M ST sim pli fi es t ra nsfe rs, pr int ing , an d ar ch ival of d isp lays and set ups Co nne ct to a PC usin g U SB2 .
20 MS202x/3xC Standard Accessories 10580-00220 VNA Master User ’s Guide 65729 Soft Carrying Case 2300-498 Master Software T ools CD ROM 633-44 Rechargeable Battery , Li-Ion, 6.6 Ah 40-168-R AC-DC Adapter 806-141-R Automotive Cigarette Lighter 12 V DC adapter 3-2000-1498 USB A-type to Mini USB B-type cable, 3.
21 Optional Accessories High Accuracy Power Sensor PSN50 High Accuracy Power Sensor , 50 MHz to 6 GHz MA24104A Inline High Power Sensor , 600 MHz to 4 GHz, T rue RMS MA24106A High Accuracy Power Senso.
22 Ordering Information (continued) Par t Nu mb er Freq ue ncy Ra nge Wave gui de T y pe Co mp at ib le Flan ge s 1/8 O f f set Sh or t 3/ 8 O f fs et Sh or t Pre ci sio n Loa d Coa x ial to Uni ver sa l Wave gui de Ada pt er [1] 23 UM70 24UM 70 26 UM70 35UM 70N 5.
23.
11410-00548, Rev. B Printed in United States 2010-09 ©2010 Anritsu Company. All Rights Reserved ® Anritsu All trademarks are registered trademarks of their respective companies. Data subject to change without notice. For the most recent specifications visit: www.
Een belangrijk punt na aankoop van elk apparaat Anritsu MS2026C (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Anritsu MS2026C heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Anritsu MS2026C vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Anritsu MS2026C leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Anritsu MS2026C krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Anritsu MS2026C bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Anritsu MS2026C kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Anritsu MS2026C . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.