P/N 1010745 Rev . H 03/07 V ARIETY STEAMER Models VS-350 Owner ’ s Man ual M A N U F A C T U R I N G N U M B E R S : 9100700 9100710 9100712 9100714 9100720 A S D L I S T E CM O I N N I T A T C T I .
V ARIETY STEAMER 2 P/N 1010745 Rev . G 03/06 General The V ariety Steamer produces steam using plain tap water for quick heating and reconstituting of food items.
3 V ARIETY STEAMER P/N 1010745 Rev . G 03/06 Service/T echnical Assistance If you experience any problems with the installation or operation of your unit, contact your local Roundup Authorized Service Agency . They can be found in the service agency directory packaged with the equipment.
V ARIETY STEAMER 4 P/N 1010745 Rev . G 03/06 Throughout this manual, you will find the following safety words and symbols that signify important safety issues with regards to operating or maintaining your V ariety Steamer . W ARNING GENERAL W ARNING. Indicates informa- tion important to the proper operation of the equipment.
5 V ARIETY STEAMER P/N 1010745 Rev . G 03/06 • W ARNING ELECTRICAL SHOCK HAZARD. F AILURE TO FOLLOW THESE INSTRUCTIONS COULD RESUL T IN SERIOUS INJUR Y OR DEA TH. - E lectrical ground is required on this appli- ance. - Do not modify the power supply cord plug.
V ARIETY STEAMER 6 P/N 1010745 Rev . G 03/06 SPECIFICA TIONS Electrical Ratings Shipping Weight 63 lbs. (28 kg) Electrical Cord & Plug Configurations CAUTION All electrical connections must be in accordance with local electrical codes and any other appli- cable codes.
7 V ARIETY STEAMER P/N 1010745 Rev . G 03/06 Unpacking 1. Remove unit and all packing materials from ship- ping carton. 2. The unit should contain the following: • Owner ’s Manual • Authorized S.
V ARIETY STEAMER 8 P/N 1010745 Rev . G 03/06 CAUTION All electrical connections must be in accordance with local electrical codes and any other appli- cable codes. W ARNING ELECTRICAL SHOCK HAZARD. F AILURE TO FOLLOW THE INSTRUCTIONS IN THIS MANUAL COULD RESUL T IN SERIOUS INJUR Y OR DEA TH.
9 V ARIETY STEAMER P/N 1010745 Rev . G 03/06 STEAMING GUIDE The V ariety Steamer makes it possible to expand a menu with just one piece of equipment. The V ariety Steamer produces a super-heated dry steam. This steam penetrates the product until the product’ s temperature matches the steam temperature.
V ARIETY STEAMER 10 P/N 1010745 Rev . G 03/06 OPERA TION Operator Controls ROCKER SWITCH (POWER ON/OFF) When the Rocker Switch (Power On/OFF) is in the ON position, the Control Board is activated. If the genera- tor temperature is below the factory preset setpoint, power is applied to the generator until the setpoint temperature is reached.
1 1 V ARIETY STEAMER P/N 1010745 Rev . G 03/06 UP & DOWN ARROW BUTTONS The actual generator temperature can be viewed by depressing the UP arrow button (Figure 3) at any time. The arrow buttons are used with the other buttons to program the unit (see the Programming section of this manual for more information).
V ARIETY STEAMER 12 P/N 1010745 Rev . G 03/06 General Programming CYC (T otal Cycle Time) refers to the total amount of cooking time set for the product (Figure 4). RA TE (Shot Interval Time) is the time set between each shot of steam during a complete cycle (Figure 5).
13 V ARIETY STEAMER P/N 1010745 Rev . G 03/06 UP DOWN PR OGRA M SING LE SHO T 1 2 3 4 S H O T Figure 6. SHOT Mode on Menu 1 UP DOWN PR OGRA M SING LE SHO T 1 2 3 4 0 0 : 1 0 Figure 7. Programming Mode SINGLE SHOT Button Used for Saving All Changed Settings.
V ARIETY STEAMER 14 P/N 1010745 Rev . G 03/06 the steam generator hole. T ake a suitable 1/16” punching tool (such as a paperclip) and fully insert it through all 18 orifices in the black manifold as well as through the 10 orifices in the spray tube.
15 V ARIETY STEAMER P/N 1010745 Rev . G 03/06 4. Wearing protective eyewear and gloves, pour delimer solution (not supplied) onto the generator surface (Figure 8). Be sure to follow the delimer manufacturer ’s directions for proper mixture and use. Figure 8.
V ARIETY STEAMER 16 P/N 1010745 Rev . G 03/06 Diagnostics The four-channel controller is also equipped with diag- nostic features. Listed under each drawing is a brief description of the particular feature. Also contained in the control housing mounted on the control board are diagnostic LED’s.
17 V ARIETY STEAMER P/N 1010745 Rev . G 03/06 UP DOWN PR OGRA M SING LE S HOT 1 2 3 4 SHOT PWR (Power) will be displayed when the supply volt- age is lower than 160 V olts AC or above 265 V olts AC. PWR UP DOWN PR OGRA M SING LE S HOT 1 2 3 4 SHOT OPEN will be displayed when the thermocouple is “open” or not installed correctly .
V ARIETY STEAMER 18 P/N 1010745 Rev . G 03/06 T echnical Theory of Operation When the Rocker Switch (power On/Off) is ON, line voltage flows to the primary side of the step down transformer . The transformer ’s secondary side supplies 12 and 24 V AC to the Control Board.
19 V ARIETY STEAMER P/N 1010745 Rev . G 03/06 TROUBLESHOOTING W ARNING T o avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equip - ment should be performed by qualified service personnel. The unit should be unplugged when servicing, except when electrical tests are required.
V ARIETY STEAMER 20 P/N 1010745 Rev . G 03/06 TROUBLESHOOTING (continued) Problem Prossible Cause Corrective Action Unit heats but there is little or no steam produced and/or The product requires more steaming than usual (continued). Improper water pressure to unit.
21 V ARIETY STEAMER P/N 1010745 Rev . G 03/06 WIRING DIAGRAM # BLK RED BLK BRN ORG GRN YEL T10 T9 T8 T7 T6 T5 T1 T2 T3 T4 4- 3+ 1 2 RED YEL BLUE ORG BLK # BRN # # # T11 BLK BLK WHT BLK WHT 230V SOLENOID 4 2 WHT 6 8 5 1 10 TRANSFORMER BLK WHT CORD BLOCK POWER TERMINAL GRN GND SWITCH POWER 1 2 4 5 # # BOARD SWITCH BOARD S.
V ARIETY STEAMER 22 P/N 1010745 Rev . G 03/06 41 39 40 42 21 33 22 47 29 48 27 24 25 26 28 49 1 1 10 51 52 50 9 55 53 54 7 15 14 13 12 36 23 1 8 37 38 3 5 8 19 45 44 46 17 18 16 58 59 2 4 6 Available .
23 V ARIETY STEAMER P/N 1010745 Rev . G 03/06 REPLACEMENT P ARTS (continued) Item Part Description Qty . No. Item Part Description Qty . No. 1 001 1539 T op Housing Assy . (Jumbo) 1 2 7000404 Generator Manifold (incl. #66 & 67) 1 3 0200187 O-Ring 1 4 0020947 Drip Tray Assy .
LIMITED W ARRANTY Equipment manufactured by Roundup Food Equipment Division of A.J. Antunes & Co. has been con- structed of the finest materials available and manufactured to high quality standards.
Een belangrijk punt na aankoop van elk apparaat Antunes, AJ VS-350 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Antunes, AJ VS-350 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Antunes, AJ VS-350 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Antunes, AJ VS-350 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Antunes, AJ VS-350 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Antunes, AJ VS-350 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Antunes, AJ VS-350 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Antunes, AJ VS-350 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.