Leica M series Manual 2 General Instructions Safety concept Before using your microscope for the first time, please read the "Safety concept" br ochure included with your instrument. It contains addi - tional information about handling and care .
Leica M series Manual 3 Safety concept The individual modules of the Leica M stereo - microscopy series include an interactive CD-ROM with all r elevant user manuals in 20 other languages. Keep it in a safe place, and readily ac cessible to the user .
Leica M series Manual 4 Symbols used W arning of a danger This symbol indicates especially impor - tant information that must be read and complied with.
Leica M series Manual 5 Safety regulations Description The individual modules fulfill the highest requirements for observation and documen - tation of Leica stereo microscopes of the M series.
Leica M series Manual 6 Safety regulations (con tinued) Repair , ser vice work See “Safety concept” booklet ★ Only original Leica M icrosystems spare ★ parts may be used. Before opening the instruments, switch off ★ the power and unplug the pow er cable.
Leica M series Manual 7 Safety regulations (con tinued) Direct contact with eyepieces can be a poten tial transmission path for bacterial and viral infec - tions of the eye. The risk can be kept to a minimum by using personal eyepieces for each individual or detachable eyecups.
Leica M series Manual 8 Safety regulations (con tinued) Supply unit Always unplug the supply unit from the power supply: When installing and disassembling the ★ lamp housing Before opening the lamp .
Leica M series Manual 9 T able of C ontents T ransmitted-light Base TL BFDF: Befor e First U se 3 0 T ransmitted-light Base TL BFDF 3 1 TL RC™ / TL RCI™ 3 2 IsoPro™ Manual Cr oss-stage: Assembly.
Leica M series Manual 10 Eyepiec e s Magnification F ac tors of the Eyepiec es 5 8 Health Notes 5 9 Dioptric correction 6 0 Dioptric Correction and P arfocality 6 1 Graticules 6 2 Photograph y & .
Leica M series Manual 11 Acc essorie s Leica PSC C ontroller 9 5 Dimensional Drawing s Leica M125 / M165 C 9 7 Leica M205 C 10 1 Leica LED5000 MCI 10 4 Leica LED5000 RL 10 5 Specications for the Ba.
Leica M series Manual 12 T he L eica M S eries.
Leica M series Manual 13 Congr atula tions! Congra tulations on obtaining your new Leica M series stereomicroscope . W e are convinced it will exceed your expectations, as never before have we applied our decades of experience in the areas of optics, mechanical engineering and ergonomics in such an uncompr omising manner .
Leica M series Manual 14 A Step T owar ds Infinity Ever since their introduction by Horatio S. Greenough, stereomicroscopes have worked according to the optical principles based primarily on Ernst Abbe's research.
Leica M series Manual 15 The Electronics: Comf ort, Con v enience and Safety for y our Experiments Never before have electronics been used as extensively in a Leica series as in the new M series . Optics carrier , tripod, base and illu - minator are all connected using electrical contacts—which provides a number of advan - tages.
Leica M series Manual 16 Have a special r equest? Let us know! Leica Microsystems enjo ys an exceptional repu - tation when it comes to devising customer- specific solutions. If you have a special request that cannot be met with standard parts, contact your Leica consultant .
Leica M series Manual 17 Leica engineers were careful to ensure that the new M series—like its predecessors—remains compatible with existing series.
Leica M series Manual 18 On W e Go If your new Leica microscope has already been assembled and commissioned by your Leica consultant, click her e to skip through the instal - lation instructions and go directly to the Quick Start Guide on page 46 .
Leica M series Manual 19 Assembly.
Leica M series Manual 20 The first step is to c onnect the focusing column of the M series to the corresponding base . T ools used Hex socket screw driver , 3 mm ★ Assembling the column adapter 1. Securely install the column adapter on the column using the four included screw s.
Leica M series Manual 21 T ools used Hex socket screw driver , 4 mm ★ Assembling the optics carrier 1. Place the optics carrier on the focusing column so that the screw fit int o the thread provided and the lug fits int o the groov e. 2. Pr ess the optics carrier backwards to the focusing column and scr ew it in place using your other hand.
Leica M series Manual 22 T ube All intermediate tubes that fit between the optics carrier and the binocular tube are fitted in the same manner . T ools used No tools requir ed. ★ Prepara tions 1. Unscrew the positioning screw and r emove the protective co ver .
Leica M series Manual 23 Ey epieces T ools used No tools requir ed. ★ Magnification range Y ou can ex tend the overall mag nification range using available 10×, 16×, 25× and 40× wide - field eyepieces for persons w earing glasses. Prepara tion 1.
Leica M series Manual 24 Objective T ools used No tools requir ed. ★ Prepara tion 1. Remove the protective cap on the optics carrier by turning it. Attaching the objective Hold the objective firmly during assem - bly and disassembly so that it does not fall onto the stage plate.
Leica M series Manual 25 Prepara tions Hold the objectives firmly during assembly and disassembly so that they do not fall onto the stage plate . Move the drive housing all the way upwards ★ and remove the optics carrier , if the carrier has already been installed.
Leica M series Manual 26 Objective Nosepiece – A djusting Parfocality The following procedure only has to be carried out once. Afterwards, both objectives are par fo - cal, meaning that the specimen remains in focus when the objective nosepiece is rotated .
Leica M series Manual 27 T ools Hex socket screw driver , 2.5 mm ★ Preparing the A X carrier Before the AX carrier is installed, it may first have to be prepared for the optics carrier to be used (Leica M125, M205 C or M165 C). 1. Check the switch position.
Leica M series Manual 28 T ools Hex socket screw driver , 4 mm ★ Philips screwdriv er ★ Once the AX carrier has prepared for the corre - sponding optics carrier , it can be installed. 1. Move the slide of the AX carrier into mid position. 2. Install the AX carrier on the focusing column.
Leica M series Manual 29 T ransmitted-light Base TL ST Unpacking the base The base is deliver ed with the adapter plat e installed. M ake sure the devices are unpacked on a flat , sufficiently dimensioned , and non-slip sur face. Focusing driv e and column 1.
Leica M series Manual 30 Removing the transport anchors Before you can use the transmitted- light base for the first time, it is abso - lutely necessar y to remove the two transpor t anchors as follows .
Leica M series Manual 31 T ransmitted-light Base TL BFDF Standard delivery The base is deliver ed with the adapter plat e installed. The selec ted stage (IsoPro™ cross- stage or standard stage 10 447 269), and the focusing drive will ha ve to be mount ed later .
Leica M series Manual 32 The base is deliver ed with the adapter plat e installed. The selec ted stage (IsoPro™ cross- stage or standard stage 10 447 269), and the focusing drive will ha ve to be mount ed later . Ensure that the instruments are unpacked on a level, adequa tely sized, and nonskid underlay .
Leica M series Manual 33 IsoPro™ Manual Cr oss-stage: Assembly Before the IsoPr o™ cross-stage is mounted to the base, the axis containing the control buttons is attached either on the left or the right side of the cross-stage.
Leica M series Manual 34 IsoPro™ Manual Cr oss-stage: Assembly (continued) 1. T ake the glass plate fr om the cr oss-stage and turn it around. 2. Change the gear rod from the left to the right-hand side. Control assembly 1. T ake the glass plate fr om the cr oss-stage and turn it around.
Leica M series Manual 35 IsoPro™ Manual Cr oss-stage: Assembly (continued) 3. Screw the cross-stage evenly onto the thr ee threaded holes. 4. Push the cross-stage all the way back towar ds the column. 5. Reinsert the glass plate back into the stan - dard stage.
Leica M series Manual 36 Basics The transmitted light bases of the TL series ( TL BFDF , TL RC™, TL RCI™) are supplied with an installed extension plate. The selec ted stage (IsoPro™ cross-stage or standard stage 10 447 269), and the focusing drive will have to be mounted later .
Leica M series Manual 37 3. Remove the two M3 screws and the holder from the cross-stage . 4. Remove the two M4 screws and the sleeve from the cross-stage . 5. Remove the four shock-absorbing cartons from the cross-stage . After removal, keep all the trans - port anchors in the plastic bag for future transport.
Leica M series Manual 38 IsoPro™ Mot orized Cross-stage: Assembly (c ontinued) The bases The TL BFDF , TL RC™ and RCI™ transmitted light bases can be equipped with three different stages: standard stage, manual and IsoPro™ automated cross-stage.
Leica M series Manual 39 IsoPro™ Mot orized Cross-stage: Assembly (c ontinued) Cross-stage for X - Y Stage Control Module 1. Plug the CTL2 plug of the cross-stage motor into one of the three available C TL2 inter - faces. 2. Plug the CTL2 plug of the Leica PSC contr ol - ler into another CTL2 inter face.
Leica M series Manual 40 The new Leica M-series features extensive encoding with which various microscope data and settings can be read out, transferred to the PC and reproduc ed later .
Leica M series Manual 41 The integrated cable duct in the column enables a neat cable layout around the microscope. F or example, the USB or FireW ire cables of the camera can be stow ed in the cable duct. Feeding the cables 1. Unscrew the three screws on the cable duct.
Leica M series Manual 42 Cables: Diagram TL RCI™ DCI Controlbo x PSC PC USB (Connect to fr ee CTL2-port on last footswitch.) Connector from Cr oss Stage Smart Move Pow er/USB LED5000 RL LED5000 MCI™ Footswit ch 1 Footswit ch 2... Please use the Leic a Application Suite to configur e the functions of the system.
Leica M series Manual 43 The L eica LED5000 MCI™ (f or "Multi C ontrast Illumination") is installed using t wo screws. For optimum accessibility, the optics carrier should be remov ed during installation (see page 15 .) Constrain ts The Leica LED5000 MCI™ cannot be used together with the objective nosepiece.
Leica M series Manual 44 Under certain cir cumstances, the light source must not be moved along with the optics carrier . A typical example is multifocus images in which the Z-stack changes while the angle of incidence of the light must remain the same.
Leica M series Manual 45 The ring illuminator , the Leica LED5000 RL ("Ring Light"), is installed on the objective using a single scr ew . It has been optimized for a work - ing distance between 60 and 70 mm. Constrain ts The Leica LED5000 RL can be used in conjunc - tion with the planapochromat 1× and planapo - chromat 0.
Leica M series Manual 46 Q uick Star t Guide.
Leica M series Manual 47 The F astest Route to Suc cess Y our Leica stereomicroscope has been delivered in completely assembled condition by your Leica par tner , and naturally you want to get right to work. Ther efore , your next step should be to study the Q uick Star t Guide, which outlines the most important steps at a glance.
Leica M series Manual 48 Overview of an M series Microscope 1 Magnification changer (zoom) 2 Switch click stops on/off 3 Coarse/fine focusing 4 F astening screw for the binocular tube (or acc essor.
Leica M series Manual 49 The C orrect Interpupillary D istance The interpupillary distance is correctly set if you see a single circular image field when look ing at a specimen. If y ou ar e still a novice microscope user , you may need a shor t time to become accustomed to this.
Leica M series Manual 50 If you wear glasses: 1. Hold the eyepiece firmly and rotate the eyecups counter clockwise t owards the rear , as other wise the viewing distance is too great. 2. If an eyepiece is equipped with the inte - grated dioptric c orrection, turn the value to the "0" mark.
Leica M series Manual 51 F ocusing F ocusing raises or lowers the stereomicroscope using the focusing drive. The specimen detail is brought into sharp focus as soon as it is in the focal point of the objective. The focusing drive can be operated either ★ left- or right-handed.
Leica M series Manual 52 Adjusting the r esistance of the focus driv e Adjusting the resistance Is the focus movement too loose or too tight? Does the outfit tend to slide downwards? The resistance can be adjusted individually depend - ing on the equipment weight and personal prefer ences as follow s: 1.
Leica M series Manual 53 Changing the magnification (zoom) All M series microscopes have an integrated zoom. The name indicates the zoom range cover ed: Leica M125 = 16.5:1 ★ Leica M165 C = 16.5:1 ★ Leica M205 C = 20.5:1 ★ The rotar y knob for the z oom can be used either left or right-handed.
Leica M series Manual 54 The zoom butt on can optionally be operat ed either with or without ratchet steps. Continu - ous z oom is possible when the ratchet steps are disabled, which many users find convenient. On the other hand, when the ratchet steps are enabled, photographs , measurement results etc.
Leica M series Manual 55 Parfocality: More Comf or t and Con venience for Y our W ork All Leica stereomicroscopes are parfocally matched, meaning that you can view a focused specimen from the lowest to the highest magni - fication without having to refocus .
Leica M series Manual 56 The iris diaphragm in the optics carrier of your M series microscope has the same purpose as those in a camer a shutter: it regulates the avail - able light, which changes the depth of field. The "depth of field" is the area of a specimen that is brought into sharp f ocus.
Leica M series Manual 57 E y epiec es.
Leica M series Manual 58 Magnification F ac tors of the Ey epieces An eyepiece not only makes it possible to look passively into the micro - scope, but also has a critical effect on the maximum magnification. The magnification factor is between 10x and 40x.
Leica M series Manual 59 Health Notes Pot ential sources of infection Direct contact with eyepieces is a potential transmission method for bacterial and viral infections of the ey e. The risk can be kept to a minimum by using individual eyepieces or detachable eyecups.
Leica M series Manual 60 All Leica eyepieces are also available with built-in dioptric correction, allowing the micro - scope to be used without glasses ev en by those with vision problems. The correction comprises ±5 diopter settings. Using the Dioptric Corr ection 1.
Leica M series Manual 61 Adjusting 1. Set the dioptric correction for both eyepieces to "0" . 2. Select the lowest magnification and focus on a flat specimen. 3. Select the highest magnification and read - just the sharpness. 4. Select the lowest magnification again, but do not look into the eyepiec es.
Leica M series Manual 62 Graticules 2. Clamp the graticule on the insert, applying moderate pressure. Ensure that the gr ati - cule fits tightly . 3. Screw the insert and graticule firmly in to place and replace the ey epiece in the tube.
Leica M series Manual 63 Photogr aph y & V ideo.
Leica M series Manual 64 F or most microscope users, digital documen - tation has become an invaluable par t of their work. Research results can be presented in an attractive manner ; measurements on .
Leica M series Manual 65 Photo tubes and C-mounts Application All Leica DFC cameras are equipped with a standardized C-mount inter face. In turn, the C-mount adapter for the respective trinocular tube is connected t o this int er face.
Leica M series Manual 66 T rinoc ular video/phototube 50% Use With its third beam path, the trinocular video/ phototube 50% enables you to simultaneously view and photograph a specimen. The available light is divided as follows: 50% is available for the two ey epieces.
Leica M series Manual 67 Use With its third beam path, the trinocular video/ phototube 100% enables you to either view or photograph a specimen. This means that 100% of the light is available to one or the other beam path. The other beam path remains opaque or black.
Leica M series Manual 68 Microsc ope C arrier.
Leica M series Manual 69 Stereoscopic viewing A stereoscopic view is required for examining spatial objects. For this purpose, the micro - scope carrier AX must be brought to its home position. 1. Unscrew the clamping scr ew . 2. Push the microscope into the home posi - tion (mid position) to obtain a spatial view and tighten the clamping screw .
Leica M series Manual 70 Parallax -free images The parallax-free imaging produces more precise results in photography , measuring and polarization. 1. Unscrew the clamping scr ew . 2. Push the microscope towards the lef t as far as it will go and tighten the clamping screw .
Leica M series Manual 71 Use The objec tive nosepiece enables you to switch between two objectives using just one hand movement , f or example bet ween a 1× and a 2× planapochromat.
Leica M series Manual 72 Objec tiv es and optic al ac c essories.
Leica M series Manual 73 The Differ ent T ypes of Objec tives T o meet the various requirements regarding imaging properties, there is a choice of high- quality interchangeable planachromatic and planapochromatic objectives and also lower- priced inter changeable achromatic objectives.
Leica M series Manual 74 Bases.
Leica M series Manual 75 T ransmitted-light Base TL ST : Con trols 1 Adapter plate for easy assembly of focusing drives 2 Removable glass plat e 3 Controller for light int ensity 4 Adjustment for de.
Leica M series Manual 76 T ransmitted-light Base TL ST : Operation Light intensity contr ol The left control adjusts the intensity of the 12 V/20 W halogen illumination. 1. Switch on the illumination of the base at the power switch. 3. F ocus on the specimen.
Leica M series Manual 77 Changing the Halogen Lamp Before you change the lamp , it is abso - lutely nec essary to unplug the pow er plug from the base to prevent the risk of elec - tric shock! The halogen lamp becomes ver y hot during operation. Therefore , to avoid being burned, let the base cool off for approx.
Leica M series Manual 78 T ransmitted-light Base TL BFDF: C ontrols 1 Adapter plate for easy assembly of focusing drives 2 Standard stage 10 447 269 3 Button to toggle between bright field and dark .
Leica M series Manual 79 Light intensity contr ol Please observe the user manual—in particular , all safety regulations—fr om the manufacturers of the light guide and cold light source . Switch on the cold ligh t source according to ★ the manufac turer's user manual and adjust the brightness.
Leica M series Manual 80 TL RC™ / TL RCI™: Controls V ertical column - transmitted-light base adapt er plate 1 Heat sink of the integrat ed halogen illumina - tion (only TL RCI™) 2 Extension pla.
Leica M series Manual 81 TL RCI™: The Deflec tion Mirror Inv erted world? Depending on the properties of the specimen (refractive index of the environment) and the perception of the viewer , it is possible that the switches described below for positive and inverted relief contrast are to be operated in reverse .
Leica M series Manual 82 TL RCI™: Color In tensity and T emperatur e 1 Potentiomet er for controlling the C CIC™ (Constant C olor Intensity Control) illumina - tion intensity 2 Potentiomet er for .
Leica M series Manual 83 Setting the relief contrast The two switches on the left side of the trans - mitted-light base TL RC™/TL RCI™ activate two built-in flaps. The outer switch (1) controls the inverted relief contrast, and the inner switch (2) adjusts the positive relief c ontrast.
Leica M series Manual 84 TL RCI™: Methods in T ransmitted Light V ertical bright-field illumination Suitable for stained amplitude specimens with sufficient contrast. The light beams are deflected vertically through the specimen. This results in an accurate bright field with maximum brightness.
Leica M series Manual 85 TL RCI™: Relief Images Starting position 1. Push the deflection mirror all the way back towar ds the column. 2. T urn the deflec tion mirr or into the notch position at an angle of 45°. Positiv e relief contr ast Suitable for semitransparent and transparent specimens.
Leica M series Manual 86 Dynamic relief contrast Suitable for semitransparent and transparent specimens. By tilting the deflection mirror slightly , you can move the gaps over the entire field of view and quickly toggle bet ween positive and negative relief images.
Leica M series Manual 87 Filters f or TL RC™ and TL RCI™ The transmitted-light bases TL RC™ and TL RCI™ can be equipped with up to three filters—available as accessories—simultane - ously . By customer request, the filters are also available as one- off items.
Leica M series Manual 88 IsoPro™ (Non-mot orized): C ontrols Operating the cross-stage IsoPr o™ 1. T o move the stage in X direction, rotate the outer knob.
Leica M series Manual 89 IsoPro™ (Mot orized): C ontrols 1 Motorized cross -stage Leic a IsoPro ™ 2 Housing with motorization 1 Sub-D interface for Leic a SmartMove™ 2 3 CTL2 interfaces 3 USB in.
Leica M series Manual 90 S y st em Illumina tion.
Leica M series Manual 91 Use The L eica LED5000 MCI™ (f or "Multi C ontrast Illumination") is a universal high-output illu - minator . Three groups of 3 LEDs each can be arranged as desired around the specimen. The targeted contr ol of the LEDs enables various illumination scenarios to be implement ed.
Leica M series Manual 92 Using the ke yboard Use the ★ key to switch the illumination on or off . Use the "+" and "–" keys to adjust the ★ brightness in 10 increments . T ouch either of the two butt ons to adjust the intensity in small increments.
Leica M series Manual 93 Leica LED5000 RL Use The Leica LED5000 RL ("Ring Light") generates a ver y bright and homogenous incident light. It has a diameter of 80 mm and illuminates the specimen with 48 LEDs that can be switched on and off completely or in various combinations.
Leica M series Manual 94 A cc essories.
Leica M series Manual 95 Leica PSC Con troller Use The Leica PSC controller gives you precision control of the Leica IsoPr o™ motorized cross- stage.
Leica M series Manual 96 Dimensional D ra wings.
Leica M series Manual 97 Leica M125 / M165 C 120 120 277 24 400 455 292 217 120 120 277 24 400 455 292 217 120 120 277 24 400 455 292 217 Leica M125 / M165 C with incident light base and new focusing .
Leica M series Manual 98 Leica M125 / M165 C (continued) 340 430 85 154 356 154 292 217 106 431 537 340 430 85 154 356 154 292 217 106 431 537 340 430 85 154 356 154 292 217 106 431 537 Leica M125 / M.
Leica M series Manual 99 Leica M125 / M165 C (continued) 385 154 340 390 440 95 154 116 431 547 292 217 385 154 340 390 440 95 154 116 431 547 292 217 385 154 340 390 440 95 154 116 431 547 292 217 Le.
Leica M series Manual 100 Leica M125 / M165 C (continued) 497 292 217 187 154 max. 370 X = +-75 mm 370 95 300 249 Y = +-50 mm 116 431 547 497 292 217 187 154 max.
Leica M series Manual 101 Leica M205 C 370 154 340 390 90 154 292 217 116 431 547 370 154 340 390 90 154 292 217 116 431 547 370 154 340 390 90 154 292 217 116 431 547 Leica M205 C with transmitted-li.
Leica M series Manual 102 Leica M205 C (continued) 385 154 340 390 440 95 154 116 431 547 292 217 385 154 340 390 440 95 154 116 431 547 292 217 385 154 340 390 440 95 154 116 431 547 292 217 Leica M2.
Leica M series Manual 103 Leica M205 C (continued) 497 187 154 max. 410 X = +-75 mm 370 95 300 249 Y = +-50 mm 292 217 116 431 547 497 187 154 max. 410 X = +-75 mm 370 95 300 249 Y = +-50 mm 292 217 116 431 547 497 187 154 max.
Leica M series Manual 104 Leica LED5000 MCI 132 275.3 157 83.5 112 45 112 90 45 36 22 132 275.3 157 83.5 112 45 112 90 45 36 22 132 275.3 157 83.5 112 45 112 90 45 36 22 Leica LED5000 MCI (dimensions .
Leica M series Manual 105 Leica LED5000 RL 120 ø70 30 153 153 ø80.
Leica M series Manual 106 Specific a tions f or the Bases.
Leica M series Manual 107 T ransmitted-light Base TL ST Light source Halogen lamp 12V/20W Quick illuminant change Ye s Illuminated area 50 mm Po wer supply unit Input voltage 100 – 240 V~, frequency 50 – 60 Hz energy consumption 30 W max., ambient temperatur e 10–40 °C Connections Po wer plug , power switch W eight 7.
Leica M series Manual 108 T ransmitted-light Base TL BFDF Light source Ex ternal via cold light source Illuminated area 40 mm Connections Connection for cold light guide , active f=10 mm, end tube f=13 mm W eight 5.
Leica M series Manual 109 TL RC™ / TL RCI™ Leica TL RC™ Leica TL RCI™ Light source External via cold light source Halogen lamp 12V/20W Quick illuminant change – Ye s Illuminated area 35 mm 35 mm Po wer supply unit – 100 – 240 V~, frequency 50 – 60 Hz energy consumption 30 W max.
Leica M series Manual 110 IsoPro™ Mot orized XY Stage Compatibility Leica inciden t light base and TL bases (TL BFDF , TL RC™, TL RCI™) Stage size (L × W × H) 335.5 mm × 370 mm × 41.5 mm Tr a v e l 152 mm × 102 mm (6" × 4") Speed X,Y 30 mm/s Motor resolution X,Y 0.
Leica M series Manual 111 Appendix.
Leica M series Manual 112 Calculating the T otal Magnific ation and F ield of View Diameter Paramet er MO Magnification of objective ME Magnification of eyepiece z Magnification changer position q T ube factor , e.g . 1.5× for coaxial incident light, 1.
Leica M series Manual 113 Care , Maintenance, C ontac t Persons W e hope you enjoy using your high-per for - mance microscope. Leica microscopes are renowned for their r obustness and long ser vice life.
Leica M series Manual 114 Care , Maintenance, C ontac t Persons (c ontinued) Protection from dirt Dust and dir t will affect the qualit y of your results. Put a dust cover over the instrument when ★ it will not be used for a long time. Use dust caps to protect tube openings, ★ tubes without eyepieces , and eyepieces.
Een belangrijk punt na aankoop van elk apparaat Leica M205 C (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Leica M205 C heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Leica M205 C vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Leica M205 C leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Leica M205 C krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Leica M205 C bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Leica M205 C kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Leica M205 C . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.