Gebruiksaanwijzing /service van het product LMBV-42RMP van de fabrikant Lennox Hearth
Ga naar pagina of 16
1 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INST ALLA TION INSTRUCTIONS 42" B-VENTED GAS APPLIANCES P/N 850,041M REV. A 02/2007 Millivolt Models Electronic Models LMBV-42RMN LMBV -42REN LMBV-42RMP FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors or liquids in the vicin- ity of this or any other appliance.
2 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. TABLE OF CONTENTS Introduction ..................................... page 2 General Information ......................... page 2 Massachusetts and New York Requirements ...............................
3 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea.
4 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. CLEARANCES Minimum clearance to combustibles for the ap- pliance is as follows: sides and back - 0" (0 mm), floor - 0" (0 mm), adjacent wall - 0" (0 mm), ceiling - 64" (1625 mm). Venting Gas Vent Rule – Gas vent caps are not permit- ted within 8 feet (2.
5 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. FRAMING SPECIFICATIONS Figure 4 Figure 5 Figure 6 Framing Dimensions Note: All framing dimensions calculated for 1/2" dry wall at the appliance face. If sheathing the chase or finishing with other thickness materials, calculations will need to be made.
6 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. All appliances are equipped with a gas flex line and shutoff valve attached directly to the gas control valve.
7 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 11 Step 5. Field Wiring – Refer to Section A for millivolt appliances and Section B for electronic appliances. A. Millivolt Wiring – The gas valve has been set in place and has been pre-wired at the factory.
8 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 14 Note: Supply wires may be alternatively connected to the outlet using the screw terminals, however the black supply wire must be wired to a terminal that is opposite (across the outlet) the point where the white supply wire is connected.
9 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Replace logs if removed for pilot inspection. To light the burner; turn “ON” the remote wall switch and rotate the gas valve control knob counterclockwise to the “ON” position (“ON” will be to the left hand side of the valve).
10 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. When satisfied that the appliance operates properly, proceed to finish the installation. Leave the control knob/lever in “ON” position and turn the remote switch “OFF.” Replace the refractory access panel.
11 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Fireplace Opening Spacer Finished Wall Header 1 2 3 4 5 6 7 8 9 10 11 12 9 10 11 12 Combustible Mantel Clearances Inches Min. Height of Mantel Above Fireplace Opening Max.Length of Mantels Three mantels are shown (dark gray elongated rectangles)- one, 1 ¹⁄₂ in.
12 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Gas Conversion Kits In Canada THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN1-B149.
13 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Step 5. Attach manometer to the manifold side pressure test fitting and verify manifold pressure reads 3.5 inches water column (0.87 kPa) for natural gas, and 10.0 inches water column (2.49 kPa) for propane gas.
14 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. NOTE: THIS PAGE INTENTIONALLY LEFT BLANK..
15 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. NOTE: THIS PAGE INTENTIONALLY LEFT BLANK..
16 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Printed in U.S.A. © 2006 by Lennox Hearth Products P/N 850,041M REV. A 02/2007 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.
Een belangrijk punt na aankoop van elk apparaat Lennox Hearth LMBV-42RMP (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lennox Hearth LMBV-42RMP heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lennox Hearth LMBV-42RMP vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lennox Hearth LMBV-42RMP leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lennox Hearth LMBV-42RMP krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lennox Hearth LMBV-42RMP bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lennox Hearth LMBV-42RMP kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lennox Hearth LMBV-42RMP . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.