EP A W ood -Bu rni ng Fir epl ace s P/N 5 060 23- 13 RE V . A 0 2/2 011 Brentwood L V MODEL Brentwood™ L V This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system. Please read and understand these instructions before beginning your installation.
W ARNING T o avoid the risk of damaging fireplace materials and increas- ing the risk of fire, do not use the fireplace to cook or warm food. IMPORT ANT! GENERAL SAFETY PRECAUTIONS. READ AND UNDERST AND THESE SAFETY R U L E S B E F O R E Y O U R F I R S T F I R E .
T ABLE OF CONTENTS SAFETY RULES and Specifications for Mobile or Manufactured Home Installation ......................... Page 2 Introduction ...................................... Page 3 Parts Required ................................. Page 3 Optional Equipment .
Building a Fire (starting and maintaining a fire) T o start a fire, place several crumpled up balls of newspa per in the firebox. Place small dry pieces of kindling on top of the paper , criss-crossing the kindling so that there are air spaces in be- tween.
Use caution when firing with the combustion air control wide open. Only burn cord wood in this manner . Small dry pieces of softwood and construction sc raps wi ll burn very inte nsely using this method and may damage the firebox.
MAINT AINING YOUR BRENTWOOD™ L V FIREPLACE Cre osot e - F orm atio n and Nee d fo r Remo val When wood is burned slowly , it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow-burning fire.
REFRACTORY REPLACEMENT The intense heat of the fire will normally cause hairline cracks in the refractor y . These cracks can be minimized by proper curing as descri bed in “First Fires”. They will not normally dimin- ish the effectiveness of the refractor y .
GLASS CARE Glass Replacement The glass used for the Brentwood™ L V fireplace is a high temperature ceramic glass (1,400° F / 760° C). If the glass breaks, it must be replaced with an identical ceramic gl ass. T empered glass or ordinary glass will not withstand the high temperatures of the Brentwood L V fireplace.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 9 INST ALLING THE FINISHING KITS The Brentwood™ L V requires the installation of a finishing kit. T wo options are available: 1. Louver kit (part number: LOUVRECF) OR 2. Clean face kit (part number: CAPPINGCF) Installing The Louver Kit The louver kit includes two identical louver assemblies.
Framing, Facing And Mantel The construction of the framing, facing, and mantel must be in accordance with the stan- dards and the following illustrations ( Figures 9, 10 and 11 ): A.
Combustible materials can NOT be used in the space directly above the fireplace. Do not fill the space above the fireplace with any material (Except the wood framing) F 21 -1 /2 ” J 20-3/8” E 7’ Min.
Figure 13 Figure 12 Insulated Chase Construction Floor Ceiling Wall • Must have the same firestopping resistance as adjacent wall. • Must have the same insulation as adjacent ceiling. • Follow local rules regarding framing construction. 7’ (2.
Facing The facing installation method depends on your finishing kit choice. 1. Facing with the louver kit - The 2x3 framing must offset to the back by a distance equiva- lent to the thickness of your facing material so the surface of the facing be aligned with the fireplace face.
HOT AIR DUCTING INST ALLA TION Diff eren t hot ai r ducting sy stem s can b e i nsta lled with the Brentwood™ L V fireplace: - Gravity kit - Forced air kit Gravity Kit The gravity kit is designed for double hot air outlets and includes: (See Figures 20 and 21 ) - 2 telescopic lengths 8” I.
The duct system must be installed respecting the following: 1. Remove the plates closing up the 8” dia. holes on top of the fireplace. Then, cut the insulation and remove the plate under the insulation in order to obtain two 8” dia. openings. Fix the adaptors on the fireplace openings by turning clockwise ( Figure 20 ) .
Aluminum T ape Aluminum T ape Fireplace Connection Plastic Cover Insulation Flexible Pipe Fireplace OUTSIDE AIR CONNECTION TO THE FIREPLACE Figure 26 OUTSIDE AIR KIT - REQUIRED (Included w/fireplace) During operation, the fireplace requires fresh air for combustion and draws air out of the house.
6. The chimney must extend at least three (3) feet (915 mm) above its point of contact with the roof and at least two (2) feet (610 mm) higher than any wall, roof or building within ten (10) feet (3m) of it ( Figure 27 ) .
CHIMNEY INST ALLA TION INSTRUC- TIONS 1. Cut and frame the holes in the ceiling, floor and roof where the chimney will pass (see Figure 28 ). Use a plumb-bob to line up the center of the holes. The sizes are indicated in T able 2 for the floor and ceiling holes and T able 3 ( Page 19 ) for the roof holes.
Roof Down Slope Hole Size S LO P E A SH T / H T 6 1 03 + S -2 1 0 0 + / H T6 0 0 0 + A C R oo f P it c h 6 ” 6 ” 6 ” 0 * 1 2- 3 / 8 ” ( 3 1 4 m m ) 1 4- 1 / 8 ” ( 3 5 9 m m ) 1 5” ( 38 0 m.
Ch imn ey 6” Elbo w Offset & Height One Length Between Elbows T wo Lengths Between Elbows 8” 12” 18” 24” 36” 48” 8” & 48” 1 2” & 4 8” 1 8 ” & 48 ” 2 4” &.
ANGLED WALL RADIA TION SHIELD (RSM+ and RSMI30) When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled firestop or wall radiation shield must be installed.
CHIMNEY SUPPORT INST ALLA TION Universal Roof Support When installing a support, slightly lift the chimney system so the weight will lie on the support, not on the fireplace to reduce expansion noises. This support has three possible uses: 1. For ASHT / HT6103+ and S-2100+ / HT6000+, it must be used on a roof to support the chimney .
Follow these steps: 1- Position the fireplace in its location. T emporarily install the ASHT elbow on the top of the fireplace and, using a level, mark with an oval the location where the flue liner will enter the masonry chimney . 2- In the middle of the oval, drill a hole in the masonr y chimney at 30º.
Installation Accessories Description Cat./Part No. Finishing Kits (Required - Order Separately) Louver kit LOUVRECF OR Clean face kit CAPPINGCF Outside Air Kit (Required - included w/fireplace) Outsi.
CHIMNEY - P ARTS AND COMPONENTS LISTS Fireplace Model Brentwood L V - Approved Venting Components manu- factured by Security Chimneys International only . • 6” diameter chimney - AC (air cooled), Secure T emp™ ASHT (or Nova T emp™ HT6103+) and Secure T emp S-2100+ (or Nova T emp HT6000+).
(AC) Air -Cooled Chimney System* 6” I.D. and 11” O.D. Air Cooled, Stainl. Steel inner and zinc coated steel exterior AC Starter Adaptors One of the following adaptors is required if installing an .
CLEARANCE TO COMBUSTIBLES The following clearances meet the minimum requirements for a safe installation: Side wall: 24” (610 mm) measured from the fireplace side.
Brentwood™ L V Item # Description C at ./ Pa r t No . 1 Baffle refractor y (2 pieces) PR-ISO2205 2 Back refractor y PR-SR2996 3 Right side refractor y PR-SR2997D 4 Left side refractor y PR-SR2997G .
REPLACEMENT P ARTS - BRENTWOOD™ L V 1 8 15 16 17 20 10 14 12 11 13 20 22 23 24 21 25 26 30 31 19 2 3 4 5 6 7 P A I N T 18 28 29 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE.
Printed in Canada © 2011 Lennox Hearth Products P/N 506023-13 REV . A 02/2011 30 Y our Fireplace's Model Number ________________________________________ Y our Fireplace's Serial Number ____.
Een belangrijk punt na aankoop van elk apparaat Lennox Hearth LV (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lennox Hearth LV heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lennox Hearth LV vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lennox Hearth LV leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lennox Hearth LV krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lennox Hearth LV bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lennox Hearth LV kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lennox Hearth LV . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.