MODELS OTL Report No. 116-F-13-4 US Portland This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate.
2 LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS P ACKAGING The assembled vented gas fireplace heater is packaged with: • (1 set) Logs (packaged in a carton inside the firebox).
3 LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS W ARNING Improper installation, adjust- ment, alteration, service or maintenance can cause injur y or property damage. Refer to this manual.
4 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS T est gauge connections are provided on the front of the millivolt and electronic gas control valve (identified IN for the inlet and OUT for the manifold side).
5 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS HORIZONT AL VENT (Rear Vent.
6 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS 12 X Roof Pitch is X/12 2 FT MIN.
7 LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE.
8 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Models Combustible Shelf He.
9 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Figure 9: Minimum Mantel Cl.
Pressure Relief Plates 10 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Side Framing Unit Nailing Flange (No clearance to combustible framing is required .
11 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS G H Top View (Louvered Front Model Shown) Concentric Flue: Flue 4-1/2" (114 mm); Combustion Air 7-1/2" (190 mm).
12 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS FIREPLACE FRAMING SPECIFIC.
13 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Us e onl y ap pr ove d ve nt co mp on en ts (s ee Ap pr ove d V en t Co mpo ne nt s on Pa ge 2 ).
14 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Note: Convert inches into metric equivalent measurement, as follows: Millimeters (mm) = Inches x 25.
15 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Min. 10-1/2" (267 mm) Min. 10-1/2" (267 mm) First Vent Component Align the dimple (four places) with the opening of the locking incline channel on appliance collar .
16 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Framing Dimensions for Roof Pitch C D 0/12 10-1/2 in. 10-1/2 in. (267 mm) (267 mm) 6/12 10-1/2 in.
17 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Figure 31: Rear Vent - ONE.
18 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS T A BL E C H + H 1 Ma xim um H Ma xim um V Mi nim um fe et fe et fe et 5 (1 .
19 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Figure 35 The unitized design of the Secure Vent compo- nents will engage and seal both the inner and outer pipe elements with the same procedure.
20 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS IMPORT ANT : The vent termination is hot while in operation and for a period of time following the use of the fireplace.
21 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS H Max im um V Min imu m fe et fe et 5 (1 .52 4) 1 ( 0. 3 05 ) 10 ( 3.0 48 ) 2 (0 .
22 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS T ABL E H H + H 1 Ma xim um H Ma xi mu m V M ini mum fe et f ee t f ee t 5 (1 .
23 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Figure 44: T op Vent - THR.
24 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS 5" (127 mm) Radius Minimum Flexible Vent Section E.
25 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Step 5.
26 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Note: Remote receiver shou.
27 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS B. Br ush al l jo in t s a nd co n ne cti ons wi t h t he ga s le ak tes t so lu t io n to che ck f or le a ks .
28 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Step 9. INST ALL VOLCANIC STONE, GLOWING EMBERS AND LOGS NOTE: T urn off all electricity to the appliance before you install volcanic stone, embers and logs.
29 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS 1 Log Number Description (.
30 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Figure 58 MPD-3530 LOG PLA.
31 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Figure 59 MPD-4035 AND MPD.
32 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Step 10.
33 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS W ARNINGS • Air shutter adjustment should only be performed by a quali- fied profes sion al servic e tech- nician.
LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS 34 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 64 Combustible Finished Wall Materials Min. 1" (25 mm) This area must remain clear of combustible materials.
LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS 35 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE.
36 LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Listed Secure Vent™ Components Cat. No. Model Description 77L70 SV4.5L6 6 Inch (152 mm) 77L71 SV4.
37 LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Listed Secure Flex™ Components Cat. # Model Description H1969 SF4.5HT -2 Horizontal Square T ermina- tion for flex (without flex vent) 77L87 SFKIT12S Square T erm.
38 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Millivolt SIT Systems Propane Gas to Natural Gas Conversion Kits Models Catalog No.
39 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Burner Assembly Gas Valve Assembly Orifice Figure 67 Millivolt Appliances Step 4.
40 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Retaining Clip Ignitor Ass.
41 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS NOTES.
42 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Lennox Hearth Products res.
Een belangrijk punt na aankoop van elk apparaat Lennox Hearth MPDT-3328CPE-B (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lennox Hearth MPDT-3328CPE-B heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lennox Hearth MPDT-3328CPE-B vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lennox Hearth MPDT-3328CPE-B leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lennox Hearth MPDT-3328CPE-B krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lennox Hearth MPDT-3328CPE-B bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lennox Hearth MPDT-3328CPE-B kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lennox Hearth MPDT-3328CPE-B . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.