INSTALLATION AND OPERATION MANUAL FREESTANDING VENTED GAS FIRED ROOM HEATERS RETAIN THIS MANUAL FOR FUTURE REFERENC E P / N 775 , 029M Rev . B , 8 / 04 Model: L30 DVF-2 (Direct-Vent) This appl iance may be instal led in an aftermarket permanently located, manufactured (mobile) ho me, where not proh i b ited by local code s Report No.
IMPORTANT WARNINGS / CAUTIONS CAUTION: READ THIS MANUAL THOR OUGHLY BEFORE STARTI NG INSTALLATION. F OR YOUR SAFETY, FOL- LOW THE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS EXACTL Y WITHOUT DEVIATION. FAILURE TO FOLLOW THES E INSTRUCTIONS MAY RESULT IN A POSSIBLE FIRE HA ZARD AND MAY VOI D THE WARRANTY.
TABLE OF CONTENTS PAGE 3 Important Warn ings ........................................................ 2 Testing / Listing, Us ing this Manual ................................. 3 Planning Your In stallation .............................................
PLANNING YOUR INSTALLATION PAGE 4 LOCAL AND N ATIONAL CODE REQUIREMEN TS The installation of these appliances must conform with local codes or, in the abse nce of local codes, with the National Fuel Gas Code, (for USA) NFPA 54 / ANSI Z223.1-latest edition.
PLANNING YOUR INSTALLATION PAGE 5 QUESTIONS TO ASK THE LO CAL BUILDING OFFICIAL Correct installation is critical and imp erative for reducing f ire hazards and pe rilous conditions that ca n arise when gas appli- ances function improperly. The appliance must be installed per manufacturers’ instructions.
PLANNING YOUR INSTALLATION PAGE 6 CLEARANCES TO COMBUS TIBLE MATERIALS These appliances can be installed in most residential room configura- tions, parallel to a rear or adjacent wa ll, or in an alcove that allows for the minimum clearances to co mbusti ble surfaces.
INSTALLATION This appliance i s designed t o be vented wit h a 4” x 6 5/ 8” dir ect-vent pipe. Each direct-ve nt a ppliance must use its ow n separa te vent system PAGE 7 VERTICAL TERMINATION WITH NO OFFSETS Min. Vertical Pipe Length: 5 fe et Max.
INSTALLATION PAGE 8 VENT RESTRICTOR RING INSTALLA TION Recommended Restrictor Ring Placement For Optimum Stove Performance Guideline for Installing Flue Restrictor Ring in Co-Axial Direct-Vent Pipe If.
INSTALLATION See Pipe Manuf acturers Instruct ions For Inst allation O f Venting Com ponents & Cle arances. DIRECT VENT SYSTEM COMP ONENTS – Model L30 DVF-2 PAGE 9 The follow ing Direct- Vent system co mponents may be safely used w ith this appliance.
INSTALLATION PAGE 10 DIRECT VENT RETROFIT OF EXISTING CHIMNEY SYS TEM - An e xi s ti n g Class-A ( wo od - bu r ni n g) Metal Chimney or Masonry Chimney can be converted to a di rect vent system. Use one of the followi ng chimney conversion kits listed bel ow.
INSTALLATION PAGE 11 HORIZONTAL VENT TERMINATI ON REQUIREMENTS The venting terminals should not be reces sed into a wall or siding. A = 2” Clearances abov e grade, veranda, porch , deck or balcony. B = 12” Clearance to window or do or that may be opened.
INSTALLATION PAGE 12 GAS SUPPLY HOOKUP If using pipe other than black iron pi pe see NFPA 54-Nation al Fire Pro tec- tion Association / ANSI Z22 3.1-Amer ican Na tional Standards Institu te; and local code for spec ific requirements for th e type of pipe used.
INSTALLATION PAGE 13 DOOR OPERATION After setup of the logs and embers is complete, the glass door must be closed. T he glass door i s mounted on hinges at the left side of the fi rebox and is secured in the closed position by two draw latche s mounted on the right side of the firebox.
INSTALLATION PAGE 14 GAS APPLIANCE FINAL ASSEMBLY After the appliance has been prop erly installed and all gas connection s have been made an d tested, you can now inst all the log set.
INSTALLATION PAGE 15 INSTALLATION CHECK LIST Read and understan d these instructions befo re using appliance. Go through this installation checkli st: Ensure that the log set is properly i nstalled. Use cau- tion when handling the logs. See page 12.
CARE AND OPERATION PAGE 16 FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or ex plosion may result cau sing property damage, pers onal injury or loss of life. A . This appliance has a pilot which m ust be lit.
CARE AND OPERATION PAGE 17 “BREAK-IN” PERIOD The finish on this appliance is a hi gh temperature paint that requires time and temperature to completely cure. The curing process will take 2 or 3 burns (heat up and cool down peri- ods). We recommend that you ventilate the house duri ng the initial burns.
PROPANE CONVERSION PAGE 18 PROPAN E CONVERS ION PROC EDURE (Only require d if Propane gas is used) This appliance is desig ned to operate on natural gas, or pr opane (LP). It is factory set for use with natural gas and re quires field conversion f or use with propa ne.
PROPANE CONVERSION PAGE 19 7. High / Low Pressure Regula tor Installation Procedure: a. Remove regulator cap and conversion screw (see fol- lowing illustration). b. Install the new conversion screw (Red = Propane LP gas, Blue = Natural Gas ). Ensure that the conversion screw is finger tight.
MAINTENANCE Always Turn Off Gas Control Valve Before Cleaning. Annual Maintenance Should Only Be Performed By A Qualified Service Technician: PAGE 20 LOG SET Removing & Cleaning Logs - Carefully remove the logs (re mov- ing top logs, then liftin g front log out, then rear log).
MAINTENANCE Always Turn Off Gas Control Valve Before Cleaning. Annual Maintenance Should Only Be Performed By A Qualified Service Technician: PAGE 21 PERIODIC CHECK OF PILO T AND BURNER FLAM ES Check the operation of the pilot and cycle the burner. Visually check the flame of the burner making su re the flames are steady; not lifting or floating.
WIRING DIAGRAMS PAGE 22 GAS CONTROL AND SAFETY SYSTEM WIRI NG DIAGRAM CAUTION: Lab el all wiring prior t o disconnection w hen servicing controls. Wiring errors can ca use improper an d dangerous oper a- tion.
TROUBLESHOOTING Qualified Technicians Only PAGE 23 PROBLEM CAUSE(S) SOLUTIONS 1) Pilot will not light, and Piezo Igniter does not produce a heavy blue spark. a. Electrode wire (at Piezo Igniter) not pushed completely on. b. Piezo igniter is defective • Make sure connections are solid.
REPLACEMENT PARTS Model: L30 DVF- 2 PAGE 24 I t e m # Des cription Cat. No. 1 Trim, Decorative 10050164 2 Window Frame, Charcoal 17M60 3 Burner Assembly 17M58 4 Blower, Air Circulating 52L02 5 Thermal Fan Switch 52L12 6 Power Cord (blower) 12058820 7 Rheostat w / Knob (speed contro l for blower) 10050088 I t e m # Des cription Cat.
OPTIONAL ACCESSORIES PAGE 25 Item # Description Catalog # Model 1 Door Kit, L30 DVF-2, Gold 14M08 DK3D-G 2 Brickaded Interior Kit, L30 14M06 BRK-L30 3 Deluxe Remote Control (Thermost atical ly control.
SPECIFICATIONS: Model L30 DVF-2 PAGE 26 Flue Size 4” – Top Vent Intake Pipe 6.625” (6 5/8”) Height Overall 30 5/8” Height 29 1/8” Width 30 1/8” Depth 16 1/8” Fuel Natural Gas (standard) (or) LP Gas (convertible). Gas inlet 3/8” NPT-Male/Flex Line (or) remove flex, 3/8” NPT–Female Flare.
SAFETY / LISTING LABEL (RATING PLATE) If the rating plate on the unit is d ifferent than sho wn here, the rating plate on the unit is th e correct one.
PAGE 28 OWNERSHIP RECORDS Dealer’s Nam e: Dealer’s Address: City: State: Zip Code: Serial Number: Date of Pu rchase: Date Installed: Notes: SERVICE AND MAINTENANCE LOG Service Service Service Date.
Printed in U.S.A LENNOX HEARTH PRODUCTS 2001 P/N 775,029M REV. B 08/2004 1110 West Taft Avenue • Or ange, CA 92865 LENNOX reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also for di scontinued colors, styles and products.
Een belangrijk punt na aankoop van elk apparaat Lennox Hearth Products L30 DVF-2 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lennox Hearth Products L30 DVF-2 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lennox Hearth Products L30 DVF-2 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lennox Hearth Products L30 DVF-2 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lennox Hearth Products L30 DVF-2 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lennox Hearth Products L30 DVF-2 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lennox Hearth Products L30 DVF-2 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lennox Hearth Products L30 DVF-2 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.