Gebruiksaanwijzing /service van het product Winslow PI40 van de fabrikant Lennox Hearth Products
Ga naar pagina of 36
INST ALLA TION AND OPERA TION MANUAL Save These Instructions For Future Reference Pe ll et I ns er t Mo de l W in sl ow ™ (P I4 0) Pe ll et -F ir ed Fi re pl ac e In se rt P/N 775 ,229 M, R ev . C, 1 1/200 8 US Portland A Fr ench man ual is a vail able upo n re ques t.
2 1. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. 2. Do not connect this appliance to air ducts or any air distribu- tion system.
3 CONGRA TULA TIONS! When you purchased your new pellet stove, you joined the ranks of thousands of individuals whose answer to their home heating needs, aesthetics, efficiency and our environment. We extend our continued support to help you achieve the maximum benefit and enjoyment avail- able from your new pellet stove.
4 PLANNING YOUR INST ALLA TION W ARNING Che ck a ll lo cal buil din g and safe ty c ode s bef ore ins tal lat ion . The ins tal lat ion ins tru cti ons and app ro- pri ate co de r equ ire men ts mus t be fol low ed exa ctl y an d with out comp rom ise .
FEA TURES AND SPECIFICA TIONS Wood pellets manufactured to the pellet fuels institute (P .F .I.) certification standard are available in two grades, Standard and Premium. The primar y difference between the two is the ash content of the pellets. The P .
6 Front View Figures 3 and 5 shows the minimum sized fireplace required for the Winslow™ PI40 insert when any of the four non-extended surround sizes are used. With the hopper at its largest size (as shipped from the factory), the fireplace needs to be a minimum of 22-1/2” (572 mm) high.
7 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Mantel Floor Protection Combustible W a ll 6” (15 2mm) 9-1 /2” (24 1mm ) 7-1 /2” (19 1mm ) 10” (25 4mm ) Max .
8 Control Board Installation The Winslow PI40 insert is shipped with the control board wrapped and placed behind the firebox. T o install the control board, unwrap it and the right side surround panel found in the surround kit. There are four prongs protruding from the surround.
9 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. A = Clearance above grade, veranda, por ch, deck, or balcony (min. 12”/30cm) B = Clearance to window or door that may be opened (min. 12”/30cm above - 48”/1.2m below and to the side) C = Clearance to permanently closed window *(min.
10 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. *The block off panel should be air tight to ensure smoke does not enter the house and to help establish chimney draft when the pipe does not terminate at the top of the chimney .
11 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Cap Flashing Outside Air Pipe Listed Pellet Pipe or Flex Liner Storm Collar Figure 12 CON TROL BOAR D 36" FIREPLACE OPENING 18" 13-1/.
12 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Wir ing Bloc k B A Rear View of Control Board Door T rim Installation Instructions Parts List (A) Qty (2) T rim Pieces (Gold, Nickel, Brushed N.
13 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. T rim stud Door Handle Holes for trim studs T rim Nuts #10 washers T rim Pieces T op of T rim A Figure 15 Figure 16 Figure 17 Figure 18 4. Place one washer on each stud. Using a 3/8” nut driver , snug up the nuts on each piece of trim.
14 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Door Grill Installation Instructions Parts Needed Qty (4) Button Head Screws (already in place in insert) T ools Required: 1/8” allen wrench T o install the Grill: 1. Remove the four button head screws from body of the insert with a 1/8” allen wrench.
15 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Note: The brick panel comes pre-painted with Metallic Black paint. The brick panel may be painted with any color of high-temp paint (paint may discolor with use). 1. Remove the front door of the pellet insert.
16 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 5. Screw in the four tap tights, included with this kit, using a 5/32 allen wrench. 6. Replace the burn pot and check that it is firmly in place (if you can rotate the burn pot it is not installed correctly).
17 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Log Set Installation Instructions Kit Contents (refer to Figure 30) Cat. No. #H5142 Qty (1) left log (B) (1) right log (C) (1) front log (D) (2.
18 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Control Board The control board regulates all functions of the insert. The following is a list of the board’ s components: • Feeding light - lights up when the auger is feeding pellets into the burn pot.
19 Shut Down Normal - T o turn the insert off, turn the heat selector knob to off. The fans will continue to operate until the control board completes the shut down cycle. Power Outage - If the insert loses electrical power for less than 10 seconds it will continue to operate.
20 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. IMPORT ANT CAUTIONS: • UNPLUG POWER CORD AND ENSURE APPLIANCE IS COLD BEFORE PERFORMING ANY MAINTENANCE WORK.
21 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 36A B C Cleaning the Combustion Blower T o clean the combustion blower , unplug the insert from the power source and remove the six nuts labeled A in Figure 37 with an 11/32” wrench. After removing these nuts, the motor with fan attached can be pulled from the fan housing.
22 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. A Blower Duct Removing the Ash from the Firebox CAUTION: Do not remove the ash when the insert or ash is hot. T o remove the ash, swing open the left and right side doors and open the front door .
23 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Front Door Opening and Removal CAUTION: Do not open the front door when the insert is hot. T o remove the door , swing the left and right side doors A open. Pull the front door handle B to the front and swing the front door open.
24 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. The following is a list of components and their functions. Igniter The Winslow™ PI40 insert comes equipped with an automatic igniter for lighting the fuel when the insert is in the lighting mode.
25 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. A Draft Adjuster Draft Adjuster The Winslow™ PI40 insert has a draft adjuster located at the right side of the insert directly in front of the combustion blower .
26 If the insert operates abnormally , the ready light on the control board will signal the nature of the abnormal operation. The following is a list of pos- sible signals or codes: Ready light is con.
27 Orange Sooty Flames - Glass turns Black Possible Problem Solution Burn pot is dirty Clean the burn pot Vent pipe restricted Clean the vent pipe Flue gas passageways restricted Clean the passageways.
Surround Panel Kits (required - sold separately) Cat. No. Model Description 79004 PI40-FPK2941 29” Ht. x 41” Wd. Black T rim 79005 PI40-FPK2948 29” Ht. x 48” Wd. Black T rim 79006 PI40-FPK3341 33” Ht. x 41” Wd. Black T rim 79007 PI40-FPK3348 33” Ht.
29 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Heat Kit Instructions Kit Contents (Refer to Figure 47) 1 ea. 2” lower trim piece (A) 1 ea. 1” insulated micro board (B) 2 ea. 1/2” x 10-24” screws (C) T ools Required 5/32 allen wrench 1.
30 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Pellet Insert ZC Kit Assembly Kit Contents (refer to Figure 52) 1 ea. Back panel (A) 1 ea. Left side panel (B) 1 ea. Right side panel (C) 1 ea. T op panel (D) 1 ea. Access panel (E) 1 ea. Flue block off plate (F) 6 ea.
31 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 4. Installing the standoffs, parts G. There are 3 standoffs on the top panel D (see Figure 57 ) . Insert them by taking the lip of the standoff and sliding them into the slots then push down. Using a sheet metal screw provided screw them into the hole provided.
32 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 6. Installing access panel: T aking the access panel (E in Figure 61 ) and 4 of the sheet metal screws provided, screw the access panel E onto the right side panel C as shown in Figure 61 ) . 7.
33 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. ZC Framing Dimensions for Combustible /Floor 10-3/8” 19-1/2” 25-1/2” 29-1/2” 16-1/8” 6-3/4” 4” 3-1/2” 8-1/4” 9-1/8” 39” E.
39” 9-1/8” 8-1/4” 28” 16-1/8” 10-3/8” 19-1/2” 25-1/2” 4-3/4” 3” 2-1/2” ZC Framing Dimensions for Non-Combustible Hearth /Floor Exhaust T op View Front 39” 9-1/8” 8-1/4” 28.
35 NOTES.
36 Y our Insert’ s Model Number __________________________________________ Y our Insert’ s Serial Number ___________________________________________ The Date On Which Y our Insert Was Installed __.
Een belangrijk punt na aankoop van elk apparaat Lennox Hearth Products Winslow PI40 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lennox Hearth Products Winslow PI40 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lennox Hearth Products Winslow PI40 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lennox Hearth Products Winslow PI40 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lennox Hearth Products Winslow PI40 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lennox Hearth Products Winslow PI40 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lennox Hearth Products Winslow PI40 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lennox Hearth Products Winslow PI40 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.