Gebruiksaanwijzing /service van het product SYM-45N van de fabrikant Lennox Hearth
Ga naar pagina of 28
INST ALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. INST ALLA TEUR : Laissez cette notice avec l'appareil. CONSOMMA TEUR : Conservez cette notice pour consultation ultérieure. MODELS DON’T THROW IT AW AY ! This manual contains important operating and safety information.
2 S a f e t y an d Y our Fireplace T o prevent severe burns and injuries, install a screen or physical barrier to prevent direct contact with the glass.
3 Afin d'éviter de vous brûler gravement ou de vous blesser , installez une grille ou une barrière physique pour empêcher tout contact direct avec la vitre. Pour commander un P ANNEAU DE PROTECTION Lennox ® GRA TUIT pour votre foyer , consultez les détails dans la partie gauche.
4 Important Safety Information WARNING: Do not operate appliance with the glass front 1. removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person . Do not use this appliance if any part has been under water .
5 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. HOMEOWNER’S INSTRUCTIONS - A TT ACHING SAFETY -IN-OPERA TION WARNINGS A TT ACH IN G SAF ETY -IN -O PE RA TIO N WARNINGS Y our fireplace has been furnished with safety instruc - tion labels that are to be affixed to the operation and co ntr o l p oin ts of t he fi rep la ce.
6 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. General Information The fireplace models covered in this manual are direct-vent sealed combustion gas fireplace heaters designed for residential application. These direct-vent appliances operate with the combustion chamber completely isolated from the indoor environment.
7 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Orifice Sizes - Sea Level to High Altitude (All Models): Thes e appli anc es are teste d .
8 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Gas Controls/Control Compartment Access The gas control valve can be found behind the control compartment access door ( Figure 2 ). Removing Control Compartment Door: The control compartment door sits in place below the front glass enclosure panel.
9 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 5 Figure 4 Indicator Icons Flame Level 5 T ransmission Thermostat Off/On/Smart Set Point T emp.
10 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. T o activate this function, press the Thermostat Key until the word "SMART" appears to the right of the temperature bulb graphic.
11 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. MAINTENANCE (See Maintenance Schedule, Page 24) Refer to the maintenance schedule for maintenance tasks, procedures, periodicity and by whom they should be performed. Always verify proper opera - tion of the appliance after servicing.
12 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 8 6. Let the bottom of the door frame swing gently in towards the fireplace ensuring that the gasket seats evenly as the door frame draws shut. Fasten the two latches located underneath the firebox floor to the door's vee-flange.
13 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. W ARNING • DO NOT attempt to install the logs until the appliance installation has been completed, the gas line connected and tested for leaks and the initial burner operation has been checked out.
14 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SYM-35 LOG PLACEMENT Figure 11 Log Number Description 1 Rear Log 2 Bottom Left Log 3 Bottom Right Log 4 T op Right Log 5 Front Log (3) Catalog .
15 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SYM-40 LOG PLACEMENT Figure 12 Log Number Description 1 Rear Log 2 Bottom Left Log 3 Bottom Right Log 4 T op Left Log 5 T op Right Log 6 T op R.
16 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SYM-45 LOG PLACEMENT Figure 13 Log Number Description 1 Rear Log 2 Bottom Left Log 3 Bottom Right Log 4 T op Left Log 5 T op Left Cross Log 6 T.
17 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. BURNER ADJUSTMENTS (QUALIFIED TECHNICIANS ONL Y) Flame Appearance and sooting Proper flame appearance is a flame which is blue at the base and becomes yellowish-orange in the body of the flame.
18 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. W ARNINGS • Air shutter adjustment should only be performed by a quali- fied professional service technician. • Ensure front glass panel are in place and sealed during adjustment. CAUTIONS • Carbon will be produced if the air shutter is closed too much.
19 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. WIRING DIAGRAM The wiring diagram is provided here for reference purposes only . This information is also prov ided on sch ematics attache d directl y to the appliance on a pullout panel located within the control compartment.
20 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. ACCESSORY COMPONENTS Product Reference Information Cat. No. Model Ship. Weight Ship. Volumn H6951 SYM-35N 165 lb. 26.1 cu. ft. H6952 SYM-35P 165 lb. 26.1 cu. ft. H6954 SYM-40N 188 lb. 29.6 cu. ft.
21 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. ACCESSORY COMPONENTS CONTINUED Style View Doors - Style View Doors come in 2 beautiful styles. They are easy to install and will not require hardware to attach them to the standard glass door frame.
22 A. When lighting the appliance, follow these instructions exactly . B. BEFORE OPERA TING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor . WHA T TO DO IF YOU SMELL GAS • Extinguish any open flame.
23 INSTRUCTIONS D’ALLUMAGE INSTRUCTIONS D’ALLUMAGE POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMA GE A. Lorsque vous allumez l’appareil, suivez exactement ces instruc- tions.
24 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Periodically (After the Burning Season) Maintenance T ask Accomplishing Person Procedure Cleaning Firebox Interior Check Flame Patterns and Fla.
25 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. TROUBLESHOOTING THE SYMMETR Y FIREPLACE SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION Check that the wall switch plate is set to remote (if remote was used). Operate the fireplace from the wall plate switch.
26 REPLACEMENT P ARTS LIST W ARNING Fa il u r e to po si ti on th e pa rt s in ac co rda nc e wi th th es e diagrams or failure to use only parts specifically ap pr o v ed w it h th is ap pl ia n ce m ay r es ul t in pr o pe rt y damage or personal injury .
27 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. REPLACEMENT P ARTS 47 44 5 10 42 46 4 6 40 43 45 17 1 3 15 16 18 8 41 48 2 7 14 13 11 12 9 49 50 51 52 19.
Printed in U.S.A. © 2009 Lennox Hearth Products P/N 506025-01 REV . C 01/2011 Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.
Een belangrijk punt na aankoop van elk apparaat Lennox Hearth SYM-45N (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lennox Hearth SYM-45N heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lennox Hearth SYM-45N vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lennox Hearth SYM-45N leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lennox Hearth SYM-45N krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lennox Hearth SYM-45N bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lennox Hearth SYM-45N kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lennox Hearth SYM-45N . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.