1100AdvSvc REV 1/5/07 SER VICE MA NUAL (DOMESTIC ) IMPING ER CONVEYOR O VENS IMPINGER II - ADV ANT AGE SERIES Lincoln Foo dservice Products, LLC 1111 North Hadley Road Fort W ayne, Indiana 46804 United States of America Phone : (800) 374 -3004 U.
Impinger II – Advantage Service Man ual - Dom estic 2 T A BLE OF CONTENTS TABLE OF CO NTENT S 2 SEQUENC E OF OPER ATIONS 4 SEQUENC E OF OPER ATIONS 5 SCHEMAT IC 1116-000-A , 1117-000- A 6 SCHEMAT IC.
Impinger II – Advantage S ervice Man ual - Dom estic 3 SEQUENCE OF OPERA TIONS IMPING ER II ADV A NT A GE MODEL 11 16-000-A / NAT URAL GAS / 1 20 VAC / 6 0 HZ / 1 PHA SE MODEL 11 17-000-A / L. P. GAS / 120 V AC / 60 HZ / 1 PHASE POW ER SUPPLY Electrical po wer is suppli ed to the ove n by a three c onductor cords et.
Impinger II – Advantage Service Man ual - Dom estic 4 SEQUENCE OF OPERA TIONS 1130-000- A / 208V / SINGL E PHASE 1131-000- A / 240V / SINGL E PHASE 1132-000- A / 208V / TH REE PHASE 1133-000- A / 24.
Impinger II – Advantage S ervice Man ual - Dom estic 5 SCHEMA TIC 1 1 16-000-A , 1 1 17 -000-A.
Impinger II – Advantage Service Man ual - Dom estic 6 SCHEMA TIC 1 130-000-A / 1 131- 000-A.
Impinger II – Advantage S ervice Man ual - Dom estic 7 SCHEMA TIC 1 132-000-A / 1 133- 000-A.
Impinger II – Advantage Service Man ual - Dom estic 8 TROUBLESHOOTING GUIDE / GA S OVENS MODEL 11 16-000-A NATURAL G AS 120 VAC 60 HZ 1 PHASE MODEL 11 17-000-A LP GAS 120 VAC 60 HZ 1 PHASE SYMPTO M POSSIBLE CAUSE EVALUAT ION Oven fan wi ll not run Inc oming Power S uppl y Check breakers, r eset it required.
Impinger II – Advantage S ervice Man ual - Dom estic 9 Burner Blo wer Motor Visuall y check to see if m otor is running. If not, check for 120 VAC to m otor at m otor connector ( wire #5 and #22). If voltage is n ot present, trac e wiring back to f an switch.
Impinger II – Advantage Service Man ual - Dom estic 10 Power Supp ly If there is suf ficient m icro-am p current, but the f lame will not sta y lit, check for proper polar ity of the 120 VAC power s uppl y .
Impinger II – Advantage S ervice Man ual - Dom estic 11 Speed Adjus tment Potentiom eter This is a 0 to 10 K ohm , 1 turn potentiom eter. W ith power off , remove the blac k and white po t leads from the motor control boar d at term inals P1, P2. Place the m eter leads on t he black lead (P2) an d on the white lead ( P1).
Impinger II – Advantage Service Man ual - Dom estic 12 Tem p. display inoperat ive Display Tr ansformer Measure the transform er prim ary for a nominal 12 0 VAC input, if voltage is not present, tr ace wiring bac k to the oven power source. Measure the sec ondar y output, which will norm ally be 12-15 VA C.
Impinger II – Advantage S ervice Man ual - Dom estic 13 TROUBLESHOOTING GUIDE / ELEC TRIC OVENS MODEL 11 30-000-A 208 VAC SINGLE PHA SE 60 HZ MODEL 11 31-000-A 240 VAC SINGLE PHA SE 60 HZ MODEL 11 3.
Impinger II – Advantage Service Man ual - Dom estic 14 Tem perature Control Check for supply voltage at temper ature control. If no voltage is pr esent, trac e wiring b ack to hi-lim it therm ostat. Turn the tem perature adjus tment k nob to max imum temper ature position and c heck for 208/240 V AC at the load t erminals 7 and 8.
Impinger II – Advantage S ervice Man ual - Dom estic 15 Speed Adjus tment Potentiom eter This is a 0 to 10 K ohm , 1 turn potentiom eter. W ith power off , remove the blac k and white po t leads from the motor control boar d at term inals P1, P2. Place the m eter leads on t he black lead (P2) an d on the white lead (P1).
Impinger II – Advantage Service Man ual - Dom estic 16 Hall Effec t Sensor Check for any physical da mage to hall effect s ensor (mounted on c onveyor dr ive m otor.) Check all wiring and con nections f or damage. chec k all connections f or dam age.
Impinger II – Advantage S ervice Man ual - Dom estic 17 REMOV A L, INST A LLA TION, A ND A DJUSTMENT IMPING ER II ADV A NT A GE CAUTION ! BEFORE R EMOVING OR I NSTALLING ANY COM PONENT IN THE IMPINGER OVEN, B E SURE T O DISCON NECT ELECTR ICAL POW ER AND GAS SU PPLY.
Impinger II – Advantage Service Man ual - Dom estic 18 FUSE HOL DER - REPL ACEMENT 1. Shut off power at m ain break er. 2. Remove contro l box cover and f ront panel. 3. Remove wires f rom fuse holder a nd mark for reass embly. 4. Remove m ounting screws or mounting nut on fuse hol der.
Impinger II – Advantage S ervice Man ual - Dom estic 19 BURNER T RANSFORM ER - REPL ACEMENT 1. Shut power off at main break er. 2. Remove contro l panel top and f ront cover. 3. Remove two (2) wires on pr imar y side, note co lor and loc ation. 4. Remove two (2) wires on secondar y side, note color a nd location.
Impinger II – Advantage Service Man ual - Dom estic 20 ELECTRO NIC TEM PERA T URE CONTRO L BOARD - REPLACEM ENT 1. Remove contro l box cover. 2. Disconnect wires a nd mold ed connector a nd mark for reinstallation. 3. Depress n yl on clips and rem ove circuit board f rom m ounting brack et.
Impinger II – Advantage S ervice Man ual - Dom estic 21 BYP ASS ORIFICE 1. Shut off power at m ain break er. 2. Shut off gas s upply to oven. 3. Remove contro l panel top and f ront cover. 4. Remove pilot tub e from bypass orifice and remove orifi ce.
Impinger II – Advantage Service Man ual - Dom estic 22 CONVEYOR CO NTROL BOARD - REPL ACEM ENT 1. Shut off power at m ain break er. 2. Remove contro l panel top and f ront cover.
Impinger II – Advantage S ervice Man ual - Dom estic 23 HALL EFFE CT SENSOR - REPL A CEM ENT 1. Shut off power at m ain break er. 2. Remove contro l panel top and f ront cover. 3. Remove conve yor motor as sembly. 4. Remove wire co nnector fr om hall eff ect sensor board.
Impinger II – Advantage Service Man ual - Dom estic 24 HEATING ELEMENT - REPLACEMENT 1. Shut off power at m ain break er. 2. Remove back cover. 3. Disconnect heater element wires and m ark for reas sembl y . 4. Disconnect m otor wiring and m ark for reassembl y .
Impinger II – Advantage S ervice Man ual - Dom estic 25 This page in tentionally left blank..
Impinger II – Advantage Service Man ual - Dom estic 26 P A RTS / GENERAL LETTER PART NUM BER DESCRIPT ION A 369390 Caster 4” w/ Mounting Pl ate B 369502 Bottom Finger Cover C Colum nating Panel, s.
Impinger II – Advantage S ervice Man ual - Dom estic 27 BLOW UP / GENERAL.
Impinger II – Advantage Service Man ual - Dom estic 28 P A RTS / CONTROL BOX 1 1 16-000-A , 1 1 1 7-000-A LETTER PART NUM BER DESCRIPT ION A 370108 Control Box Top B 369128 Pilot Light C 370073 Temp.
Impinger II – Advantage S ervice Man ual - Dom estic 29 BLOW UP / CONTROL BOX – 1 1 16-000-A , 1 1 17-000- A.
Impinger II – Advantage Service Man ual - Dom estic 30 P A RTS / CONTROL BOX – 1 130-000-A THRU 1 133-000-A LETTER PART NUM BER DESCRIPT ION A 370108 Control Box Top B 369467 Pilot Light C 370073 .
Impinger II – Advantage S ervice Man ual - Dom estic 31 BLOW UP / CONTROL BOX – 1 130-000-A THRU 1 133-000-A.
Impinger II – Advantage Service Man ual - Dom estic 32 P A RTS / CONVEYOR & DOOR LETTER PART NUM BER DESCRIPT ION A 369611 Coupler B 369664 Coupling C enter C 369269 Bal l Plunger D 370116 Set S.
Impinger II – Advantage S ervice Man ual - Dom estic 33 BLOW UP / CONVEYOR & DOOR.
Impinger II – Advantage Service Man ual - Dom estic 34 P A RTS / OVEN BACK A SSEMBL Y LETTER PART NUM BER DESCRIPT ION A 369182 Fan B 369899 Fan Shroud C 3696 55 Stand Off D 3691 83 Heating Elem ent.
Impinger II – Advantage S ervice Man ual - Dom estic 35 BLOW UP / OVEN BACK A SSEMBL Y.
Impinger II – Advantage Service Man ual - Dom estic 36.
Een belangrijk punt na aankoop van elk apparaat Lincoln 1117-000-A (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lincoln 1117-000-A heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lincoln 1117-000-A vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lincoln 1117-000-A leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lincoln 1117-000-A krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lincoln 1117-000-A bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lincoln 1117-000-A kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lincoln 1117-000-A . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.