1600expad v REV: 1/8/07 SER VICE MANU AL (INTERN ATION AL) IMPING ER CONVEYOR OVENS LOW PROFILE 1600 INTERNATIONAL ADVANTAGE Lincoln Foo dservice Products, LLC 1111 North Hadley Road Fort W ayne, Indiana 46804 United States of America Phone: (800 ) 374-3004 U.
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 2 SERVICE AND PARTS MANUAL 1600 INTERNAT IONAL ADVANTA GE SEQUENC E OF OP ERAT IONS ....................................................................... ..................
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 3 SEQUENC E OF OP ERATIO NS MODEL 16 33-000-E A 230 VA C 50HZ N ATUR AL GAS MODEL 16 34-000-E A 230 VA C 50HZ L.P. GA S POW ER SUPPLY Electrical po wer to b e supplied to the ove n b y a three conduct or service .
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 4 Adjustm ents of the s peed control potentiom eter will change r esistance at term inals P1 a nd P2 var ying the D C voltage to the m otor.
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 5 SCHEMATIC MODELS 1633-000-EA AND 1634-000-E A.
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 6 TROUBLESHOOTING GUIDE MO DEL 16 33-000 EA NATURAL GAS 23 0 VAC 50 HZ 1 PH ASE MO DEL 16 34-000-E A L.P. GAS 230 V AC 50 HZ 1 PHASE NOTE: When che cking components on l eft side of unit, be sure to chec k for proper connections in power connector, ( marked P.
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 7 Fuse holder Check , replace if nec essary. Gas press ure switch Check for supply voltage to neutral (internal to g as val ve) on both sides of switch. If v oltage is present on o ne side of switch onl y, check the following.
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 8 replace the s park generator. If there is visible dam age to t he igniter/s ensor assembl y, replace. Also chec k for fr ayed or dam aged wires in burner tube . Gas valve Check f or supply voltage to gas val ve.
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 9 as needed. Tem perature regulat ion If supply volt age is prese nt on th e valve tem perature c ontrol boar d at the l oad term inals #7 and #8, ch eck for voltage at temper ature regulati on val ve.
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 10 gear m otor and the m otor does not r un, f irst check the mini bre aker and th en the con ve yor. Refer to the next poss ible caus e. Check the leads to t he m otor for evidenc e of any shorts or opens , and eac h lead to ground.
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 11 secondar y readings ar e not ac hieved, replace trans form er. Tem perature displa y If proper volt age is pres ent at ter m inals 1,2, and 3 o n tem perature displ ay, but but the displ ay is not l ighted, rec heck all connectio ns for tightness .
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 12 REMOVAL, INSTALLA TION & AD JUSTMENTS MODEL SE RIES 1633-000-EA , 1634-000-EA CAUTION ! BEFORE R EMOVING OR INST ALLING ANY COM PONENT IN T HE IMPINGER O VEN B E SURE T O DISCON NECT ELECT RICAL POW ER AND GA S SUPPL Y.
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 13 CONVEYOR CO NT ROL BOARD – CALIBR ATIO N A. Connect digit al volt m eter t o the hall ef fec t sensor. Black meter lead co nnected t o black hall effec t sensor lead, re d m eter lead to white hall affec t sensor lead.
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 14 F. Disconnect pipe uni on just abo ve gas v alve and r em ove assem bly. G. Reassem ble in rever se order (check all pipe fitt ings for leak s ). After assem bled check for proper adjus tm ent of gas pres sure switch, 1 0 on d ial for natura l gas, 27 f or L.
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 15 E. Rem ove assem bly and repl ace m ain orifice. F. Reassem ble in rev erse ord er and chec k s ystem opera tion. NOT E: Check all gas line fittings f or leak s. TEMPERAT URE CONT ROL POT ENT IOMET ER – REPL ACEMENT A.
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 16 CAPACITO R, MAIN F AN MO TOR – REPLACEMEN T A. Rem ove appropriate co ntro l box cover. B. Rem ove 2 wires fr om capac itor, note wire n um ber and locat ion. C. W ARNING: Capacitor has a s tored charge, dischar ge bef ore hand ling or testin g.
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 17 H. ( note location of fan blade for reinstal lation ) I. Loosen lock nuts on co ne. Rem ove 2 m ounting bolts and rem ove m otor f rom J. back assem bly. K. Rem ove 4 hex head s crew s from motor mount br ack et.
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 18 The f ollowing chart l ists the therm oc ouple millivolt readings f rom 200 ° F to 600 ° F. O V E N T E M P 200° F 250° F 300° F 325° F 350° F 400° F 425° F 450° F 500° F 550° F 600° F J 90° F 3.
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 19 This page in tentionally left blank..
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 20 GENERAL PART S ADVANTAGE SERIES LETT ER PART # DESCRIPT ION A 369110 Acces s windo w assem bly B 369929 W indow retainer.
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 21.
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 22 CONTROL BOX, RIGHT PA RTS 1633-000-EA, 1634-000-EA LETT ER PART# DESCRIPTION A 3691 58 Sprocket, 10 t ooth B 3697 05 Therm ocouple C 369757 Main orifice, Nat. 369758 Main orific e, L.
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 23.
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 24 CONTROL BOX, LEFT PA RTS 1633-000-EA, 1634-000-EA LETT ER PART# DESCRIPTION A 3697 06 Therm ocouple with ex tension B 36.
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 25.
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 26 OVEN BACK PARTS 1633-000-EA , 1634-000-EA LETT ER PART# DESCRIPTION A 3695 47 W ire form thermos tat bulb B 3697 24 Fan, clock wise rotatio n C 369776 Fan shroud D 369777 Stand-off E 3697 78 Rear wall as sy.
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 27.
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 28 CONVEYOR PARTS 1633-000-EA , 1634-000-EA LETT ER PART# DESCRIPTION 369830 Com plete conve yor A 3698 16 Conve yor belting B 3698 25 Belt, 1ft.
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 29.
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 30 This page in tentionally left blank..
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 31 This page in tentionally left blank..
Low Prof ile – 1600 Ad vantage S eries Ser vice Man ual – Intern ational 32.
Een belangrijk punt na aankoop van elk apparaat Lincoln 1633-000-EA (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lincoln 1633-000-EA heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lincoln 1633-000-EA vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lincoln 1633-000-EA leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lincoln 1633-000-EA krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lincoln 1633-000-EA bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lincoln 1633-000-EA kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lincoln 1633-000-EA . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.