CLA SSIC ® 300G OPERA TOR’S MANUAL For Machines with Code Numbers 10659,10912,11135 IM659-B December, 2004 Safety Depends on You Lincoln arc welding equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation .
FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.
iv SAFETY iv Mar. ‘93 PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1.
v v Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
vi vi T ABLE OF CONTENTS Page Installation .......................................................................................................Section A Technical Specifications ......................................................................
TECHNICAL SPECIFICA TIONS – CLASSIC 300G (K1754-1) CLASSIC 300G A-1 INST ALLA TION A-1 DC CURRENT RANGE Fine Adjustment in each Range 40-350 Amps DUTY CYCLE 100% 60% RATED DC OUTPUT* VOLTS @ RATED AMPS 30V @ 250A NEMA Rating 32V @ 300A (1) 115V will operate either 60 Hz.
PRE-OPERA TION INST ALLA TION EXHAUST SP ARK ARRESTER Some federal, state or local laws may require that engines be equipped with exhaust spark arresters when they are operated in certain locations where unarrested sparks may present a fire hazard. The standard muffler included with this welder does not qualify as a spark arrester.
PRE-OPERA TION SER VICE READ the engine operating and maintenance instruc- tions supplied with this machine. OIL This unit is supplied from the factory with the engine crankcase filled with a high quality SAE 10W/30 oil. This oil should be acceptable for most typical ambient temperatures.
BA TTER Y CHARGING The Classic 300G is equipped with a wet charged bat- tery. The charging current is automatically regulated when the battery is low (after starting the engine) to a trickle current when the battery is fully charged.
B-1 OPERA TION B-1 SAFETY PRECAUTIONS Operate the welder with the doors closed. Leaving the doors open changes the designed air flow and can cause overheating. GENERAL DESCRIPTION The Classic ® 300G is a heavy duty, engine driven, DC arc welding power source, capable of providing constant current output for stick welding or DC TIG welding.
• When hauling the welder between job sites, close the fuel feed valve beneath the fuel tank. • If the fuel supply is cut off or runs out while the fuel pump is operating, air may be entrapped in the fuel distribution system. If this happens, bleeding of the fuel system may be necessary.
B-3 OPERA TION B-3 CLASSIC 300G AUXILIARY POWER The AC auxiliary power, supplied as a standard, has a rating of 3.0 kVA of 115/230 VAC (60 hertz). With the 3.0 kVA, 115/230 VAC auxiliary power, one 115V duplex and one 230V duplex, grounding type receptacle are provided.
C-1 ACCESSORIES C-1 CLASSIC 300G OPTIONAL EQUIPMENT (Field Installed) Accessory Set (K704) - Includes 35 ft. (10.7m) elec- trode and 30 ft. (9.1m) work cables, headshield, work clamp and electrode holder. Pipe Thawing with an arc welder can cause fire, explosion, damage to electric wiring or to the arc welder if done improperly.
D-1 MAINTENANCE D-1 SAFETY PRECAUTIONS GENERAL INSTRUCTIONS • Blow out the welder and controls with an air hose at least once every two months. In particularly dirty locations, this cleaning may be necessary once a week. Use low pressure air to avoid driving dirt into the insulation.
D-2 MAINTENANCE D-2 Replace brushes when they wear within 1/4” of the pigtail. A complete set of replacement brushes should be kept on hand. Lincoln brushes have a curved face to fit the commutator.
D-3 D-3 CLASSIC 300G MAINTENANCE ENGINE SERVICE EVERY DAY OR EVERY 8 HOURS F I RST SERV ICE - (50 HOURS) EVERY 100 HOURS OR 3 MONTHS EVERY 200 HOURS OR 6 MONTHS EVERY 600 HOURS OR 12 MONTHS EN GINE SE.
E-1 TROUBLESHOOTING CLASSIC 300G E-1 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-2 TROUBLESHOOTING CLASSIC 300G E-2 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-3 TROUBLESHOOTING E-3 CLASSIC 300G Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-4 TROUBLESHOOTING CLASSIC 300G E-4 ELECTRONIC IDLER CONTROL TROUBLESHOOTING GUIDE Engine Will Not Return to Low Idle in Approximately 10 Seconds After Welding and Auxiliary Loads are Removed Set Idl.
E-5 TROUBLESHOOTING CLASSIC 300G E-5 ELECTRONIC IDLER CONTROL TROUBLESHOOTING GUIDE With Idler Control Switch in the AUTO Position,Engine Will Not Pick Up Speed When: Auxiliary Load 1. Load too small. Try load above 150 Watts. 2. Check for loose or disconnected wire running from black lead out of exciter to CB2 circuit breaker.
E-6 TROUBLESHOOTING CLASSIC 300G E-6 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-7 TROUBLESHOOTING CLASSIC 300G E-7 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-8 TROUBLESHOOTING E-8 CLASSIC 300G Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
F-1 DIAGRAMS F-1 CLASSIC 300G NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement.
F-2 DIAGRAMS F-2 CLASSIC 300G NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement.
F-3 DIAGRAMS F-3 CLASSIC 300G S26097 A RESIST ORS Y X B G W F G ORANGE WHITE JUMPER WHITE JUMPER PIN CA BLE CONNEC TION TABLE C D E LEAD COLOR RED BLUE CV "WIRE" CONTROL POT CCW BLUE RED ORA.
F-4 DIAGRAMS F-4 CLASSIC 300G PART NO. WELDER A B C D E F G H S10766-9 J K L CLASSIC 300G S10766 1/03 METRIC cm (ENGLISH in.) 170.0 (66.91) 146.6 (57.70) 22.1 (8.70) 58.4 (23.00) 67.0 (26.38) 34.3 (13.50) 105.8 (41.66) 8.26 (3.25) 115.6 (45.5) A CONTROL PANEL F G B H D E C O HOLE O MOUNTING HOLE N.
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE PARA ESTE EQUIP AMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
Een belangrijk punt na aankoop van elk apparaat Lincoln Electric 10659 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lincoln Electric 10659 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lincoln Electric 10659 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lincoln Electric 10659 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lincoln Electric 10659 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lincoln Electric 10659 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lincoln Electric 10659 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lincoln Electric 10659 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.