Gebruiksaanwijzing /service van het product 400FM van de fabrikant Lincoln Electric
Ga naar pagina of 25
MA GNUM 300FM and 400FM Fast-M ate ™ Gun and Cable Assemblies OPERA T ORʼS MANUAL IM389-C March, 2008 Safety Depends on Y ou Lincoln arc welding and cutting equipment is designed and built with safety in mind. However , your overall safety can be increased by proper installation .
i SAFETY i MAGNUM® F AST -MA TE™ FOR ENGINE powered equipment. 1.a. T urn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ii SAFETY ii MAGNUM® F AST -MA TE™ ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87.
iii SAFETY iii MAGNUM® F AST -MA TE™ FOR ELECTRICALL Y powered equipment. 8.a. T urn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer ʼs recommendations.
iv SAFETY iv MAGNUM® F AST -MA TE™ PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L ʼArc 1.
MAGNUM® F AST -MA TE™ v v Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
Page General DescriptIon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section A Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GENERAL DESCRIPTION Description Gun Contact Tips Gas Product Cable Wire Size Standard Diffuser Gas Cable Gun T ube Number Length (m) in. (mm) Duty Assembly Nozzle Insulator Liner 60° 10 ft. .035 (0.9) KP14-35 K478-1 (3.0) .045 (1.2) -45 KP54A KP24A-62 KP34A KP44-3545-15 KP1928-2 15 ft.
GENERAL DESCRIPTION MAGNUM® F AST -MA TE™ Description Gun Contact Tips Gas Product Cable Wire Size Standard Diffuser Gas Cable Gun T ube Number Length (m) in. (mm) Duty Assembly Nozzle Insulator Liner 60° 10 ft. .035 (0.9) KP14-35 K479-1 (3.0) .045 (1.
INST ALLA TION INST ALLA TION ELECTRICAL SHOCK can kill. • Have an electrician install and ser- vice this equipment. • T urn the input power off at the fuse box before working on equipment.
OPERA TION OPERA TION ELECTRODES AND EQUIPMENT The Magnum® 300 FM and Magnum® 400 FM guns and cables have been designed for use with Lincoln L- 50 and L-56, solid steel wire electrodes for the GMA W process and Lincoln Outershield ® cored electrodes for the gas-shielded FCA W process.
MAGNUM® F AST -MA TE™ REMOV AL, INST ALLA TION AND TRIMMING INSTRUCTIONS FOR MAGNUM® LINERS FEEDING STEEL WIRE (KP1933, KP1936 and KP1955 series liners) NOTE: The variation in cable lengths prevents the interchangeability of liners.
MAGNUM® F AST -MA TE™ This screw should only be gently tightened. Overtightening will split or collapse the liner and cause poor wire feeding. ------------------------------------------------------------------------ 6. Replace the nozzle insulator and gas nozzle.
MAINTENANCE CABLE REP AIR The Magnum® 300 FM and Magnum® 400 FM guns feature the use of repairable cable connectors. If the cable ever gets severely damaged, it may be cut short- er and repaired by the user .
FIGURE E.4 MAINTENANCE MAGNUM® F AST -MA TE™ CABLE CONTROL LEAD INNER TUBE COPPER STRANDING CONTROL LEAD 1.65 (41.9 mm) SKIN * USE .38" (9.5 mm) SKIN FOR - FEEDER END OF FM MODELS .25" (6.4 mm) SKIN *- (BOTH CONTROL LEADS) FIGURE E.2 FIGURE E.
4.10 (104 mm) Terminal Lead Assembly Cable Handle Central Adapter Assembly Collar Nut Incoming Connector Assembly Connector Nut Cable Boot Strain Relief Strain Relief Housing Boot Nut - FIGURE E.5 MAINTENANCE e) Remove the incoming connector from the cable by unscrewing the connector nut from the incoming connector .
MAINTENANCE MAGNUM® F AST -MA TE™ THREAD SIZES FOR MAGNUM® 300 & 400 CONSUMABLES D-6 D-6.
TROUBLESHOOTING MAGNUM® F AST -MA TE™ If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
TROUBLESHOOTING MAGNUM® F AST -MA TE™ Observe all Safety Guidelines detailed througout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
TROUBLESHOOTING MAGNUM® F AST -MA TE™ Observe all Safety Guidelines detailed througout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
NOTES MAGNUM® F AST -MA TE™.
MAGNUM® F AST -MA TE™ NOTES.
W ARNING AV I S O D E PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING AV I S O D E PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIP AMENTO E AS P AR TES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 441 17-1 199 U.S.A. TEL: 216.481.8100 F AX: 216.486.1751 WEB SITE: www .
Een belangrijk punt na aankoop van elk apparaat Lincoln Electric 400FM (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lincoln Electric 400FM heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lincoln Electric 400FM vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lincoln Electric 400FM leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lincoln Electric 400FM krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lincoln Electric 400FM bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lincoln Electric 400FM kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lincoln Electric 400FM . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.