FOR ENGINE pow ered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ARC R A Y S can bur n. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.
FOR ELECTRIC ALL Y pow ered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8 . b . Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.
PRÉC A UTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1.
ix ix Thank Y ou for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
x x T ABLE OF CONTENTS Page Installation .......................................................................................................................Section A Technical Specifications ........................................................
A -1 INS T ALLA TION IDEALARC® DC-1000 A -1 60% Duty Cycle 215/108 86 215/124/108 124/94 113 TECHNICAL SPECIFICA TIONS – DC-1000 Volts at Rated Amperes 44 44 44 Auxiliary Power See the OPERATION se.
A-2 INS T ALLA TION IDEALARC® DC-1000 A-2 A permanent lifting eye is located at the top of the machine and is positioned so that it acts as nearly as possible through the center of gravity. This lift eye fits under the case of the second machine without interference when stacking.
A-3 INS T ALLA TION IDEALARC® DC-1000 A-3 RECONNECT PROCEDURE Multiple voltage machines are shipped connected to the highest input voltage listed on the machine’s rating plate. Before installing the machine, check that the Reconnect Panel in the Input Box Assembly is con- nected for the proper voltage.
A-4 INS T ALLA TION IDEALARC® DC-1000 A-4 FIGURE 2 FIGURE 3.
A-5 INS T ALLA TION IDEALARC® DC-1000 A-5 OUTPUT CONNECTIONS Output Studs The output leads are connected to the output termi- nals. The output terminals are located on the lower case front and labeled “+” and “-”.
B-1 OPER A TION IDEALARC® DC-1000 B-1 PRODUCT DESCRIPTION The DC-1000 is an SCR-contr olled three phase DC power source. It is designed with a single range potentiometer control for submerged arc or open arc automatic and semiautomatic welding. It can be used for air carbon arc cutting with carbon rods up to and including 5/8” (15.
B-2 INS T ALLA TION IDEALARC® DC-1000 B-2 Remote Output Control - (Optional) The K775 Remote Output Control consists of a control box with 28 ft. (8.4m) of four conductor cable. This connects to terminals 75, 76, 77 on the terminal strip, and the case grounding screw so marked with the symbol on the machine.
B-3 INS T ALLA TION IDEALARC® DC-1000 B-3 3. N A - 5 - Set the DC-1000 mode switch to the proc ess bein g us ed - CV (I) Inner shie ld or C V(S) Sub Arc.
D-1 MAINTENANCE D-1 The control board is designed with adequate protec- tion so that no damage will occur if the remote control l ea d s a r e s h o r te d to g e th e r o r ar e g r o u nd e d t o th e case. The machine will automatically shut down if such faults do occur.
E-1 TR OUBLESHOO TING E-1 IDEALARC® DC-1000 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-2 TR OUBLESHOO TING E-2 IDEALARC® DC-1000 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-3 TR OUBLESHOO TING E-3 IDEALARC® DC-1000 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-4 TR OUBLESHOO TING E-4 IDEALARC® DC-1000 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-5 TR OUBLESHOO TING E-5 IDEALARC® DC-1000 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-6 TR OUBLESHOO TING E-6 IDEALARC® DC-1000 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-7 TR OUBLESHOO TING E-7 IDEALARC® DC-1000 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
F-1 DIA GR AMS F-1 IDEALARC® DC-1000 CONNECTION OF DC-1000 WITH NL OPTION KIT TO LAF-3 (Obsolete) N.A. On all DC-1000 and DC-1500 units with codes above 8234 extend lead 67 and connect it to the electrode cable going to the automatic equip- ment. N.B.
F-2 DIA GR AMS F-2 IDEALARC® DC-1000 CONNECTION OF DC-1000 WITH NL OPTI ON KIT TO L T -3 or L T -34 (Obsolete) N.A. On all DC-1000 and DC-1500’s above Code 8234 extend lead 67 and connect it to the electrode cable going to the automatic equipment. N.
F-3 DIA GR AMS F-3 IDEALARC® DC-1000 CONNECTION OF DC-1000 to NA-5 N.A. Welding cables must be of proper capacity for the cur- rent and duty cycle of immediate and future applica- tions. N.B. Extend lead 21 using #14 or larger insulated wire phys- ically suitable for the installation.
F-4 DIA GR AMS F-4 IDEALARC® DC-1000 CONNECTION OF DC-1000 TO LN-7 CONNECTION OF DC-1000 TO LN-9 N.A. Welding cables must be of proper capacity for the current and duty cycle of immediate and future applications. N.B. Extend lead 21 using #14 or larger insulated wire physically suit- able for the installation.
F-5 DIA GR AMS F-5 IDEALARC® DC-1000 DC-1000 WIRING DIAGRAM FOR CODES 9919 - 9925, 10293, 1 1305, 1 1330, 1 1331, 1 1332, 1 1333, 1 1334 NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels.
F-6 DIA GR AMS F-6 IDEALARC® DC-1000 NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement.
NO TES IDEALARC® DC-1000.
NO TES IDEALARC® DC-1000.
NO TES IDEALARC® DC-1000.
W ARNING A VISO DE PREC A UCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INS TR UCTION FOR THIS EQUIPMENT AND THE CONSUMABLES T O BE USED AND FOLL O W Y OUR EMPL O YER’S SAFETY PRA CTICES.
W ARNING A VISO DE PREC A UCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREEND A AS INS TR UÇÕES DO F ABRIC ANTE P ARA ES TE EQUIP AMENT O E AS P ARTES DE USO , E SIGA AS PRÁTIC AS DE SE GURANÇA DO EMPRE GADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
Een belangrijk punt na aankoop van elk apparaat Lincoln Electric IM420-D (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lincoln Electric IM420-D heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lincoln Electric IM420-D vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lincoln Electric IM420-D leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lincoln Electric IM420-D krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lincoln Electric IM420-D bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lincoln Electric IM420-D kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lincoln Electric IM420-D . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.