Gebruiksaanwijzing /service van het product IM463-A van de fabrikant Lincoln Electric
Ga naar pagina of 34
DC-650 PRO OPERA TOR’S MANUAL Multiprocess DC P o w er Source For use with machines having Code Numbers 9814, 9836 and 9839 Only. IM463-A May, 2000 Safety Depends on You Lincoln arc welding equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation .
– 2 – PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH. KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.
– 3 – FOR ENGINE powered equipment. 7.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. --------------------------------------------------------------------------------------- 7.
-4- PR É CA UTIONS DE S Û RET É Pour votre propre protection lire et observer toutes les instructions et les pr é cautions de s û ret é specifiques qui parraissent dans ce manuel aussi bien que les pr é cautions de s û ret é g é n é rales suivantes: S û ret é Pour Soudage A L ’ Arc 1.
– 5 – T ABLE OF CONTENTS Page GENERAL DESCRIPTION ..................................................................................................................7 SPECIFICATIONS ..................................................................
– 6 – Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
– 7 – GENERAL DESCRIPTION The DC-650 PRO is a multiprocess DC power source designed for the GMAW (MIG), FCAW, SMAW (Stick), and SAW (Sub-Arc) processes, with arc gouging capability as well. It features an international industrial rating of 700 amps, 44 volts at 100% duty cycle.
INST ALLA TION Please read all of this section before starting installation. Refer to Figure 1 during installation. Location Place the welder where clean cooling air can freely circulate in through the front louvers, and out through the rear louvers.
– 9 – Figure 1.
– 10 – Table 1 208V / 60 Hz 230V / 60 Hz 460V / 60 Hz 575V / 60 Hz 200V / 50/60 Hz 220V / 50/60 Hz 380V / 50/60 Hz 400V / 50/60 Hz 415V / 50/60 Hz 440V / 50/60 Hz 500V / 50/60 Hz 130 117 59 47 138.
There are two pairs of studs for the negative connection. It is important to use the correct pair of studs, depending on the processes in use. NOTE: DO NOT CONNECT BOTH PAIRS OF NEGATIVE STUDS TOGETHER. USE EITHER ONE PAIR, OR THE OTHER, BUT NEVER CONNECT BOTH PAIRS TO THE WORKPIECE AT THE SAME TIME.
leads A, B, and C, connect A to 75, B to 76 and C to 77, connect lead 2 to terminal 2, lead 4 to terminal 4, etc. Connect the green ground lead to the stud marked .
– 13 – Connection of a K775 Remote Output Control Feed the remote control cable through the box connector on the case front, to provide a strain relief for the cable. Connect the numbered leads in the control cable to the like numbered terminals on the right hand terminal strip (75 to 75, 76 to 76, and 77 to 77).
12. Wire Feeder Receptacle This is the standard Lincoln, 14-pin, MS-type (amphenol) receptacle. See the DC-650 PRO wiring diagram for the pinout diagram of this receptacle. 13. Rating Plate This plate contains important information regarding the code number, serial number, input voltages, input currents, and output ratings of the DC-650 PRO.
– 15 – OPERA TING INSTRUCTIONS ELECTRIC SHOCK can kill. • Do not touch electrically live parts or electrode with skin or wet clothing. • Insulate yourself from work and ground. • Always wear dry insulating gloves. ------------------------------------------------------------------------ FUMES AND GASES can be dangerous.
SA W (Submerged Ar c) Operation Properly connect a wire feeder control cable to either the terminal strip or to the Wire Feeder Receptacle. If welding electrode positive, connect the electrode cable to the “ + ” output studs, and connect the work cable to the “ - ” studs labeled “ SMAW,SAW ” .
SMA W (Stic k) Operation If welding electrode positive connect the electrode cable to the “ + ” output studs, and connect the work cable to the “ - ” studs labeled “ SMAW,SAW ” . If welding electrode negative, reverse the connections. Do not make any connections to the center pair of output studs.
Set the control panel switches as follows: ------------------------------------------------------------------------ Mode: GMAW ------------------------------------------------------------------------ .
– 19 – P ower Source T roubleshooting Most welding equipment problems, particularly in new installations, can be traced to incorrect installation or incorrect procedures. Be sure that the DC-650 PRO is properly connected, all accessories and wire feeders are working correctly, and that valid welding procedures are being used.
– 20 – TROUBLE A. Input contactor chatters. B. Machine input contactor does not operate. C. Machine input contactor operates, but no output when trying to weld. D. Machine has high output and no control. CA USE 1. Faulty input contactor. 2. Low line voltage.
– 21 – TROUBLE E. Machine has low output and no control. F. Machine does not have maximum output. G. Machine will not shut off. H. Variable or sluggish welding arc. CA USE 1. Output control Local/Remote switch in wrong position. 2. Output control switch faulty.
– 22 – TROUBLE I. Output control not functioning on the machine. J. Output control not functioning on remote control. K. Digital meters do not light - or - Digital meter display is incorrect. L. Poor arc striking with semiautomatic wire feeders. CA USE 1.
– 23 – TROUBLE M. Poor arc characteristics in GMAW mode. N. Ammeter displays “ Err ” and Voltmeter displays a number CA USE 1. Capacitor bank not switching in. 2. Capacitor(s) in output circuit failed. A failure is indicated if the small vent plug on top of a capacitor is raised or blown out.
– 24 – TR OUBLESHOO TING Observe all Safety Guidelines detailed througout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
– 25 – If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
Protection PC Board The protection PC Board is located on the back of the control box. It protects the PC Board from electrical noise. Most of the circuits on the Protection board are straight through connections. The board can be checked out in the field with a continuity tester or an ohmmeter.
– 27 – PL1 10/50W 50/100W 10K/2W 10K/2W S S 4-29-94C G REMOTE CONTROL RESISTORS = OHMS/WATT UNLESS OTHERWISE SPECIFIED ALL SWITCH WIRING VIEWED FROM REAR OF SWITCH (SEE DETAILS) RECONNECT PANEL T1.
– 28 – G A B 3.25 27.50 32.70 39.95 GAS CYLINDER SUPPORT .406 DIA. MTG. HOLES F C H E 22.25 20.00 27.87 N.A. - Optional K-842 Undercarriage also available. See next page. A C E D FRONT OF WELDER R P L M U* V * LOCATION OF .406 DIA. MOUNTING HOLES B S W* H* K J* DIMENSION PRINTS DC-650 PRO WITH A K817 UNDERCARRIA GE INCHES 38.
11-1-96 P-223 P-223 P AR TS LIST FOR DC-650 PR O AND DC-750 This par ts list is pr o vided as an informative guide onl y . This inf ormation was accurate at the time of printing.
NO TES.
Now A vailab le ...12th Edition The Procedure Handbook of Ar c Welding With over 500,000 copies of previous editions published since 1933, the Procedure Handbook is considered by many to be the “ Bible ” of the arc welding industry. This printing will go fast so don ’ t delay.
W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIP AMENTO E AS PAR TES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
Een belangrijk punt na aankoop van elk apparaat Lincoln Electric IM463-A (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lincoln Electric IM463-A heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lincoln Electric IM463-A vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lincoln Electric IM463-A leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lincoln Electric IM463-A krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lincoln Electric IM463-A bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lincoln Electric IM463-A kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lincoln Electric IM463-A . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.