Gebruiksaanwijzing /service van het product IM637-A van de fabrikant Lincoln Electric
Ga naar pagina of 40
PRO-CUT TM 55 OPERA TOR’S MANUAL IM637-A March, 2005 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operation on your part.
PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH. KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.
FOR ELECTRICALL Y powered equipment. 6.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 6.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s rec- ommendations.
NOTES.
iv SAFETY iv PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1.
Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
vi vi T ABLE OF CONTENTS Page Installation .......................................................................................................Section A Technical Specifications ......................................................................
vii vii T ABLE OF CONTENTS Page Maintenance ....................................................................................................Section D Safety Precautions ..............................................................................
A-1 INST ALLA TION A-1 RA TED OUTPUT OUTPUT RECOMMEND INPUT WIRE AND FUSE SIZES REQUIRED GAS FLOW RA TE REQUIRED GAS INLET PRESSURE TECHNICAL SPECIFICA TIONS - PRO-CUT 55 Duty Cycle 50% Duty Cycle 100% Duty Cycle Current Range 25-60 Amps Open Circuit V oltage MAX 335 VDC For all plasma cutting applications Based on U.
A-2 INST ALLA TION PRO-CUT 55 A-2 SAFETY PRECAUTIONS Read entire Installation Section before installing the PRO-CUT 55. ELECTRIC SHOCK CAN KILL. • Only qualified personnel should install this machine. • Turn the input power OFF at the disconnect switch or fuse box and discharge input capacitors before working inside the equip- ment.
A-3 INST ALLA TION PRO-CUT 55 A-3 INPUT ELECTRICAL CONNECTIONS Before installing the machine, check that input supply voltage, phase, and frequency are the same as the machine's voltage, phase, and frequency as specified on the machine's rating plate.
A-4 INST ALLA TION PRO-CUT 55 A-4 2. If the ground screw assembly is loose, tighten the assembly to the base before installing the new ground lead. Install the green lead on the ground screw assembly, replace the plain washer and lock washer, then tighten nut.
A-5 INST ALLA TION PRO-CUT 55 A-5 GAS INPUT CONNECTIONS Supply the PRO-CUT 55 with clean compressed air or nitrogen. • Supply pressure must be between 80 psi and 150 psi. • Pressure guage, located on the front of the machine, should be set to approximately 70 PSI for a 25 ft.
B-1 OPERA TION PRO-CUT 55 B-1 SAFETY PRECAUTIONS Read and understand this entire section before oper- ating the machine. NOTE: All P.C. boards are protected by a moisture resis- tant coating.
B-2 OPERA TION B-2 USER RESPONSIBILITY Because design, fabrication, erection and cutting vari- ables affect the results obtained in applying this type of information, the serviceability of a product or struc- ture is the responsibility of the user.
B-3 OPERA TION B-3 CUTTING CAP ABILITY The PRO-CUT 55 is rated at 55 amps, at 50% duty cycle on a 10 minute basis (runs 55 amps for 5 minutes, then idling for 5 minutes) or 40 amps, at 100% duty cycle (continuous use).
B-4 OPERA TION B-4 LIMIT A TIONS Do not exceed output current and duty cycle rating of machine. Do not use the PRO-CUT 55 for pipe thaw- ing. CONTROLS AND SETTINGS When preparing to cut or gouge, position the machine as close to the work as possible. Make sure you have all materials needed to complete the job and have taken all safety precautions.
B-5 OPERA TION B-5 • Hold the nozzle standoff 1/8 ” (3.2mm) to 3/16 ” (4.7mm) above the workpiece during cutting. Do not let the torch nozzle touch the work or carry a long arc. • Keep moving while cutting. Cut at a steady speed without pausing.
B-6 OPERA TION B-6 PILOT ARC DISCUSSION The PRO-CUT has a smooth, continuous pilot arc. The pilot arc is only a means of transferring the arc to the workpiece for cutting. Repeated pilot arc starts, in rapid succession, is not recommended as these starts will generally reduce consumable life.
B-7 OPERA TION B-7 Suggestions for Extra Utility from the PRO-CUT System: 1. Occasionally an oxide layer may form over the tip of the electrode, creating an insulating barrier between the electrode and nozzle. This will result in the tripping of the Pro-Cut's safety circuit.
C-1 ACCESSORIES C-1 AL W A YS USE GENUINE LINCOLN ELECTRIC ELECTRODES AND VORTECH ™ NOZZLES • Only Genuine Lincoln Electric consumables yield the best cutting performance for the PRO-CUT 55. • The patented VORTECH ™ nozzle provides an extra “ kick ” of swirl as the arc exits the nozzle which improves cutting performance.
D-1 MAINTENANCE D-1 PRO-CUT 55 INPUT FIL TER CAP ACIT OR DISCHARGE PROCEDURE 1 . Turn off input power or disconnect input power lines. 2. Remove the 5/16" hex head screws from the side and top of the machine and remove wrap-around machine cover. 3.
D-2 MAINTENANCE D-2 ROUTINE MAINTENANCE 1 . Keep the cutting or gouging area and the area around the machine clean and free of combustible materials. No debris should be allowed to collect which could obstruct air flow to the machine. 2 . Every 6 months or so, the machine should be cleaned with a low pressure airstream.
E-1 TROUBLESHOOTING E-1 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-2 TROUBLESHOOTING E-2 PRO-CUT 55 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-3 TROUBLESHOOTING E-3 PRO-CUT 55 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-4 TROUBLESHOOTING E-4 PRO-CUT 55 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-5 TROUBLESHOOTING E-5 PRO-CUT 55 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-6 TROUBLESHOOTING E-6 PRO-CUT 55 Observe all Safety Guidelines detailed throughout this manual ST A TUS BOARD INDICA TORS SYMPTOM Machine is unresponsive immediately after power-up.
E-7 TROUBLESHOOTING E-7 PRO-CUT 55 Observe all Safety Guidelines detailed throughout this manual CONSUMABLE RELA TED SAFETY LED TROUBLESHOOTING A. If the Safety LED is LIT AND STEADY , perform the following: 1. If the reset button (when pressed) does not turn the Safety LED off, the reset button or associated wiring may be faulty.
F-1 DIAGRAMS F-1 PRO-CUT 55 NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement.
F-2 DIAGRAMS F-2 PRO-CUT 55 NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement.
F-3 DIAGRAMS F-3 PRO-CUT 55 LEFT SIDE OF MAC HINE J5,J22,J36 J35 J4,J10, J1,J20, J33 ELECTRICAL SYMBOLS PER E1537 L12067 12 3 4 13 4 6 1 5 4 1 8 7 6 12 15 5 10 1 6 8 1 16 1 9 WIRING DIAGRAM (CODES 110.
F-4 DIAGRAMS F-4 PRO-CUT 55 ELEC ELEC xxxxxxx CONTROL S4 PRIMARY LEFT SIDE OF MAC HINE 360 J33 J37 S2 RESET J5,J22,J36 15 14 217 216 J35 223 J4,J10, S3 PSI_SET J1,J20, J33 54 B U R S1 V W R POWER W 53.
F-5 DIAGRAMS F-5 PRO-CUT 55 12.60 11.00 25.94 19.50 2.95 DIMENSION PRINT PR O-CUT 55 10-31-97D M18806 OFF OFF XXXX XXXX XXXX XXXX XXXX XXXX PRO-CUT 55.
NOTES PRO-CUT 55.
NOTES PRO-CUT 55.
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIPAMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
Een belangrijk punt na aankoop van elk apparaat Lincoln Electric IM637-A (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lincoln Electric IM637-A heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lincoln Electric IM637-A vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lincoln Electric IM637-A leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lincoln Electric IM637-A krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lincoln Electric IM637-A bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lincoln Electric IM637-A kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lincoln Electric IM637-A . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.