RED-D-ARC FX450 IM10094 February, 2011 Red-D-Arc Spec-Built W elding Equipment This RED-D-ARC welder is built to RED-D-ARC Extreme Duty design specifications by Lincoln Electric. Safety Depends on Y ou This welder is designed and built with safety in mind.
FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ii SAFETY ii ARC R A Y S can bur n. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
iii SAFETY iii FOR ELECTRIC ALL Y pow er ed equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.
iv SAFETY iv PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A LʼArc 1.
v v Thank Y ou for selecting one of our QUALITY products. We want you to take pride in operating this product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
vi vi T ABLE OF CONTENTS Page Installation .......................................................................................................Section A Technical Specifications ......................................................................
FX450 (RED-D-ARC) A-1 INST ALLA TION A-1 TECHNICAL SPECIFICA TIONS - FX450 RA TED OUTPUT POWER SOURCE-INPUT VOL T AGE AND CURRENT Model K3073-1 Duty Cycle 60% rating 100% rating Volts at Rated Amperes 36.
A-2 INST ALLA TION FX450 (RED-D-ARC) A-2 PHYSICAL DIMENSIONS TEMPERA TURE RANGES HEIGHT 18.80in (478mm) MODEL K3073-1 WIDTH 14.14in (359mm) DEPTH 26.66in (677mm) WEIGHT 125lbs (56.
A-3 INST ALLA TION A-3 SELECT SUIT ABLE LOCA TION LOCATION AND VENTILATION FOR COOLING Place the welder where clean cooling air can freely circulate in through the rear louvers and out through the case sides. Dirt, dust, or any foreign material that can be drawn into the welder should be kept at a mini- mum.
A-4 INST ALLA TION A-4 INPUT FUSE AND SUPPL Y WIRE CONSIDERA TIONS Refer to Specification in this Installation Section for recommended fuse, wire sizes and type of the copper wires.
A-5 INST ALLA TION A-5 FX450 (RED-D-ARC) Pin A B C D E F Wiring 77 Remote potentiometer, 5K 76 Remote potentiometer, wiper 75 Remote potentiometer, common Trigger, common Trigger, input Ground CABLE CONNECTIONS See FIGURE A.2 for locating 6-pin and 14-pin con- nectors on the front of the FX450.
A-6 INST ALLA TION FX450 (RED-D-ARC) A-6 RECOMMENDED ELECTRODE AND WORK CABLE SIZES FOR ARC WELDING General Guidelines Connect the electrode and work cables between the appropriate output studs of the FX450 per the follow- ing guidelines: • Most welding applications run with the electrode being positive (+).
B-1 OPERA TION FX450 (RED-D-ARC) B-1 SAFETY PRECAUTIONS Read this entire section of operating instructions before operating the machine. ELECTRIC SHOCK can kill.
B-2 OPERA TION B-2 FX450 (RED-D-ARC) PRODUCT DESCRIPTION The FX450 is a multi-process CC/CV DC inverter and is rated for 450 amps, 38 volts at a 60% duty cycle. This machine is intended for both factory and field operation. It comes in a compact, rugged case that is designed for portability and outdoor use with an IP23 environmental rating.
B-3 OPERA TION B-3 RECOMMENDED PROCESSES AND EQUIPMENT RECOMMENDED PROCESSES The FX450 is designed for CC-SMAW, CC-GTAW (lift tig), CV-GMAW, CV-FCAW-SS and CV-FCAW-GS welding processes. CAG (arc gouging) is also supported. PROCESS LIMIT A TIONS The FX450 is suitable only for the processes listed.
B-4 OPERA TION B-4 CASE FRONT CONTROL DESCRIPTIONS (See Figure B.1) 1. Power Switch 2. Voltage Display Meter 3. Amperage Display Meter 4. Thermal LED 5. Output Control Dial 6. Weld Process Selector Switch 7. Hot Start Toggle Switch 8. Output Control Local/Remote Toggle Switch 9.
B-5 OPERA TION B-5 FX450 (RED-D-ARC) CASE BACK CONTROL (See Figure B.2) 1. Input Power Cord Access Hole. 1 1 FIGURE B.2 COMMON WELDING PROCEDURES MAKING A WELD The serviceability of a product or structure utiliz- ing the welding programs is and must be the sole responsibility of the builder/user.
B-6 OPERA TION B-6 Amperage Display Meter • Prior to STICK or TIG operation (current flow), the meter displays preset current value. • Prior to CV operation, the meter displays four dash- es indicating non-presettable AMPS. • During welding, this meter displays actual average amps.
B-7 OPERA TION B-7 GT A W This weld mode is a constant current (CC) mode featuring con- tinuous control from 10 – 500 amps. It is intended for the GTAW TIG welding processes. Hot Start - The Hot Start control regulates the starting current at arc initiation.
B-8 OPERA TION B-8 CV -INNERSHIELD This weld mode is a constant voltage (CV) mode fea- turing continuous control from 10 to 45 volts. It is intended for the FCAW-SS welding process and arc gouging. Hot Start – Toggle to “ON” position to provide more energy during the start of a weld.
C-1 ACCESSORIES C-1 OPTIONS / ACCESSORIES General Options K2149-1 Work Lead Package. K1842-10 10ft. Weld Power Cable (Lug to Lug). Inverter and Wire Feeder Cart Rear-wheeled cart includes front casters and no-lift gas bottle platform. Convenient handles allow for easy cable storage while full length side trays store parts and tools.
D-1 MAINTENANCE D-1 PERIODIC MAINTENANCE Thermal Protection Thermostats protect the machine from excessive operating temperatures. Excessive temperatures may be caused by a lack of cooling air or operating the machine beyond the duty cycle and output rating.
E-1 TROUBLESHOOTING E-1 FX450 (RED-D-ARC) If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-2 TROUBLESHOOTING E-2 FX450 (RED-D-ARC) Observe all Safety Guidelines detailed throughout this manual PROBLEMS (SYMPTOMS) POSSIBLE CAUSE RECOMMENDED COURSE OF ACTION Major physical or electrical damage is evident when the sheet metal covers are removed.
E-3 TROUBLESHOOTING E-3 FX450 (RED-D-ARC) Observe all Safety Guidelines detailed throughout this manual USING THE ST A TUS LED TO TROUBLESHOOT SYSTEM PROBLEMS Errors are displayed on the user interface. In addition, there are status lights on the control pc board and the switch pc board that contain error sequences.
F-1 DIAGRAMS F-1 FX450 (RED-D-ARC) NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement.
F-2 DIMENSION PRINT F-2 FX450 (RED-D-ARC) L15698 A.01 26.66 18.78 14.14 26.51 13.06 L15698 A.01 26.66 18.78 14.14 26.51 13.06.
W ARNING A VISO DE PREC A UCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERS T AND THE MANUF A CTURER’S INS TRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLL O W Y OUR EMPL O YER’S SAFETY PRA CTICES.
W ARNING A VISO DE PREC A UCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREEND A A S INSTR UÇÕES DO F ABRIC ANTE P ARA ES TE EQUIP AMENT O E AS P AR TES DE USO , E SIGA AS PRÁTIC A S DE SEGUR ANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
Een belangrijk punt na aankoop van elk apparaat Lincoln Electric RED-D-ARC FX450 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lincoln Electric RED-D-ARC FX450 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lincoln Electric RED-D-ARC FX450 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lincoln Electric RED-D-ARC FX450 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lincoln Electric RED-D-ARC FX450 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lincoln Electric RED-D-ARC FX450 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lincoln Electric RED-D-ARC FX450 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lincoln Electric RED-D-ARC FX450 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.