Gebruiksaanwijzing /service van het product SP-100T van de fabrikant Lincoln Electric
Ga naar pagina of 35
SP- 100T OPERA TOR’S MANUAL IM811 September, 2004 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operation on your part.
FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.
iv SAFETY iv Mar. ‘93 PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1.
v v Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
vi vi MASTER T ABLE OF CONTENTS FOR ALL SECTIONS Page Installation .......................................................................................................Section A Technical Specifications ..............................................
A-1 SP-100T A-1 Fuse or Output Mode Input Voltage Breaker Size Input Amps Power Cord Extension Cord RATED 115V/60Hz 20 Amp 20 15 Amp, 125V, Three Conductor Three Prong Plug #14 AWG (NEMA Type 5-15P) (2.1 mm 2 ) or Larger Up to 25 Ft. (7.6 mm) CSA 115V/60Hz 15 Amp 15 15 Amp, 125V, Three Conductor Three Prong Plug #12 AWG (NEMA Type 5-15P) (3.
A-2 INST ALLA TION SP-100T A-2 Read entire installation section before starting installation. SAFETY PRECAUTIONS IDENTIFY AND LOCA TE COMPONENTS If you have not already done so, unpack the SP-100T from its carton and remove all packing material around the SP-100T.
A-3 INST ALLA TION SP-100T A-3 SP-100T 4 5 8 3 6 7 1 2 DO NOT SWITCH WHEN WELDING + - FIGURE A.2 Work Clamp Installation Attach the work clamp per the following: 1.
Work Cable Installation Refer to Figure A.2. 1. Open the wire feed section door on the right side of the SP-100T. 2. Pass the end of the work cable that has the termi- nal lug with the smaller hole through the Work Cable Access Hole (1) in the case front.
CYLINDER may explode if dam- aged. Keep cylinder upright and chained to support • Keep cylinder away from areas where it may be damaged. • Never lift welder with cylinder attached. • Never allow welding electrode to touch cylinder. • Keep cylinder away from welding or other live electrical circuits.
A-6 INST ALLA TION SP-100T A-6 INPUT CONNECTIONS Refer to Figure A.6. The SP-100T has a power input cable located on the rear of the machine. FIGURE A.6 CODE REQUIREMENTS FOR INPUT CONNECTIONS This welding machine must be connected to a power source in accordance with applicable elec- trical codes.
B-1 OPERA TION B-1 SP-100T Read entire operation section before operating the SP-100T . ELECTRIC SHOCK can kill. • Do not touch electrically live parts or electrode with skin or wet clothing. Insulate yourself from work and ground. • Always wear dry insulating gloves.
B-2 OPERA TION B-2 5. Gun Trigger - Activates welding output, wire feed, and gas solenoid operation. Releasing the trigger deactivates welding and simultaneously activates the “ burnback ” function so that the welding wire does not stick in the weld puddle.
B-3 OPERA TION B-3 WELDING OPERA TIONS SEQUENCE OF OPERA TION Wire Loading Refer to Figures B.2 and B.3. The machine power switch should be turned to the OFF ( “ O ” ) position before working inside the wire feed enclosure. The welder is shipped from the factory ready to feed 8" (200 mm) diameter spools with 2.
B-4 OPERA TION B-4 Friction Brake Adjustment With wire spool installed on the spindle shaft and the wing nut loose, turn the spool by hand while slowly tightening the wing nut until a light drag is felt.
B-5 OPERA TION B-5 FIGURE B.6 Making A Weld 1. See “ Process Guidelines ” in this section for selec- tion of welding wire and shielding gas and for range of metal thicknesses that can be welded. 2. See the Application chart on the inside of the wire feed compartment door for information on setting the SP-100T controls.
B-6 OPERA TION B-6 The SP-100T is suitable for .035" aluminum wire and .030" stainless wire. Refer to Table B.1 for recom- mended procedure settings (requires K499 Argon Regulator Kit). TABLE B.1 Note: NR-Not Recommended CHANGING MACHINE OVER T O FEED OTHER WIRE SIZES The SP-100T is shipped from the factory ready to feed .
B-7 APPLICA TION CHART B-7 SP-100T.
C-1 ACCESSORIES C-1 OPTIONAL ACCESSORIES 1. K549-1 .035" (0.9 mm) Innershield® Welding Kit — Includes a contact tip, a gasless nozzle and a .035/.045" (.9/1.2 mm) cable liner to permit the Magnum ™ 100L gun and cable to use .035" (0.
C-2 ACCESSORIES C-2 INNERSHIELD (FCA W) CONVERSION Several changes are needed to convert the unit for operation with the Innershield (FCAW) process. The K549-1 Innershield Kit include ’ s all the necessary accessories for this conversion and is provided for this purpose.
MAINTENANCE SAFETY PRECAUTIONS ELECTRIC SHOCK can kill. • Disconnect input power by removing plug from receptacle before working inside SP-100T. Use only grounded receptacle. Do not touch electrically “hot” parts inside SP-100T. • Have qualified personnel do the mainte- nance and trouble shooting work.
D-2 MAINTENANCE D-2 SP-100T GUN AND CABLE MAINTENANCE FOR MAGNUM™ 100L GUN Gun Cable Cleaning Clean cable liner after using approximately 300 lbs (136 kg) of solid wire or 50 lbs (23 kg) of flux-cored wire. Remove the cable from the wire feeder and lay it out straight on the floor.
D-3 MAINTENANCE D-3 SP-100T COMPONENT REPLACEMENT PROCEDURES CHANGING THE CONT ACT TIP 1. Refer to Figure D.2. Remove the gas nozzle from the gun by unscrewing counter-clockwise. 2. Remove the existing contact tip from the gun by unscrewing counter-clockwise.
D-4 MAINTENANCE D-4 CHANGING LINER NOTICE: The variation in cable lengths pre- vents the interchangeability of liners. Once a liner has been cut for a particular gun, it should not be installed in another gun unless it can meet the liner cutoff length requirement.
D-5 MAINTENANCE D-5 GUN HANDLE P ARTS The gun handle consists of two halves that are held together with a collar on each end. To open up the handle, turn the collars approximately 60 degrees counter-clockwise until the collar reaches a stop. Then pull the collar off the gun handle.
E-1 TROUBLESHOOTING E-1 SP-100T This Troubleshooting Guide is provided to help you locate and remedy possible prob- lems with machine setup or operation. Simply follow the three-step procedure listed below. Step 1. LOCATE PROBLEM (SYMPTOM). Look under the column labeled “ PROBLEM (SYMPTOMS) ” .
E-2 TROUBLESHOOTING E-2 SP-100T If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-3 TROUBLESHOOTING E-3 SP-100T If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-4 TROUBLESHOOTING E-4 SP-100T If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
F-1 DIAGRAMS F-1 SP-100T W ARNI NG HIGH VOLTAGE can kill Only qualified persons should install, Do not operate with covers removed. Disconnect input power by unplugging Do not touch electrically live par ts use or service this machine. power cord before ser vicing.
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIP AMENTO E AS PAR TES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
Een belangrijk punt na aankoop van elk apparaat Lincoln Electric SP-100T (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lincoln Electric SP-100T heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lincoln Electric SP-100T vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lincoln Electric SP-100T leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lincoln Electric SP-100T krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lincoln Electric SP-100T bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lincoln Electric SP-100T kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lincoln Electric SP-100T . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.