INVER TEC V200-T ® OPERA TOR’S MANUAL IM592 November, 1999 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operation on your part.
FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.
iv SAFETY iv PRÉCA UTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1.
Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
vi T ABLE OF CONTENTS Page Installation .......................................................................................................................Section A Technical Specifications .........................................................
A-1 INST ALLA TION INVERTEC V200-T A-1 TECHNICAL SPECIFICA TIONS - V200T TIG For DC TIG Welding at 200A/20% Duty Cycle Based on the 1996 U.S. National Electrical Code Code Number 10463 Volts at Rated .
A-2 INST ALLA TION INVERTEC V200-T A-2 MA CHINE GROUNDING AND HIGH FRE- Q UENCY INTERFERENCE PR O TECTION The welder must be grounded. See your local and national electrical codes for proper grounding methods.
A-3 INST ALLA TION INVERTEC V200-T A-3 a) A metal underground water pipe in direct con- tact with the earth for ten feet or more. b) A 3/4” (19mm) galvanized pipe or a 5/8” (16mm) solid galvanized iron, steel or copper rod driven at least eight feet into the ground.
A-4 INST ALLA TION INVERTEC V200-T A-4 OUTPUT CONNECTIONS Refer to Figure A.2 for the location of the output terminals. A quick-disconnect system using Twist-Mate TM cable plugs is used for the welding cable connections. The electrode and work cables will require these plugs.
A-5 INST ALLA TION INVERTEC V200-T A-5 SHIELDING GAS CONNECTION An adjustable gas pressure regulator and flow gage should be obtained. Obtain the necessary inert shield- ing gas (usually argon). Connect the cylinder of gas with the pressure regulator and flow gage.
B-1 OPERA TION INVERTEC V200-T B-1 Read and understand this entire section before operating your machine. SAFETY INSTR UCTIONS ELECTRIC SHOCK can kill. • Do not touch electrically live parts such as output terminals or internal wiring. • Insulate yourself from the work and ground.
B-2 OPERA TION B-2 INVERTEC V200-T Power Switch/Voltage Selector Switch - Controls the power input to the machine. This rotating switch is used to turn the machine on and off as well as to select the input voltage. The switch is located on the top right rear panel.
B-3 OPERA TION B-3 Start/Crater Potentiometer - This potentiometer is used to adjust the START CURRENT and CRATER CURRENT for TIG welding only. This potentiometer also adjusts the ARC FORCE when in STICK welding mode.
B-4 OPERA TION B-4 OPERA TING STEPS WELDING IN TIG MODE 1. Connect the TIG torch and cable quick connect plug to the DC- output receptacle. This receptacle also contains an integral gas connection for the torch. Connect the work cable to the DC+ recepta- cle and to the work piece.
B-5 OPERA TION B-5 WELDING IN STICK MODE 1. Put the electrode holder and cable quick connect plug into the proper receptacle for the electrode polarity desired. Turn clockwise until tight. Connect the work clamp to the other receptacle and the work piece.
B-6 OPERA TION B-6 EXPLANA TION OF 2 STEP AND 4 STEP MODES (See figure B.2 and the explanations that follow) 2 STEP 2 Step mode can be used with either an arc start switch or a hand or foot amptrol. The welding cycle begins when the torch switch is held closed and ends when the switch is released.
C-1 A CCESSORIES C-1 OPTIONAL A CCESSORIES K870 - Foot Amptrol tm for TIG welding. When the V200-T’s Output Control is in the “REMOTE” position, the foot Amptrol energizes the output and controls the output remotely. The Foot Amptrol connects directly to the 6 pin Amphenol.
D-1 MAINTENANCE D-1 INVERTEC V200-T SAFETY PRECA UTIONS ELECTRIC SHOCK can kill. • Have an electrician install and ser- vice this equipment. • Turn the input power off at the fuse box, disconnect supply lines and allow machine to sit for five minutes minimum to allow the power capaci- tors to discharge before working inside this equipment.
E-1 TR OUBLESHOO TING E-1 INVERTEC V200-T If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-2 TR OUBLESHOO TING E-2 INVERTEC V200-T Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
F-1 DIA GRAMS F-1 NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement.
P AR TS INVERTEC® V200-T P AR TS LIST FOR INVER TEC V200-T This par ts list is pr ovided as an inf ormative guide only . This inf ormation was accurate at the time of printing.
7-30-97 INVERTEC V-200-T Do Not use this Parts List for a machine if its code number is not listed. Contact the Service Department for any code numbers not listed. Use the Illustration of Sub-Assemblies page and the table below to determine which sub assembly page and col- umn the desired part is located on for your particular code machine.
11-4-98 INVERTEC V-200-T P-308-C P-308-C General Assembl y.
1 Solenoid Valve S24105-1 1 X 2 HF 91 High Frequency PCB (Adjusted 0.3mm) S24105-2 1 X (Not Shown) 3 High Frequency Transformer S24105-3 1 X 4 50 OHM 80 W Resistor (Faston Terminal) S24105-4 2 X 5 Pla.
INVERTEC V-200-T NO TES.
Now A vailab le...12th Edition The Procedure Handbook of Ar c W elding With over 500,000 copies of previous editions published since 1933, the Procedure Handbook is considered by many to be the “Bible” of the arc welding industry. This printing will go fast so don’t delay.
W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE PARA ESTE EQUIP AMENTO E AS P AR TES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
Een belangrijk punt na aankoop van elk apparaat Lincoln Electric V200-T (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lincoln Electric V200-T heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lincoln Electric V200-T vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lincoln Electric V200-T leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lincoln Electric V200-T krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lincoln Electric V200-T bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lincoln Electric V200-T kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lincoln Electric V200-T . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.