Gebruiksaanwijzing /service van het product VS-GSWG van de fabrikant Linear
Ga naar pagina of 34
VS-GSWG Swing Gate Oper ator Installation Guide USA & Canada (800) 421-1587 & (800) 392-0123 (760) 438-7000 - T oll Free FAX (800) 468-1340 www .
VS-GSWG Swing Gate Operator Installation Guide - ii - P1250 Revision X6 7-8-2011 T able of Contents Pre-installation Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Before Y ou Begin... . . . . . . . . . . . . . . . .
VS-GSWG Swing Gate Operator Installation Guide - 1 - P1250 Revision X6 7-8-2011 Pre-installation Information Before Y ou Begin... Bef ore unpacking, inspect the car ton f or exterior damage. If you fi nd damage, advise the deliv er y carrier of a potential claim.
VS-GSWG Swing Gate Operator Installation Guide - 2 - P1250 Revision X6 7-8-2011 Wiring Specifi cations Ref er to the follo wing steps for details on po wer and accessor y wiring for the operator . AC P ower Wiring 1. Find the listing on this page corresponding to the model, voltage and horsepower r ating of your operator .
VS-GSWG Swing Gate Operator Installation Guide - 3 - P1250 Revision X6 7-8-2011 Mounting P ad Installation The gate operator mounts bolted to posts secured in concrete f ootings. The posts suppor t the operator and pre vent it from mo ving dur ing operation.
VS-GSWG Swing Gate Operator Installation Guide - 4 - P1250 Revision X6 7-8-2011 Operator Prepar ation Vent Plug Installation In order to keep gear oil from spilling out during shipping, gear reducers used in gate operators ha ve either a solid plug, or a sealed v ent plug, installed at the factory .
VS-GSWG Swing Gate Operator Installation Guide - 5 - P1250 Revision X6 7-8-2011 Operator Setup Controller Access The Controller is protected by a plastic dust co ver . T o remov e the dust cov er , loosen the cov er’ s wing-screw and lift the cov er off (see Figure 5).
VS-GSWG Swing Gate Operator Installation Guide - 6 - P1250 Revision X6 7-8-2011 Operator Setup (cont.) Open and Close Limit Adjustment The limit nuts are not preset at the f actor y and must be adjusted f or the gate in each installation.
VS-GSWG Swing Gate Operator Installation Guide - 7 - P1250 Revision X6 7-8-2011 T orque Limiter Adjustment Bef ore adjusting the torque limiter , make sure the gate is in good working condition. With the gate disconnected from the gate ar m, one person should be able to mo ve the gate by hand.
VS-GSWG Swing Gate Operator Installation Guide - 8 - P1250 Revision X6 7-8-2011 Controller Features S HADOW/ R E S ET P R O GR AMMIN G B UTTON S POWE R INDICATO RS DI S PLAY WHIP ANTENNA OPE R ATION B.
VS-GSWG Swing Gate Operator Installation Guide - 9 - P1250 Revision X6 7-8-2011 Indicator Descriptions INDICA TOR DEFINITION INDICA TION WHEN LIT DURING NORMAL OPERA TION INDICA TION WHEN LIT DURING P.
VS-GSWG Swing Gate Operator Installation Guide - 10 - P1250 Revision X6 7-8-2011 T erminal Descriptions TERMINAL GROUP FUNCTION AC N 24 V OL T INPUT F ACT OR Y CONNECTED T O 24 V AC FR OM TRANSFORMER OR 24 VDC FROM CONTINUOUS DUTY DC SUPPL Y . AC DC - ACCESSOR Y POWER PRO VIDES 24 V OL T DC POWER FOR ACCESSORIES .
VS-GSWG Swing Gate Operator Installation Guide - 11 - P1250 Revision X6 7-8-2011 Operator Accessory Connections 3-BUTTON STATION KEYSWITCH FIRE ACCESS SWITCH SINGLE-CHANNEL RADIO RECEIVER WIRELESS GAT.
VS-GSWG Swing Gate Operator Installation Guide - 12 - P1250 Revision X6 7-8-2011 Basic Controller Programming Progr amming Overview The Controller can be programmed with v arious options for the operator . The programming fi elds are defi ned as “functions” that ha ve “options”.
VS-GSWG Swing Gate Operator Installation Guide - 13 - P1250 Revision X6 7-8-2011 Basic Controller Programming (Cont.) Run Alarm and Pre-start Alarm The factory default is Run Alarm on and a 3-second Pre-star t Alar m. The operator’ s beeper will sound 3 seconds before the operator star ts.
VS-GSWG Swing Gate Operator Installation Guide - 14 - P1250 Revision X6 7-8-2011 Advanced Controller Progr amming Entering Advanced Progr amming Mode T o access and program the Adv anced Programming functions, f or each programming session, Adv anced Programming must be enab led.
VS-GSWG Swing Gate Operator Installation Guide - 15 - P1250 Revision X6 7-8-2011 Advanced Controller Progr amming (Cont.) Auxiliary Relay Mode The Auxiliary Relay has normally open and normally closed contacts. The factory setting disables the A uxiliar y Relay .
VS-GSWG Swing Gate Operator Installation Guide - 16 - P1250 Revision X6 7-8-2011 Advanced Controller Progr amming (Cont.) Reset Cycle Count The Controller counts of the number of times the operator has been cycled full open and close. The cycle count can be displayed.
VS-GSWG Swing Gate Operator Installation Guide - 17 - P1250 Revision X6 7-8-2011 Advanced Controller Progr amming (Cont.) Radio T ransmitter Learn The Controller’ s built-in MegaCode® radio receiv er can store the IDs of up to 40 transmitters. Refer to the fi gure for the steps required to learn transmitters.
VS-GSWG Swing Gate Operator Installation Guide - 18 - P1250 Revision X6 7-8-2011 Loop Lay out Illustration.
VS-GSWG Swing Gate Operator Installation Guide - 19 - P1250 Revision X6 7-8-2011 Safety Edge Lay out Illustration W ARNING One or more contact sensors shall be located on the inside and outside leading edge of a swing gate.
VS-GSWG Swing Gate Operator Installation Guide - 20 - P1250 Revision X6 7-8-2011 Photoey e Installation Illustration.
VS-GSWG Swing Gate Operator Installation Guide - 21 - P1250 Revision X6 7-8-2011 Dual Gate Installations T wo operators can be used in dual gate installations. The operators communicate with each other through the 3-wire COMM LINK terminals. When one operator activ ates, the COMM LINK connection signals the other operator to activ ate.
VS-GSWG Swing Gate Operator Installation Guide - 22 - P1250 Revision X6 7-8-2011 Gate Operation Open Button Opens the gate. If the Controller is programmed to stop opening the gate at mid-tra vel, a constant press of the OPEN button will o verride the Mid-tra vel Stop and completely open the gate.
VS-GSWG Swing Gate Operator Installation Guide - 23 - P1250 Revision X6 7-8-2011 Error Indications During abnor mal operation, the Controller’ s displa ys and beeper will indicate the error condition that has occurred.
VS-GSWG Swing Gate Operator Installation Guide - 24 - P1250 Revision X6 7-8-2011 T roubleshooting Contacting T echnical Support For technical questions regarding Linear gate oper ators, contact the T echnical Ser vices Depar tment at: 1-800-421-1587 fr om 5:00 AM to 4:30 PM P acifi c time Operator fails to start A.
VS-GSWG Swing Gate Operator Installation Guide - 25 - P1250 Revision X6 7-8-2011 Prev entative Maintenance General Linear gate operators are designed f or many y ears of trouble-free oper ation and, under recommended operating conditions, will require only minimal maintenance .
VS-GSWG Swing Gate Operator Installation Guide - 26 - P1250 Revision X6 7-8-2011 Model VS-GSWG Exploded View.
VS-GSWG Swing Gate Operator Installation Guide - 27 - P1250 Revision X6 7-8-2011 MODEL SWG MECHANICAL P ARTS LIST REF . # P ART # DESCRIPTION 2120-361 Complete Enclosure Assembly with Door 1 2110-067 .
VS-GSWG Swing Gate Operator Installation Guide - 28 - P1250 Revision X6 7-8-2011 Controller P arts List S HADOW/ R E S ET OPEN/RESET 6 8 3 1 4 9 5 10 2 VS-GSWG CONTROLLER MECHANICAL P ARTS LIST REF .
VS-GSWG Swing Gate Operator Installation Guide - 29 - P1250 Revision X6 7-8-2011 V ariable Speed Drive Progr amming Progr amming the Hitachi Inverter 1. Apply pow er 2. Press FUNC 3. Use ▲▼ arrows to adv ance to F_ _ ( F002 f or L200) 4. Press FUNC arrow to get to F02 (L100 ONL Y) 5.
VS-GSWG Swing Gate Operator Installation Guide - 30 - P1250 Revision X6 7-8-2011 GA TE ARM ASSEMBL Y MECHANICAL P ARTS LIST REF . # P ART # DESCRIPTION 2110-648 Gate Ar m Assembly , 78” (complete) 1.
VS-GSWG Swing Gate Operator Installation Guide - 31 - P1250 Revision X6 7-8-2011 This page left blank intentionally ..
VS-GSWG Swing Gate Operator Installation Guide - 32 - P1250 Revision X6 7-8-2011 Gate Operator Installation Checklist ❑ ❑ 1. The gate has been chec ked to make sure it is le vel and mov es freely in both directions.
Een belangrijk punt na aankoop van elk apparaat Linear VS-GSWG (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Linear VS-GSWG heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Linear VS-GSWG vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Linear VS-GSWG leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Linear VS-GSWG krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Linear VS-GSWG bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Linear VS-GSWG kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Linear VS-GSWG . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.