Gebruiksaanwijzing /service van het product 8355 van de fabrikant Aprilaire
Ga naar pagina of 16
Important Safety Information Warning: • Always turn off power at the main power source by unscrewing fuse or switching circuit breaker to the off position before installing, removing, cleaning, or servicing thermostat. • Read all of the information in this manual before installing or programming this thermostat.
Features • Four pre-programmed setpoints for each day of the week. • Fast and easy programming for setting all days of the week simultaneously . • Energy efficient recovery . • Residual cooling for added air -conditioning efficiency . • T wo “AA” ENERGIZER brand batteries retain program memory, even during power outages.
FIGURE 1 Installing the Model 8355 Thermostat NOTE: For new installations, mount thermostat on inside wall, 4-5 feet above the floor . Do not install behind a door , in a corner , near air vents, in direct sunlight, or near any heat or steam generating fixtures.
FIGURE 3 7. Drill the marked holes using a 3/16" drill bit. NOTE: Enclosed plastic anchors do not require a drilled hole for drywall. 8. T ap plastic anchors into the holes. 9. Align base with plastic anchors and feed wires through opening. See Fig 4.
Programming Guide Set T ime of Day , Day of Week, T emperature Differential, Residual Cooling 1. Press SET & PROG/MAN. Release simultaneously . Press or to change T ime of Day . 2. Press 3. Press T o Change Day of Week 4. Press 5. Press T o change 1st Stage T emperature Differential NOTE: The T emperature Differential is Factory preset at 1°.
Changing Fahrenheit (F) to Celsius (C) Press and Hold SET Press Release both simultaneously . Energy Efficient Recovery The energy efficient recovery feature looks ahead up to 2 hours prior to the end of the setback (or set-up) period to begin monitoring pe rf or mance and calculating when to turn on your system.
Setting Daily Programming 1. Place COOL-OFF-HEA T -EM in COOL position. 2. Press SET button. The display will show a number from 1 to 7. This number represents the day of the week to be programmed. If programming individual days, press either or button to adjust the day of the week to program (1=Mon.
3. Press PROG/MAN button until indicator is in PROG position. T emporary Program Override T o temporarily increase or decrease temperature Press or The thermostat will automatically return to the program at the next scheduled setting change or after four hours.
T o T est Thermostat WARNING: DO NOT SHORT (JUMPER) ACROSS TERMINALS OF GAS V ALVE OR SYSTEM CONTROL TO TEST OPERA TION. THIS WILL DAMAGE THE THERMOST A T AND VOID YOUR W ARRANTY . CAUTION: Do not switch system to cool if the temperature is below 50°F (10°C).
T roubleshooting SYMPTOM REMEDY 10 Thermostat does not turn on system. Check Wiring (see INST ALLA TION). Check fuse. Replace with 3 amp fuse if fuse has opened. Five minute compressor short cycle protection may be in effect. Press RESET to override. NOTE: This will erase programming.
11 R Y1 O BG E W2 LC Y2 APRILAIRE MODEL 8355 HEAT PUMP THERMOSTAT R Y O G E W2 L C W3 CARRIER LOW VOLTAGE TERMINAL BOARD APRILAIRE MODEL 8355 HEAT PUMP THERMOSTAT CONVERSION TO CARRIER SPLIT SYSTEM CO.
12 R Y1 O BG E W2 LC Y2 APRILAIRE MODEL 8355 HEAT PUMP THERMOSTAT R Y O G W1 W2 X C COMFORTMAKER LOW VOLTAGE TERMINAL BOARD APRILAIRE MODEL 8355 HEAT PUMP THERMOSTAT CONVERSION TO COMFORTMAKER CYC SER.
13 R Y1 O BG E W2 LC Y2 APRILAIRE MODEL 8355 HEAT PUMP THERMOSTAT R Y O G W2 L C PAYNE LOW VOLTAGE TERM INAL BOARD APRILAIRE MODEL 8355 HEAT PUMP THERMOSTAT CONVERSION TO PAYNE RELIANT AND ENDURA MODE.
14 R Y1 O BG E W2 LC Y2 APRILAIRE MODEL 8355 HEAT PUMP THERMOSTAT R Y O G X2 W-U B WEATHERTRON LOW VOLTAGE TERMINAL BOARD APRILAIRE MODEL 8355 HEAT PUMP THERMOSTAT CONVERSION TO WEATHERTRON HEAT PUMPS.
15 R Y1 O BG E W2 LC Y2 APRILAIRE MODEL 8355 HEAT PUMP THERMOSTAT R Y O G E W1 L C T LENNOX LOW VOLTAGE TERMINAL BOARD APRILAIRE MODEL 8355 HEAT PUMP THERMOSTAT CONVERSION TO LENNOX CB19 HEAT PUMP SYS.
Limited Warranty Y our Research Products Corporation Aprilaire ® Thermostat unit is expressly warranted for two (2) years from date of installa- tion to be free from defects in materials and workmanship.
Een belangrijk punt na aankoop van elk apparaat Aprilaire 8355 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Aprilaire 8355 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Aprilaire 8355 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Aprilaire 8355 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Aprilaire 8355 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Aprilaire 8355 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Aprilaire 8355 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Aprilaire 8355 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.