Model 84 76 Thermostat with Event-Based ™ Air Cleaning READ AND SAVE THESE INSTRUCTIONS Safety & Installation Instructions.
2 3 Installation location recommendations ................................................................ 3 Outdoor temperature sensor (optional) ................................................................ 4 Thermostat mounting .................
4 5 OUTDOOR TEMPERA TURE SENSOR (OPTIONAL) Outdoor temperature can be measured by attaching an 8052 sensor to the S1 and S2 terminals. System setting #05 (Remote sensor) is used to enable sensor .
6 7 WIRING TERMINAL Wire specifications 18-24 gauge thermostat wire Installation notes • Ensure power at the HVAC equipment is off. • Loosen screw terminals, insert stripped wire and re-tighten. • Push the excess wire back into the opening and plug the wall opening to prevent drafts.
8 9 INST ALLA TION WIRING – SINGLE TRANSFORMER (USE JUMPER WIRE) FOR HEA T PUMP SYSTEM 1st AUX HEA TING 1st COMPRESSOR FA N REVERSE VA LV E FA ULT DETECT 2nd AUX HEA TING 2nd COMPRESSOR OUTDOOR TEMP.
10 11 SETUP & TESTING SYSTEM SETUP INSTRUCTIONS (CONTINUED) The Model 8476 thermostat has the option of being used in heat pump or heat/cool systems. Switch SW1 located on the back of the thermostat’ s face is used to select this. System setting number 00 will only be shown on these models to display the position of SW1.
12 13 SETUP & TESTING System setting Setting range, default in bold 09 1st stage differential 1°F (0.5°C) 1°F to 4°F (0.5°C to 2°C) 10 2nd stage differential 1°F (0.5°C) 1°F to 4°F (0.5°C to 2°C) 11 3rd stage differential (heat pump only) 1°F (0.
14 15 SYSTEM TEST MODE The system test mode is used to test a system after installation. The outputs of the thermostat can be manually activated one at a time to test their function. The following instructions show how to enter the test mode and turn outputs on and off.
16 17 SETUP & TESTING T est steps for Heat / Cool Step Key Input System Setting Display (Output) #2 01 HEA TING ON (W) 02 HEA TING ON (W2) 01 COOLING ON (Y) 02 COOLING ON (Y2) 01 FAN ON (G) #50 He.
18 19 QUICK REFERENCE TO CONTROLS & DISPLA Y NOTE: BACKLIGHT IS ACTIVA TED WITH FIRST BUTTON PRESS AND AUTOMA TICALL Y TURNS OFF . Includes Event-Base d ™ Air Cleaning CURRENT INDOOR TEMPERA TUR.
20 21 TROUBLESHOOTING DISPLA Y IS BLANK • Check circuit breaker and reset if necessary . • Make sure power switch at heating & cooling system is on. • Make sure furnace door is closed securely . • If thermostat is battery powered, make sure fresh AA alkaline batteries are correctly installed.
22 23 SPECIFICA TIONS Electrical Operating voltage 24 VAC (18 – 30 VAC) Current Maximum: 2.5A (total), 1.0A (single output) Maximum surge current: 5A Power supply Dual power . Can be battery or 24 VAC powered. When both the sources are available, battery will be used as back up power .
24 P.O. Box 1467 • Madison, WI 53701-1467 • Phone: 800/334-6011 • Fax: 608/257-4357 www.aprilairepartners.com 61000893 12.11 B2205693A Patent Pending © 2011 Aprilaire – A division of Research.
Een belangrijk punt na aankoop van elk apparaat Aprilaire 8476 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Aprilaire 8476 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Aprilaire 8476 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Aprilaire 8476 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Aprilaire 8476 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Aprilaire 8476 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Aprilaire 8476 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Aprilaire 8476 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.