Gebruiksaanwijzing /service van het product UVS33RN van de fabrikant Majestic Appliances
Ga naar pagina of 24
V ent-Free Gas Room Heaters: Models: UVS33RN, UVS33RP UVS36RN, UVS36RP Homeowner's Installation and Operating Instructions D E S I G N C E R T I F I E D GF454 UVC Cov er 2/27/97 2000221 1 3/06 Rev .
2 UVS33/36 V ent-Fr ee H eaters 2000221 1 Installation & Operating Instructions Important Curing/Burning Instructions ................................................................................. 3 Fireplace Dimensions ........................
3 UVS33/36 V ent-Fr ee H eaters 2000221 1 Installation & Operating Instructions annually . More frequent cleaning may be required due to excess lint and dust from carpeting, bedding material, etc. 6. Control compartments, burners and air passages in this heater should be kept clean and free of dust and lint.
4 UVS33/36 V ent-Fr ee H eaters 2000221 1 22 " 33" 29" 28" 5" 2 " Gas Line Access - 2" Dia. Finished W all Thickness Rough Opening Height Rough Opening Width Electrical Cable Knockout - 1" Dia.
5 UVS33/36 V ent-Fr ee H eaters 2000221 1 Clearance to Combustibles T op of unit to ceiling ................................. 36" (914 mm) Front of unit to combustibles .................... 36' (914 mm) Appliance T op .......................
6 UVS33/36 V ent-Fr ee H eaters 2000221 1 Hearth Extension A hearth extension in front of heater is recommended but not required. Planning Planning the installation is an important first step: it will save time and money later in the actual installation.
7 UVS33/36 V ent-Fr ee H eaters 2000221 1 Gas Specifications Model Fuel Gas Control Max. Min. Orifice Air Input Input Size Shutter BTU/H BTU/H Setting UVS33RN Nat Millivolt Hi/Lo 20,000 15,000 #45 1.
8 UVS33/36 V ent-Fr ee H eaters 2000221 1 T able 3 Gas supply pressures. Natural Gas LP Minimum Inlet Pressure 5.5" w .c. 1 1.0" w .c. Maximum Inlet Pressure 14.0" w .c. 14.0" w .c. Manifold Pressure 3.5" w .c. 10.0" w .c.
9 UVS33/36 V ent-Fr ee H eaters 2000221 1 NOTE: 1 10/120 electric power is required to operate blower (fan). Be sure to leave sufficient excess wire in case minor adjustments are required. Any electrical rewiring of this fan must be done by a qualified electrician.
10 UVS33/36 V ent-Fr ee H eaters 2000221 1 W584-9 WIRING DIAGRAM 1/8/99 djt 11/9/99 added thermopile Fig. 13 Remote switch wiring. W584-9 Thermopile FP381 DVT access door 12/99 FP381 Fig. 14 Installing remote switch bracket. Alternate Switch Location Remote switch can be installed on either side of the access door .
1 1 UVS33/36 V ent-Fr ee H eaters 2000221 1 Operating Instructions LG117 UVS33 logs 12/20/99 djt Fig. 17 UVS33 log placement. T op Left Log (A20) Rear Log (A19) T op Right Log (A21) Front Left L.
12 UVS33/36 V ent-Fr ee H eaters 2000221 1 First Firing Upon completing your gas line connection, a small amount of air will be in the lines. When first lighting unit with pilot light, it will take a few minutes to purge themselves of this air .
13 UVS33/36 V ent-Fr ee H eaters 2000221 1 T urn counterclockwise to increase flame height T urn clockwise to lower flame height HV102 Honeywell hi/lo knob 4/5/99 djt HV102 Fig. 18 Flame adjustment on gas valve. Fig. 19 Proper pilot flame height.
14 UVS33/36 V ent-Fr ee H eaters 2000221 1 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to " OFF ". Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. T urn OFF all electrical power to the fireplace.
15 UVS33/36 V ent-Fr ee H eaters 2000221 1 T roubleshooting • Gas Supply On • Supply line hooked up • Shutoff valve open NO NO NO NO • Lockout has engaged.
16 UVS33/36 V ent-Fr ee H eaters 2000221 1 Maintenance Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out.
17 UVS33/36 V ent-Fr ee H eaters 2000221 1 9 8 7 5a-f 17 11 21 6 4 3 13a/b 15 16 12 PILOT ON OFF PILOT AD J L O H I 1 1a 1b 1c 1d 1e 10 18a/b 2211 uvs33 parts 12/20/99 djt 20 14 22 19 25 2 22.
18 UVS33/36 V ent-Fr ee H eaters 2000221 1 Contact CFM Corporation for questions concerning prices and policies covering replacement parts. Parts may be ordered through your Majestic Fireplaces dis- tributor or dealer . Y ou will need the following information when ordering replacement parts: 1.
19 UVS33/36 V ent-Fr ee H eaters 2000221 1 Fan Kits FK12 Fan Kit This auxiliary fan system increases the efficiency of the circulation of the heating air . The FK12 Fan Assembly is a fixed speed fan system and does not allow for vari - able speed control.
20 UVS33/36 V ent-Fr ee H eaters 2000221 1 Decorative Frame T rims A selection of decorative frame trim kits are available for mounting around the outside of the appliance to en- hance its visual effect on the room. Installation instruc- tions for each decorative frame trim are included with the frame trim kit.
21 UVS33/36 V ent-Fr ee H eaters 2000221 1 Decorative Bay Window Available for the UVS36 only . When fitting the Bay Window Kit, the original front frame/glass assembly MUST remain in place. The Bay Window Kit is fit- ted over the existing front glass.
22 UVS33/36 V ent-Fr ee H eaters 2000221 1.
23 UVS33/36 V ent-Fr ee H eaters 2000221 1 BASIC W ARRANTY CF M Corporation (hereinafter referred to collective ly as the Company) warrants that your new V ermont Castings or Majestic Gas Fireplace/ S.
© CFM Corporation 2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www .cfmcorp.com CFM Corporation.
Een belangrijk punt na aankoop van elk apparaat Majestic Appliances UVS33RN (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Majestic Appliances UVS33RN heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Majestic Appliances UVS33RN vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Majestic Appliances UVS33RN leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Majestic Appliances UVS33RN krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Majestic Appliances UVS33RN bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Majestic Appliances UVS33RN kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Majestic Appliances UVS33RN . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.