Gebruiksaanwijzing /service van het product P-R185A to P-R405A, C-R185A to P-R405A, P-R185AL to P-R405AL, C-R185AL to C-R405AL, RP2100 van de fabrikant Aqua Products
Ga naar pagina of 43
Part No. 240612 CATALOG NO. 6000.52-Z Effective: 11-01-01 Replaces: 08-01-01 ® INST ALLA TION AND OPERA TING INSTRUCTIONS Models P-R185A to P-R405A C-R185A to P-R405A Low NOx P-R185AL to P-R405AL C-R.
TO WHOM IT MAY CONCERN: The new Raypak series RP2100 pool heaters have been designed to eliminate the need for conventional heat sinks (high temperature piping). The initial connection to the heater is made with a 2" PVC union adapter to which PVC may then be connected with appropriate cement.
CONTENTS 3 4 PART ONE OWNER'S OPERATING INSTRUCTIONS 4 SECTION 1 START-UP PROCEDURES 4 Before Start-Up 5 Lighting Instructions & Shut-Off Procedure (Manually Lighted Pilot MV) 6 Operating Ins.
P ART ONE - OWNER'S OPERA TING INSTRUCTIONS FOR YOUR SAFETY - READ BEFORE OPERATING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
4. Push the gas control knob slightly and turn clockwise to "Off". Do not force. 5. Replace heater door panel. 1. Set the thermostat to the lowest setting. 2. Turn On/Off switch to the "Off" position. 3. Remove heater door panel. TO TURN OFF GAS TO APPLIANCE A.
A. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand. B. BEFORE OPERATING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
AFTER START-UP Feel the inlet and outlet pipes. Outlet pipe should be only slightly warmer than the inlet. It should not be hot. WARNING: Should overheating occur or the gas supply fail to shut off, turn off the manual gas control to the appliance.
4. Make visual check of the burner and pilot flame. Flame pattern on the main burner and pilot is indi- cated in the previous illustration. Yellow flame means restriction of the air openings. Lifting or blowing flame indicates high gas pressure. Low flame means low gas pressure.
WINTERIZING THE POOL & SPA HEATER When heaters installed outdoors in freezing climate areas are to be shut down for the winter, observe the following step-by-step procedure: 1. Turn off gas valve, manual gas valve, and electrical supply to the heater.
12" Minimu m 12" M inimum 4" Minimum HEA TER Sheet Metal 24 Gauge SECTION 3 / INSTALLATION INSTRUCTIONS 10 IMPORTANT NOTICE These instructions are intended for the use of quali- fied personnel only, specifically trained and experienced in the installation of this type of heating equipment and related system components.
Heaters must not be installed under an overhang of less than three (3) feet from the top of the heater. Three (3) sides must be open in the area under the overhang. Roof water drainage must be diverted away from the heaters installed under overhangs with the use of gutters.
INDOOR HEATER The design is also certified for indoor installation when equipped with the approved draft hood. For Canada , indoor installation is restricted to an enclosure that is not occupied and does not directly communicate with occupied area. Refer to the latest edition of CAN/CGA-B149.
13 SPECIFICATIONS AND DIMENSIONS *Electrical Connection On Left Side is 19-1/8". a. All Air From Inside The Building: Each opening shall have a minimum net free square inches as noted: Model Square Inches Model Square Inches 185 1 8 1 335 333 265 2 6 4 405 399 b.
VENT PIPING WARNING: Indoor boilers require a drafthood that must be connected to a vent pipe and properly vented to the outside. Failure to follow this procedure can cause fire or fatal carbon monoxide poisoning.
Fig. # 8149 NOTE: Do not use teflon tape on gas line pipe thread. A flexible sealant is recommended. A minimum of 7" W.C. and a maximum of 14" W.C. upstream pressure under load, and no load conditions must be provided for natural gas or a minimum of 12" W.
Heater must be located so that any water leaks will not damage the structure of adjacent area. PVC pipe may be glued directly into header unions. FLOW RATES MODEL PIPE SIZE MIN.
17 PRESSURE RELIEF VALVE INSTALLATION To conform to local building codes, it may be necessary to install a pressure relief valve. A 3/4" pressure relief valve having a capacity equal to BTU/HR output of the model to be installed is recommended for this appliance.
RP2100+ Heat Exchanger Reversal Procedure (Capron Resin Header Models) 1. Remove right and left side access panels ( Figure 1). 2. Disconnect wires at high limit, AGS (automatic gas shutoff), and pressure switch on the inlet/outlet header ( Figure 2).
Fig. #4 Fig. #5 Fig. #3 JACO FITTING BULB & CLIP RE-INSTALLED IN/OUT HEADER ON OPPOSITE SIDE. 19.
ELECTRICAL WIRING NOTE : If it is necessary to replace any of the original wiring, it must be replaced with 105° C wire or its equivalent, and /or 150° C wire or its equivalent as originally built.
21 WIRING DIAGRAM KEY PINK CONNECTOR BLUE CONNECTOR Fig. # RP8096 *If required by Local Code, install at this location. Fig. #2353 For 120 V input power to the unit, connect the black wire to the “L1” or hot leg of the power supply . Connect the white wire to the “L2” or neutral leg of the power supply .
WIRING DIAGRAM - IID UNITS (atmospheric) 22.
WIRING DIAGRAM - IID UNITS (Low NOx) 23.
Control Panel Mounting Screws (4) Fig. #RP 8267 CONTROLS/ADJUSTMENTS/REPLACEMENTS Temperature Adjust Buttons Mode Button LCD Display Fig. #2000 MILLIVOLT CONTROLS The pool or spa water temperature is controlled by the pool heater thermostat on the upper front panel of the heater.
To adjust the desired pool or spa temperature setting, make sure the control is in the appropriate mode (POOL or SPA) and push the UP or DOWN buttons to get the desired set point temperature. If there is a safety fault, a fault code will be displayed along with a service indication.
RP2100 REMOTE CONTROL INSTALLATION CAUTION: Before installing remote controls to the RP2100 Digital Heater, read the following: The Raypak RP 2100 Digital Heater is remote ready in most cases. The digital liquid crystal (LCD) display shows the actual pool temperature, operating status, and service codes (See examples below).
PRESSURE SWITCH The pressure switch, or heater actuator, insures that the heater operates only when the filter pump is in operation. It is located on the inlet/outlet header.
BURNER DRAWER REMOVAL 1. Shut off main electrical power switch to heater. 2. Shut off gas upstream of heater. 3. Remove front door. 4. Disconnect gas line from gas valve. 5. Remove (2) screws that mount burner tray to unit, and (2) screws that secure gas valve to jacket.
TUBE CLEANING PROCEDURE Establish a regular inspection schedule, frequency depending on local water condition and severity of service. Do not let the tubes clog up solidly. Clean out deposits over 1/16" in thickness. The heater may be cleaned from the return header side, without breaking pipe connections.
The Raypak Low Nox Pool Heaters are certified and tested under the ANSI Z21.56.CSA 4.7 Standards for gas fired pool heaters. The heater should be installed to meet all local codes, the latest editions of the National Fuel Gas Code Z223.1 and the National Electrical Code, ANSI/NFPA 70.
31 BURNER DRA WER REMOV AL 1. Shut off main electrical power switch to heater . 2. Shut off gas up stream of heater . 3. Remove front door . 4. Disconnect gas line from gas valve. 5. Remove (2) screws that mount burner tray to the base of the unit, and (2) screws that secure gas valve to jacket.
MECHANICAL (FOR QUALIFIED SERVICE PERSONNEL ONLY) IMPORTANT NOTICE These instructions are primarily intended for the use of qualified personnel specifically trained and experienced in the installation of this type of heating equipment and related system components.
If pilot burner remains lit. Jump across pressure switch terminals If main burner does not fire, remove jumper Check for adequate water flow from filter Replace pressure switch Jump across thermostat If main burner fires, remove jumper If main burner does NOT fire.
WARNING HIGH VOLTAGE For qualified Technicians ONLY NOTE: Some heaters may be equipped with an ignition module that shuts off pilot gas if pilot fails to light. To reset, interrupt power to heater. Intermittent Pilot System TROUBLESHOOTING HONEYWELL S8600 NOTE:Before troubleshooting, familiarize yourself with the startup and checkout procedure.
35.
SECTION 6/REPLACEMENT PARTS LIST NOTE: To supply the correct part it is important that you state the model number, serial number and type of gas when applicable.
37.
38 Fig. #8124 Honeywell MV Fig. #8107 Fig. #9369 13-P 5-P 16-P 15-P 1-P 9-P 3-P Low NOx BURNER TRAY PILOT ASSEMBLIES 14-P 16-P 3-P 7-P 16-P 3-P 17-P Honeywell IID Atmospheric units for units produced .
39.
40.
41.
LIMITED WARRANTY RAYPAK RESIDENTIAL SWIMMING POOL AND SPA HEATERS GAS MODELS 185, 265, 335 & 405 MILLIVOLT 185, 265, 335 & 405 ELECTRONIC GENERAL Raypak, Inc.
Raypak, Inc. , 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 FAX (800) 872-9725 Raypak Canada LTD , 2805 Slough Street, Mississauga, Ontario, Canada L4T 1G2 (905) 677-7999 FAX (905) 677-8036 Raypak Australia Pty. Ltd , 7 Geddes St., Mulgrave, Victoria, Australia 3170 (6139) 560 4944 FAX (6139) 560 4974 Litho in U.
Een belangrijk punt na aankoop van elk apparaat Aqua Products P-R185A to P-R405A, C-R185A to P-R405A, P-R185AL to P-R405AL, C-R185AL to C-R405AL, RP2100 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Aqua Products P-R185A to P-R405A, C-R185A to P-R405A, P-R185AL to P-R405AL, C-R185AL to C-R405AL, RP2100 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Aqua Products P-R185A to P-R405A, C-R185A to P-R405A, P-R185AL to P-R405AL, C-R185AL to C-R405AL, RP2100 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Aqua Products P-R185A to P-R405A, C-R185A to P-R405A, P-R185AL to P-R405AL, C-R185AL to C-R405AL, RP2100 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Aqua Products P-R185A to P-R405A, C-R185A to P-R405A, P-R185AL to P-R405AL, C-R185AL to C-R405AL, RP2100 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Aqua Products P-R185A to P-R405A, C-R185A to P-R405A, P-R185AL to P-R405AL, C-R185AL to C-R405AL, RP2100 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Aqua Products P-R185A to P-R405A, C-R185A to P-R405A, P-R185AL to P-R405AL, C-R185AL to C-R405AL, RP2100 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Aqua Products P-R185A to P-R405A, C-R185A to P-R405A, P-R185AL to P-R405AL, C-R185AL to C-R405AL, RP2100 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.