W ARNING : Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer , service agency or the gas supplier .
2 This well engineered, gas water heater has all the fea- tures a water heater should have: It operates on the principle of heating water instantaneously “on demand”. When a hot water faucet is opened, cold water flows through the coils of the heat exchanger in the Aquastar .
3.
4 If you are using the AquaStar for combined space heating and potable water heating (see schematic diagram below) , all piping and other components connected to the system must be suitable for potabl.
5 4. Y ou must vent your heater. See section on V ent Pipe Connections, Page 5. 5. The appliance must be disconnected from the gas supply piping system during any pressure testing at pressures in excess of 1/2 Psig (3.
6 CLEARANCES The Aquastar 125 B is design certified for installation on a combustible wall and for installation in an alcove with the minimum clearances to combustible and non -combustible construction listed below A. T op 12 inches ( 305 mm) B. Front Open C.
7 The flue connection for the AquaStar 125B is 5 inches. However , in Canada, for installations at high altitude (2000- 4500 feet above sea level) a six inch flue is required. A 5" by 6" flue adaptor must be affixed to the flue collar of the AquaStar with at least two screws.
8 OPERA TING INSTRUCTIONS Before proceeding with the operation of the heater make sure that the system is filled with water . Make sure the water heater drain plug is closed. See Figure 7 below . Fig. 7 - W ater heater drain plug Open the cold water inlet supply to the heater fully .
9 LIGHTING INSTRUCTIONS 1. STOP! Read the safety information above on this plate. 2. The Gas valve must be turned off by sliding the gas valve button to the far left under the OFF ( ) mark. 3. W ait five (5) minutes to clear out any gas. If you smell gas, STOP! Follow “B” in the safety information above on this plate.
10 TROUBLE SHOOTING Introduction The AquaStar 125 burners are activated by a water flow valve. Numerous water related problems can cause this water valve to malfunction such as: Insufficient water flo.
11 6 . Faulty thermocouple (part #8747202083) or electromagnet ) Unless these 2 parts are at least 8 to 10 years old, it is very unlikely that they are faulty . Before testing, reconfirm that #2 is absolutely correct, and that all connections are clean and tight.
12 PILOT LIGHT GOES OUT DURING OR IMMEDIA TEL Y AFTER HOT W A TER HAS BEEN USED 1. Gas pressure too low V ery low gas pressure may be caused by low delivered gas pressure, a jammed gas regulator or undersized gas lines. If the gas lines are undersized, there may still be the specified static gas line pressure.
13 Fig. 1 1 - Diagram of AquaStar 125 B 5 11 1 4 9 10 1. Heat exchanger 2. Pilot assembly 3. Burner manifold gas pressure test nipple 4. Main gas burner 5. Pilot gas tubing 6. Gas valve 7. Pressure tap screw location 8. Gas control slide 9. Piezo igniter 10.
14 Fig. 12 - INTERIOR COMPONENTS DIAGRAM AND P ARTS LIST.
15 Fig. 12 INTERIOR COMPONENTS DIAGRAM AND P ARTS LIST 125B 1 Cover ¤ 8 705 421 025 2 Plastic collar ¤ 8 700 403 008 3 T emperature adjustment knob ¤ 8 702 000 1 1 1 4 Panel back ¤ 8 705 402 164 5.
Replacement Parts available from North American Distributor CONTROLLED ENERGY CORP . 340 Mad River Park V ermont 05673 (U.S.A.) Phone 800-642-31 1 1 Fax (802) 496-6924 WWW .CECHOT .COM VULCANO T ermodomésticos S.A. Estrada de Cacia 3800 Cacia - PORTUGAL Recycled paper techsupport@cechot.
Een belangrijk punt na aankoop van elk apparaat AquaStar 125B LP (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen AquaStar 125B LP heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens AquaStar 125B LP vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding AquaStar 125B LP leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over AquaStar 125B LP krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van AquaStar 125B LP bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de AquaStar 125B LP kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met AquaStar 125B LP . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.