Part #MAN152 Rev. 1.0 V.90-CL High Performance V .90/V .34+/V .42bis 56K BPS PCI Internal V oice/F AX/Data/ Speakerphone Modem User's Manual Contents Section One - Introduction .......................... 1 Section T wo - Installation ............
The information contained in this manual has been validated at the time of this manual's production. The manufacturer reserves the right to make any changes and improvements in the product de- scribed in this manual at any time and without notice.
1 Section One - Introduction The MaxTech XPVS56P/C PCI Plug and Play Data, Fax, Voice Speakerphone Modem connects your com- puter to all popular high speed modems available today. The modem utilizes V.90 (56Kbps) technology to provide increased download speeds using regular telephone lines.
2 2.3 Hardware Installation Installation of this modem requires opening and manipulating your PC. Exercise caution at all times when working with AC powered and static-sensitive equip- ment.
3 2 . 4 Hardware Configuration The version of Windows 9x you have will determine which set of dialog boxes is presented to you when installing the modem in Windows 9x. Proceed to one of the following sections, depending on your Windows 9x's diaglog box: • Section 2.
4 2.4.1.2 Windows 98 When Windows 98 starts for the first time after card installation, it detects the adapter and displays the Add New Hardware Wizard.
5 software. Consult the software manual for information on using these and other parameters/features. 115,200 bps; 8 data bits; no parity; 1 stop bit; RTS/CTS flow control set to “on;” initializat.
6 2.8 Where To Go From Here You should familiarize yourself with the functions available from the included software by reading its manual. You will be accessing most, if not all, of the modem's functions from this software. You may also use any other commercially available communication soft- ware with the modem.
7 3.3 Basic AT Commands In the following listings, all default settings are printed in bold text. Command Function A Manually answer incoming call A/ Repeat last command executed. Do not precede A/ with AT or follow with ENTER AT Appears at the beginning of every command line B_ B0 CCITT mode B 1 Bell mode B2 V.
8 I 5 Modem chip hardware configuration I 6 Country code I 7 Board manufacturer firmware version I 8 Modem firmware version I 1 0 Modem board configuration L_ L0 Low speaker volume L1 Low speaker volu.
9 X1 Same as X0 plus all CONNECT responses/ blind dialing X2 Same as X1 plus dial tone detection X3 Same as X1 plus busy signal detection/ blind dialing X 4 All responses and dial tone and busy signal.
10 &Q_ &Q 0 Modem in asynchronous mode &S_ & S0 Force DSR Signal High (ON) &S1 DSR is off in command mode, on in on-line mode &T _ &T 0 Ends test in progress &T 1 Perform Local Analog Loopback Test &U_ &U 0 Enable Trellis Coding @ V.
11 % E 1 V.22bis auto-retrain enabled %E 2 Enable line signal quality monitor and fallback/fallforward % G_ % G0 Enable Auto Fall Forward/Back %G1 Disable Auto Fall Forward/Back -C _ -C 0 Calling tone disabled -C1 1300hz calling tone -C2 V.8 and 1300hz calling tones enabled 3.
12 Default is 5 N_ N 0 Normal data-link only N 1 Normal data-link only N 2 MNP data link only N 3 V.42/MNP/Normal data link N 4 V.42 data link only O Initiate reliable link during a normal link Q_ Q0 .
13 +FTH=n Transmit HDLC data +FTM=n Transmit data +FTS=n Stop transmission and pause 3.7 ISO 101 Voice Mode Commands +FCLASS=8 Voice modem select +FLO Flow control select +VBT=n Buffwe threshold setti.
14 Table 4-1 S - Registers Register Function Range/units Default S0 Auto-answer Ring 0-255/rings 0 S1 Ring counter 0-255/rings 0 S2 Escape code character 0-127/ASCII 4 3 S3 Carriage return character 0.
15 CONNECT 33600 6 6 CONNECT 37333 3 4 CONNECT 38400 2 8 CONNECT 41333 3 5 CONNECT 42666 3 6 CONNECT 44000 3 7 CONNECT 45333 3 8 CONNECT 46666 3 9 CONNECT 48000 4 2 CONNECT 49333 4 3 CONNECT 50666 5 3.
16 Modem does not dial. 1 . Make sure the modem is connected to a working phone line. Replace the modem with a working phone to ensure that the phone line is working. Modem dials but does not connect. 1 . Make sure the IRQ setting is identical on both the modem AND the software.
17 Modem experiences bursts of errors or suddenly disconnects while communicating with a remote modem. 1 . Make sure Call Waiting is turned off. 2 . Make sure the phone line does not exhibit excess noise.
18 the FCC. Your telephone company may make changes in its facilities, equipment, operations, or procedures that could affect proper operation of your equipment. If they do, you will be notified in advance to give you an opportunity to maintain uninterrupted telephone service.
19 Before installing this equipment, users ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an accept- able method of connection.
Een belangrijk punt na aankoop van elk apparaat MaxTech PCI Internal Voice/FAX/Data/Speakerphone Modem (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen MaxTech PCI Internal Voice/FAX/Data/Speakerphone Modem heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens MaxTech PCI Internal Voice/FAX/Data/Speakerphone Modem vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding MaxTech PCI Internal Voice/FAX/Data/Speakerphone Modem leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over MaxTech PCI Internal Voice/FAX/Data/Speakerphone Modem krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van MaxTech PCI Internal Voice/FAX/Data/Speakerphone Modem bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de MaxTech PCI Internal Voice/FAX/Data/Speakerphone Modem kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met MaxTech PCI Internal Voice/FAX/Data/Speakerphone Modem . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.