Gebruiksaanwijzing /service van het product xpvs336i van de fabrikant MaxTech
Ga naar pagina of 23
Part #MAN081 Rev. 1.0 SF-1133HV/R12-PnP High Performance V .34+/V .42bis 33,600 BPS Internal Plug and Play F AX/V oice/Data Modem Featuring Advanced Full- Duplex Speakerphone Functions User's Man.
Contents Section One Introduction ........................... 1 Section Two Installation ............................. 1 Section Three AT Command Set ................. 7 Section Four S Registers ............................ 13 Section Five Result Codes .
1 Section One - Introduction This 33.6 Kbps Plug and Play FAX/Voice/Data Speakerphone Modem connects your computer to all popular high speed modems available today.
2 or, 2. If running DOS or Windows 3.x, configure the modem using the included modem driver. Instructions for installing this driver are included in the text file called README.1ST on the Windows 95 driver disk. The README.1ST file can be viewed by loading it into any wordprocessor or any text editor (i.
3 6. Replace the computer cover and plug in your com- puter. 7. Connect the telephone cable from the modem's LINE connector to the telephone wall jack. See Figure 2-2. 8. Optionally, connect your telephone to the modem's PHONE connector. 9. Optionally, connect your microphone to the modem's MIC jack.
4 The Install From Disk dialog box now instructs you to “Insert the manufacturer's installation disk into the drive selected, and then click OK.” Insert the modem's Utility diskette into the disk drive and type A: (or B: if inserted in drive B) in the “Copy manufacturer's files from:” box.
5 MANAGER|MAIN|CONTROL PANEL , click on PORTS and follow Windows 3.1x user's manual instructions on configuring the installed modem COM port. Proceed to Section 2.5, Software Installation/Con- figuration. 2.5 Software Installation and Configuration You are now ready to install and configure the communication software.
6 2. 7 Testing Your Modem After Installation In order to test your modem you should be familiar with your communication software. Load and set up your communication software and enter into “terminal mode.” Make sure that the COM Port and IRQ settings of the modem match the software.
7 Section Three - AT Command Set 3.1 Executing Commands Commands are accepted by the modem while it is in Command Mode. Your modem is automatically in Command Mode until you dial a number and establish a connection. Commands may be sent to your modem from a PC running communication software or any other terminal devices.
8 @ wait for five seconds of silence ! flash ; return to Command Mode after dialing DS=n Dial one of the four telephone numbers (n=0-3) stored in the modem’s non-volatile memory.
9 W 1 Report line speed, error correction protocol, and DTE speed. W 2 Report DCE speed only X _ X 0 Hayes Smartmodem 300 compatible responses/blind dialing.
10 &P2 Same as &P0 setting but at 20 pulses per minute &P3 Same as &P1 setting but at 20 pulses per minute &R_ &R 0 Reserved & R 1 CTS operates per flow control requirement.
11 300, 33600. Parameter “ a ” specifies the modulation protocol desired where: 0=V.21, 1=V.22, 2=V.22bis, 3=V.23, 9=V.32, 10=V.32bis, 11=V.34, 64=Bell 103, 69=Bell 212, and 74=VFC. Parameter “ b ” specifies automode operations where: 0=automode disabled, 1= automode enabled with V.
12 N 3 V.42/MNP/Normal data link N4 V.42 data link only N5 MNP data link only 3. 6 Fax Class 1 Commands +FAE=n Data/Fax Auto Answer +FCLASS=n Service Class +FRH=n Receive data with HDLC framing +FRM=n Receive data +FRS=n Receive silence +FTH=n Transmit data with HDLC framing +FTM=n Transmit data +FTS=n Stop transmission and wait 3.
13 +FPTS= Page Transfer Status +FREV? Identify Revision +FSPL Enable polling +FTSI: Report the Transmit Station ID 3.8 Voice Commands #BDR Select Baud Rate #CID Enable Caller ID detection and reportin.
14 Table 4-1 S - Registers Register Function Range/units Default S0 Auto-answer Ring 0-255 /rings 0 S1 Ring counter 0-255 /rings 0 S2 Escape code character 0-127 /ASCII 43 S3 Carriage return character.
15 S49-81 Reserved S82 Break options 3, 7, or 128 12 8 S83-85 Reserved S86 Connection failure code 0, 4, 5, 9, 12, 13, 14 * S87-S90 Reserved S91 Transmit attenuation 0-15/dBm 10 S92 Fax attenuation 0-.
16 data to it. Similarly, IRQ settings must be set correctly to receive data from the modem. 2. Make sure that your modem is initialized correctly. Your modem may have been initialized to not display re- sponses. You may factory-reset the modem by issuing AT&F and press ENTER .
17 and XON/XOFF software flow control is disabled in the communication software. 3. Make sure the data speed is not faster than your computer's capability.
18 Power: 0.75 W Temperature: 0 to 55 degrees C (Operating) Caller ID: Y e s PnP: Revision 1.0a Speakerphone: Full-duplex with DSP echo cancellation Appendix B - FCC , DOC & Other Notices FCC Compliance This equipment complies with Part 68 of the FCC Rules.
19 cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of.
20 to a telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the sum of the Load Numbers of all the devices does not exceed 100.
21.
Een belangrijk punt na aankoop van elk apparaat MaxTech xpvs336i (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen MaxTech xpvs336i heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens MaxTech xpvs336i vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding MaxTech xpvs336i leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over MaxTech xpvs336i krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van MaxTech xpvs336i bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de MaxTech xpvs336i kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met MaxTech xpvs336i . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.