PCI-DAS1002 Multifunction Analog & Digit al I/O User's Guide Document Revision 4, July, 2007 © Copyright 2007 , Measurement Computing Co rporation.
Your new Measurement Computing produc t comes with a fantastic extra — Management committed to your satisfaction! Refer to www.mccdaq.com/execteam.html for the names, titles, an d contact inform ation of each ke y executive at Measurement Computing.
Trademark and Copyright Information TracerDAQ, Universal Library, Harsh E nvironment Warranty , Measurement Compu ting Corporation, an d the Measurement Computing logo are either trademarks or registered trademarks of M easurement C omputing Corporation.
Table of Contents Preface About this U ser's Gu ide .......................................................................................................................7 What you will learn from this user's guide .........................
PCI-DAS1002 User's Manual Miscella neous ................................................................................................................................................... 22 Power consumption ....................................
Preface About this User's Guide What you will learn from this user's guide This user's guide explain s how to inst all, confi gure, and us e the PCI-DAS 1002 so that y ou get the most out of its analog, digital, and timing I/O features.
Chapter 1 Introducing the PCI-DAS1002 Overview: PCI-DAS1002 features This manual explains how to install and u se the PCI-DAS1002. This board is a multifunctio n analog and digital I/O board desi gned f or the PCI bus. The PCI-DAS1002 p rovides either 16 single-ended or eight differential analog inputs.
PCI-DAS1002 User's Manual Introducing the PCI-DAS1002 PCI-DAS1002 block diagram PCI-DAS1002 functions are illustrated in the block diagram shown here.
Chapter 2 Installing the PCI-DAS1002 What is included with your PCI-DAS1002 As you unpack your board, make s ure each of the items shown bel ow is included: Hardware PCI-DAS1002 Additional documentation In addition to this hard ware user's guide, you shoul d also receive the Quick Start Guide (available in PDF at www.
PCI-DAS1002 User's Manual Installing the PCI-DAS1002 Signal termination a nd conditioning accessories MCC provides signal terminatio n and conditioning products for use with the PCI-D AS1002. Refer to the " Field wiring and signal ter mination " section for a complete list of com patible accessory products.
PCI-DAS1002 User's Manual Installing the PCI-DAS1002 Configuring the hardware All hardware configuration options on the PCI-DAS1002 are software c ontrolled.
PCI-DAS1002 User's Manual Installing the PCI-DAS1002 Pinout – main I/O connector 8-channel differential mode Signal Name Pin Pin Signal Name GND 100 • • 50 GND N/C 99 • • 49 N/C N/C 98 • • 48 PC +5V N/C 97 • • 47 N/C N/C 96 • • 46 N/C A/D Int.
PCI-DAS1002 User's Manual Installing the PCI-DAS1002 16-channel single- ended mode Signal Name Pin Pin Signal Name GND 100 • • 50 GND N/C 99 • • 49 N/C N/C 98 • • 48 PC +5V N/C 97 • • 47 N/C N/C 96 • • 46 N/C A/D Int.
PCI-DAS1002 User's Manual Installing the PCI-DAS1002 Cables 1 50 2 49 51 100 52 99 100 50 51 1 Key Key The re d stri pe ide nt i fi es pi n # 1 The r ed stripe iden ti fies pi n # 51 Ca ble is la be led “Pins 5 1-100 ”. Cable i s lab eled “Pins 1- 50”.
Chapter 3 Programming and Developing Applications After following the installatio n instructions in Ch apter 2 , your board should now be inst alled and ready for use. Although the b oard is part of the larger D AS family , in general there may be no c orrespondence among registers for different boards.
Chapter 4 Calibrating the Board Introduction Calibrate the board u sing the Insta Cal utility after the board has fully warmed up. The reco mmended warm-up time is 15 m inutes. For best results, cal ibrate the boa rd immedi ately before m aking critical measurements.
Chapter 5 Specifications Typical for 25 °C unless other wise specified. Specifications in italic text are guarantee d by design. Analog input Table 1.
PCI-DAS1002 User's Manual Specifications Accuracy Accuracies are l isted for a 20 0 kHz sam pling rate, 10 0 sample avera ge, single cha nnel operation, a 15 mi nute warm-up, and operational temperatures with in ±2 ° C of internal calibration temperature.
PCI-DAS1002 User's Manual Specifications Analog output Table 6. Analog output specifications D/A converter type AD7847AR or equivalent Resolution 12 bits Number of channels 2 Configuration Voltage output, single-ended Output range ±10 V, ±5 V, 0 to 10 V, or 0 to 5 V.
PCI-DAS1002 User's Manual Specifications Counters Table 9. Counter specific ations Parameter Specification Counter type 82C54 Configuration Two 82C54 devices.
PCI-DAS1002 User's Manual Specifications Digital input/output Table 10. DIO specifications Digital type 82C55 Number of I/O 24 (FIRSTPORTA Bit 0 through FIRSTPORTC Bit 7) 2 banks of 8 and 2 banks of 4 or 3 banks of 8 or Configuration 2 banks of 8 with handshake Input high voltage 2.
PCI-DAS1002 User's Manual Specifications Connector and pin out Table 16. Main connector specificatio ns Connector type 100-pin high-density Robinson Nugent Compatible cable C100FF-x, unshielde d ribbon cab le.
PCI-DAS1002 User's Manual Specifications 16-channel single-ended mode pin out Pin Signal Name Pin Signal Name 1 LLGND 51 FIRSTPORTA Bit 0 2 CH0 HI 52 FIRSTPORTA Bit 1 3 CH8 HI 53 FIRSTPORTA Bit 2.
Declaration of Conformity Manufacturer: Measurement Computing C orporation Address: 10 Commerce Way Suite 1008 Norton, MA 02766 USA Category: Electrical equi pment for m easur ement, cont rol and laboratory use.
Measurement Computing Cor poration 10 Comme rce Wa y Suite 1008 Norton, Massachusetts 02766 (508) 946-5100 Fax: (508) 946-9500 E-mail: info@mccdaq.com www.
Een belangrijk punt na aankoop van elk apparaat Measurement Specialties PCI-DAS1002 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Measurement Specialties PCI-DAS1002 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Measurement Specialties PCI-DAS1002 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Measurement Specialties PCI-DAS1002 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Measurement Specialties PCI-DAS1002 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Measurement Specialties PCI-DAS1002 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Measurement Specialties PCI-DAS1002 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Measurement Specialties PCI-DAS1002 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.