Gebruiksaanwijzing /service van het product PR0091 van de fabrikant Mercury
Ga naar pagina of 21
Mercur y 6-5 Stat – Installation & User Guide Mercury 6-5 5 Channel Thermost at Inst allation Guide For Product: - PR0091 En sur e t ha t a ll po wer is sw it ched of f b efore inst a lling or ma int a ini n g this product Revision 1.
Mercur y 6-5 Stat – Installation & User Guide Table of Contents: THE MERCURY RANGE .................................................................................................................................... 3 Description ...............
Mercur y 6-5 Stat – Installation & User Guide The Mer cury Rang e From Resource Data Managemen t This documentation refers to the Mercury 6-5 - 5 Channel Thermostat Description The Mercury 5 Channel Thermostat ha s 5 thermostat f unctions.
Mercur y 6-5 Stat – Installation & User Guide Connections All connections are ma de to the back of the controller. The dia gram below shows the connection detail. Inputs and outputs are assigne d according to the chosen config uration. See Specification for further details on connectio ns.
Mercur y 6-5 Stat – Installation & User Guide Setting up the controller Access to the controller ca n be achieved several ways • Through the front mounted buttons • Direct access by PC or palm top into the rear co mms port. This requires a software package available on the RDM website • Through the RDM Data Directo r or Data Manager.
Mercur y 6-5 Stat – Installation & User Guide Recommended set-up method If you are not connecting to a network and want to set up the co ntroller through the buttons we recommend you use the following order from the function menu. rtc. Real time clock (This will automa tically synchronise on netw ork systems) a.
Mercur y 6-5 Stat – Installation & User Guide Parameter Tables: Parameter table for 5 Channel Thermosta t En sur e t ha t a ll po wer is Number Parameter Range o C ( o F ) Step Units Default P-01 Stat1 Temp Cut-In -49 to 30 o C (-56.2 to 86) 0.1 Deg 15.
Mercur y 6-5 Stat – Installation & User Guide Parameter table for 5 Channe l Thermostat Continued....... Number Parameter Range o C ( o F ) Step Units Default P-31 Stat4 Temp Cut-In -49 to 30 o C (-56.2 to 86) 0.1 Deg 15.0 P-32 Stat4 Diff 0 to 10 o C (32 to 50) 0.
Mercur y 6-5 Stat – Installation & User Guide Parameter table for 5 Channe l Thermostat Continued....... Number Parameter Range Step Units Default P79 Tuesday On Time 1 00:00 to 23:59 00:01 hh:m.
Mercur y 6-5 Stat – Installation & User Guide Network Configuration The final section to set-up is the network addres s. In all instance s, this mu st be done before the controller is plugged into the site network. The controllers have an aut o-initialise function, whic h will automatically log the device onto the site network.
Mercur y 6-5 Stat – Installation & User Guide Over-ride Operation The 5 Channel Thermostat can op erate either from its in ternal channel time settings or from a network Data Manager GP Timer channe l (P70 sets the mode either loca l or remo te).
Mercur y 6-5 Stat – Installation & User Guide Normal Operation During normal operation, the controlle r will display "on". If the 5 Channel Thermostat is on a network and on- line, the green network LED will be on . If any alarms are generated the r ed LED will light.
Mercur y 6-5 Stat – Installation & User Guide Thermostat Cooling/Heating Operation The diagrams below outline the operatio n of a channel when it is configured fo r he ating or cooling applications. In this instance the 5 Channel Thermo stat’s local timer is on.
Mercur y 6-5 Stat – Installation & User Guide Viewing Apart from setting up the controller, you can also view the status of the inputs a nd outputs. 1. IO. View Inputs / Outputs and States a. From the function menu, select “IO”, press enter b.
Mercur y 6-5 Stat – Installation & User Guide Network Alarms The table below shows the text and associated type numbe r that is se nt to the sy stem "front end".
Mercur y 6-5 Stat – Installation & User Guide Specification General Power requirements: Supply Voltage Range: 100 - 240 Vac ±10% Supply Frequency: 50 - 60 Hz ±10% Maximum supply current: <1 Amp (With no relay loads) Typical supply current: <0.
Mercur y 6-5 Stat – Installation & User Guide Inputs: Input resistance: 3.01K Ohms (for PTC or NTC type probes) Input type PT1000 NTC2000 N T C 2 k 2 5 Comms: RS232 with flow control En sur e t ha t a ll po wer is sw it ched of f b efore inst a lling or ma int a ini n g this product Revision 1.
Mercur y 6-5 Stat – Installation & User Guide Installation: Panel Cut-out: 72mm 93mm 34mm 17mm 2 holes: 3.5mm dia. Fixing: The controller can be fixed either by 2 X M3 screws fr om the re ar or by the plastic retaining de vice (PR0329), obtainable from RDM.
Mercur y 6-5 Stat – Installation & User Guide Wiring: Relay 4 and 5 N/O are fed from the supply input ! Note: Suitable mechanical restraints on the wi ring to the controller may be required; depen dant on cable types, to prevent undue stress or distorti on on the controlle r connectors.
Mercur y 6-5 Stat – Installation & User Guide Fuse: The host equipment must provide a suitable exter nal over-curre nt protection d evice such as: - Fuse: 6.
Mercur y 6-5 Stat – Installation & User Guide Revision History Revision Date Change s 1.0 27/10/2006 First Issue 1.1 01/03/2007 General Tidy Up 1.
Een belangrijk punt na aankoop van elk apparaat Mercury PR0091 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Mercury PR0091 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Mercury PR0091 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Mercury PR0091 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Mercury PR0091 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Mercury PR0091 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Mercury PR0091 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Mercury PR0091 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.