METROLOGIC INSTRUMENTS, INC. MS1890 Series Area Imaging Bar Code Scanner Installation and User’s Guide.
Copyright © 2007 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any for m or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Cop yright Act of 1976.
ii T ABLE OF C ONTENTS Introduction Product Overview ............................................................................................. 1 Scanner and Accessori es .............................................................................
iii T ABLE OF C ONTENTS Scanner and Cable T erminations Scanner Pinout Connecti ons .......................................................................... 31 Cable Connector C onfigurat ions ........................................................
1 I NTRODUCTION Product Overvie w The MS1890 is a rugged, hig h performance hand- held area imagi ng bar code scanner that utilizes a high-resolution CMOS imaging sensor for superior i mage quality. The MS1890 utiliz es Omniplanar, Inc.’s S wiftdecoder ® software for reliable decoding of both 1 D and 2D bar co de symbologie s.
2 I NTRODUCTION Scanner and Accessories B ASI C K IT Part # Description MS1890 Area Imaging Bar Code Scanner 00-02544 MetroSelect ® Single-Line Conf iguration Guide* 00-02281 Area Imaging Bar Code Su.
3 I NTRODUCTION Scanner and Accessories O PTIONAL A CCESSORIES Part # Description 53-53713 x -N-3 USB Full Speed Cable Locking Plus-Power™ Type A, 2.7 m (9 ft.) coiled cord, lo ng strain relief, black 53-53713 x -N-3 USB Full Speed Cable Locking Plus-Power™ Type A, 4.
4 I NTRODUCTION Scanner Components No. Item Description 1 Blue LED See Visual Indicators (on page 14) 2 White LED See Visual Indicators (on page 14) 3 Yellow LED See Visual Indicators (on page 14) 4 R.
5 I NTRODUCTION The PowerLink Cable Connecting Important: If the Pow erLink cable is n ot fully latched, the unit can power intermittently. Figure 2. Connecting the PowerLink Cable 1. Insert the 10-pi n RJ45 end of the cable into the socket on the MS1890.
6 I NTRODUCTION Labels Each scanner has a label loc ated on the underside of the hea d. This label provides the unit’s model number, date of manufacture, serial number, CE, and caution information. The follo wing figur e gives an example of the lab el and its location.
7 I NSTALLING THE S CANNER TO THE H OST S YSTEM RS232 MS1890-14 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS1890. There will be an audible click when the connector lock engages. 3.
8 I NSTALLING THE S CANNER TO THE H OST S YSTEM Keyboard Wedge MS1890-47 1. Turn off the host device. 2. Plug the 10-pin RJ45 male end of the PowerLink cable into 10-pi n socket on the MS1890. There will be an audible click when the connector lock engag es.
9 I NSTALLING THE S CANNER TO THE H OST S YSTEM Stand Alone Keyboard MS1890-47 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS1890. There will be an audible click when the connector lock engages.
10 I NSTALLING THE S CANNER TO THE H OST S YSTEM IBM MS1890-11 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the MS1890. There will be an audible click when the connector lock engages. 3. Slide the protective cable boot up the cable, over the connector and onto the end of scanner handle.
11 I NSTALLING THE S CANNER TO THE H OST S YSTEM Integrated USB: Full Speed MS1890-40 Low Speed MS1890-38 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the USB cable into the 10-pin socket on the MS1890. There will be an audible click when the connector lock engag es.
12 S CANNER O PERATION Multi-Try Trigger Mode* 1. The IR detects an object in the IR activation range and automatically turns on linear illuminatio n. 2. Aim the scanner’s line of light over the bar code. 3. Pull the trigger to initiate scanning. The scanner’s light output will start to flash as it attempts to scan the bar code.
13 S CANNER O PERATION Audible Indicators When the MS1890 is in operation, it pr ovid es audible feedb ack. These sounds indicate the status of the scanner. Eight settings are availab le for the tone of the beep (normal, 6 alternate tones and no t one ).
14 S CANNER O PERATION Visual Indicators The MS1890 has three LED indic ators (yellow, white and blue) located on the top of the scanner. When the scanner is on, the flashing or stationary activity of the LEDs indicates the status of the current scan and the scanner.
15 S CANNER O PERATION Failure Modes Long Razzberry Tone – During Power Up Failed to initialize or configure the sc anner. If the scanner does not respond after reprogramming, return the scanner for repair.
16 S CANNER O PERATION Depth of Field by Minimum Bar Code Element Width M INIMUM B AR C ODE E LEMENT W IDTH 1D PDF A B C D E F G mm .132 .19 .254 .33 .533 .254 .381 mils 5.2 7.5 10.4 13 21 10 15.9 Figure 12. Depth of Field by Minimum Bar Code E lement Width Specifications are subjec t to change without notice.
17 S CANNER O PERATION IR Activation Range The MS1890 has a built in obj ect detection sensor that instantly turns on the scanner when an object is presented with in the scanner’s IR activatio n Area. Figure 13. IR Activation Area Specifications are subjec t to change without notice .
18 T ROUBLESHOOTING G UIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-Me tro or 1- 800-436-3876 to pres erve the limited warranty terms. All Interfaces MS1890 Series Troubleshooting Gui de Symptoms Possible Causes Solution No power is being supplied to the scanner.
19 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The unit powers up, but does not beep when bar code is scanned. The beeper is disabled and no tone is selected. Enable the beeper and select a tone. The unit powers up, but does not scan and/or beep.
20 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The print quality of the bar code is suspect. Check print mode. The type of printer could be the problem. Change print settings (i.e. change to econo mode or high speed) . The aspect ratio of the bar code is out of tolerance.
21 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The unit is transmitting each character twi ce. The configuration is not set correctly. Increase interscan code delay setting. Adjust whether the F0 break is transmitted. It may be necessary to try this in both settings.
22 D ESIGN S PECIFICATIONS MS1890 D ESIGN S PECIFICATIONS O PERATIONAL Light Source: LED 645 nm Pulse Duration: 1 ms to 8 ms Maximum Output of an Osram LED: Maximum 85 mA emits 3,120 mlm Depth of Scan Field: 0 mm – 300 mm (0" – 11.81") for 0.
23 D ESIGN S PECIFICATIONS MS1890 D ESIGN S PECIFICATIONS E LECTRICAL Input Voltage: 5.0VDC ± 0.25V Peak = 2 W (Typical) Operating = 1.65 W (Typical) Power: Idle / Standby = 800 mW (Typical) Peak = 400 mA (Typical) Operation = 330 mA (Typical) Current: Idle / Standby = 160 mA (Typical) DC Transformer: Class 2; 5.
24 A PPLICATIONS AND P ROTOCOLS The model number on each scann er includes the scanner number a nd factory default communications proto col. S CANNER V ERSION I DENTIFIER C OMMUNICATION P ROTOCOL ( S .
25 D EFAULT S ETTINGS – C OMMUNICATION P ARAMETER S Many functions of the scanner can be configu red or enabled/disa bled. The scanner is shipped from the factor y c onfigured to a set of default conditions. The default parameter of the scanner has an asterisk (*) in the charts on the following pages.
26 D EFAULT S ETTINGS – C OMMUNICATION P ARAMETER S PARAMETER DEFAULT RS232 IBM 46XX KBW USB MSI-Plessy 10/10 Check Digit 9 9 9 9 MSI- Pless y Mod 10 Ch eck D igit * 9 9 9 9 Paraf Support ITF 9 9 9 .
27 D EFAULT S ETTINGS – C OMMUNICATION P ARAMETER S PARAMETER DEFAULT RS232 IBM 46XX KBW USB Transmit UPC-A Item ID# * 9 9 9 9 Transmit Codabar Start/Stop C haracters 9 9 9 9 CLSI Editing (Enabl e) .
28 D EFAULT S ETTINGS – C OMMUNICATION P ARAMETER S PARAMETER DEFAULT RS232 IBM 46XX KBW USB XON/XOFF Handshaking 9 ACK/NAK 9 Two Digit Supplements 9 9 9 9 Five Digit Supplements 9 9 9 9 Bookland 9 .
29 C ONFIGURATION M ODES The MS1890 Series has three modes of confi guration. • Bar Codes The MS1890 can be configur ed by scanning the bar cod es included in the Metrologic Single-Line Co nfiguration Guide ( MLPN 00-02544) or the Area Imaging Bar Code Supplemental Co nfiguration Guide ( MLPN 00-02281).
30 U PGRADING THE F LASH ROM F IRMWARE The MetroSet2 program is a functional c omponent of Metrologic’s ne w line of Flash- based scanners. T his program allows the user of a Metrologic sca nner to quickly upgrade to a ne w or custom version of firmware.
31 S CANNER AND C ABLE T ERMINATIONS Scanner Pinout Connections MS1890-14, RS232 Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RTS Output 5 CTS Input 6 DTR Input 7 Reserved 8 Reserved 9 +5VDC The MS1890 scanner interfaces terminate to a 10-pin, RJ45 Female Socket.
32 S CANNER AND C ABLE T ERMINATIONS Scanner Pinout Connections MS1890-38, Low Speed USB Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RTS Output 5 CTS Input 6 USB D+ 7 V USB 8.
33 S CANNER AND C ABLE T ERMINATIONS Cable Connector Configurations (Host End) RS232 PowerLink Cable MLPN 53-53700 x -3 Pin Function 1 Shield Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 DTR.
34 S CANNER AND C ABLE T ERMINATIONS Cable Connector Configurations (Host End) Keyboard Wedge Po werLink Cable MLPN 53-53702x-3 Pin Function 1 Keyboard Clock 2 Keyboard Data 3 No Connect 4 Power Groun.
35 L IMITED W ARRANTY The MS1890 series scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A . facility. The MS18 90 series scanners have a thre e (3) y ear limited warranty from the date of manufacture.
36 R EGULATORY C OMPLIANCE Safety ITE Equipment IEC 60950-1, EN 60950-1 LED Class 1 LED Product: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2 Caution Use of controls or adj ustments or performan ce of procedures other than tho se specified herei n may result in h azardous radi ation exposur e.
37 R EGULATORY C OMPLIANCE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 Changes or modifications not expressly approved by the party respo nsible for compliance could void the user’s authority to operate the equipment.
38 R EGULATORY C OMPLIANCE EMC Changes or modifications not expressly approved by the party respo nsible for compliance could void the user’s authority to operate the equipment. Class B Devices The following is applicable w hen the scanner cable is les s than 3 meters (9.
39 P ATENTS This METROLOGIC product may be covere d by, but not limited to, one or more of the following U.S. Patents: U.S. Patent No.; 7,086,595; 7,128,266 No license right or sublicense is grante d,.
40 I NDEX A AC ................................. 2, 7–11, 23 Accessori es ................................... 2 Adapter .................................... 2, 34 Apertu re......................................... 4 Audible Indica tor ..............
41 I NDEX Light Lev els ................................. 23 Light S ource ................................ 22 M Maintenanc e .................................. 6 Meteor ......................................... 30 MetroSelect ..................... 13, 24, 29 MetroSet 2 .
42.
.
June 2007 Printed in the USA 00 - 02293 A.
Een belangrijk punt na aankoop van elk apparaat Metrologic Instruments MS1890 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Metrologic Instruments MS1890 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Metrologic Instruments MS1890 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Metrologic Instruments MS1890 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Metrologic Instruments MS1890 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Metrologic Instruments MS1890 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Metrologic Instruments MS1890 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Metrologic Instruments MS1890 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.