MS9530 Series Voyager® RF Single Line Hand-Held RF Bar Code Scanner Installation and User’s Guide PRELIMINARY MS9530 Voyager RF Printed: September 2002 Version: 1.
Table of Contents Voyager RF Scanne r – Over view ............................................................ 3 Base Stat ion.............................................................................................. 4 Unpacking List............
Product Overview The MS9530 Series Voyager RF is a wireless single line hand-held scanner with one bi-directional RF channel radio which provides about 20-30 meters portability. It has got a battery pack which can be removed from the unit to be charged through a Wall-Power supply in about 110 min.
BASE STATION The Base Station is a interface decoder to which the Voyager is connected via a virtual RS232 port. Its func tion is to receive RF data from Voyager RF and transmit it to the Host.
UNPACKING LIST The kit is packed accordi ng to its functionality: Transmitter: • Voyager RF: Reader + Battery Pack • Wall-Power Supply for Battery Pack charging • Voyager RF Configuration Manual • Voyager RF installation and User guide Base Station: • Base Station • Base Station Manual • For Wedge interface: 1.
CONNECTING THE BASE STATION TO THE HOST WEDGE INTERFACE 1. Turn off the Host system 2. Connect the cable Y-XX between the keyboard and Host 3. When Power supply required (it is recommended all the times for better RF transmissions), check that the voltage matches the AC outlet and then connect 4.
LINKING THE VOYAGER RF TO THE BASE STATION This section explains how to link the Vo yager RF to the Base Station. It is supposed that the software is already loaded into the unit and that the Base Station is configured with its own serial number. • Power ON the Base Station • Insert Battery Pack and press CodeGate button to power ON the unit.
• Read Fix Serial RF Number barcode to load Base Station's serial number into the Voyager. • Read Base Station Serial Number barcode. (located on the Base Station). • Read Enter/Exit Configuration Mode barcode. • After reading this barcode the Voyager will try to link the Base Station.
FIXING VOYAGER RF ID NUMBERS This section explains how to fix an Identifier number to each Voyager RF. Basically, each Base Station can work with up to 5 VoyagerRF’s at the same time. To enable this facility, an Identif ier Number (ID) mu st be configured to each Voyager RF.
The system is ready to work. Please note again, that each time a Voyager RF is activated, it indicates its ID number just before linking with Base Station with steady RED and GREEN LED’s whilst the YELLOW LED flashes an appropriate number of times in relation to its ID number.
BASE STATION TESTING BARCODE The Base Station will accept all data fr om Voyager RF where the Base Serial Number is “0000000000”. Use this Test Barcode as Base Serial Number when programming the Voyager RF Serial Number to fix t he Voyager RF in test Mode.
BATTERY PACK In order to charge the Batte ry Pack, there is no need to use a cradle. It can be re-charged when disconnected from the sca nner with the Voyager RF 5V, 1.5A Wall Power Supply. The Battery Pack can’t be recharged while inserted into the Voyager.
Standby mode will discharge the battery pac k in around 5 days. The number of readings will naturally decreas e as the standby time incr eases. To avoid having low battery messages appearing, it is recommended that the battery pack is disconnected from the sc anner when not in use over an extended period of time.
VISUAL INDICATORS The scanner has RED and GREEN LED’s. When the scanner is on, these visual indicators show the st ate of the scanner functionality. Start Up Sequence From Stand-by, once the user presses Co deGate button, the scanner goes into start-up mode.
Low Battery Message When the battery starts to loose its c harge, the scanner detects it and makes a Razzberry sound every time a new r eading is performed. The YELLOW, RED and GREEN LED’s will also flash alternatively. However, the Voyager RF will continue to operate.
PROGRAMING MODES Voyager RF can be programmed vi a Barcodes. Use Metrologic’s MetroSelect Single Line Configuration Guide to configure the unit. This configuration guide is common to all Voyagers.
MetroSet It is possible to download/upload se ttings from MetroSet 2 (PC based software) to each Voyager RF by radio. In order to do that, read t he MetroSet RF barcode with the Voyager RF that you want to work with and follow MetroSet RF instructions.
SOFTWARE VERSION It is possible to find out the software of Voyager RF as well as the Base Station to which the unit is linked with. Scanning the following barcode, the Base Station will transmit the actual software revision with the following format: MI9530 BASE STATION: #50200, MA RCH 2002.
EML EML Handshake is a defined data formatting handshake that allows the Voyager RF to send and receive data from the Host System through the Base Station.
MS9530 Voyager RF Printed: September 2002 Version: 1.1 Status: Approved 20 SPECIFICATIONS RF LINK SPECIFICATIONS Frequencies: 434 MHz Bandwidth: 2 x 75 kHz Modulation: FM RF Protocol: Two way data transmission, One channel. 39062.5 Baud speed. Output Power Voyager RF: <10 mw Output Power Base Station: 6 mw Operating Range: Up to 30 Mts.
Een belangrijk punt na aankoop van elk apparaat Metrologic Instruments MS9530 Series (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Metrologic Instruments MS9530 Series heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Metrologic Instruments MS9530 Series vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Metrologic Instruments MS9530 Series leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Metrologic Instruments MS9530 Series krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Metrologic Instruments MS9530 Series bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Metrologic Instruments MS9530 Series kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Metrologic Instruments MS9530 Series . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.