METROLOGIC ® INSTRUMENTS, INC. TECH 7 ® Laser Bar Code Projection Scanner Inst allation and User ’ s Guide.
Copyright © 2006 by Metrologic Instruments, Inc. All rights reserved. No p art of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer , who may quote brief pas- sages in a review , or provided for in the Copyright Act of 1976.
ii T able of Content s Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Unpacking List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Scanner Installation . . . . . . . .
.
1 Introduction Metrologic's TECH 7 ® laser bar code projection scanner is encased in an NEMA-12 steel case. The case construction enables the scanner to operate in harsh surroundings, especially industrial environments. W ater-resist ant, shock-resistant, and rugged, the TECH 7 is also fast, aggressive and reliable.
Scanner Inst allation T o maint ain compliance with applicable standards, all circuit s con- nected to the scanner must meet the requirements for SEL V (Safety Extra Low V oltage) according to EN 60950. T o avoid potential prob- lems, do not power up the scanner until the communication cable is secured to the host.
Configuration to the Host System The scanner is shipped from the factory programmed to a set of default conditions noted in the ScanSelect™ Scanner Programming Guide by an asterisk that appears before the brief definition located next to the bar code.
St and Installation With the Metrologic stand (Part #45475), the scanner can be posi- tioned in one of two directions. The two orient ation choices are vertical or horizontal. (Refer to Figure 1) T o inst all this stand, use the four 6-32 x ½ inch machine screws and two #10 pan head wood screws.
Back Plate Inst allation With the Metrologic back plate (Part #45473), position the scanner in one of two directions. The two orientation choices are vertical or horizontal. (Refer to Figure 4). T o use this stand, use the four 6-32 x ½ inch machine screws and four wood screws to attach the unit to the back plate and work surface.
Part s of Scanner 1 Green and Red LEDs When the green LED is on, this indicates that the unit is receiving power and the laser is on. When the red LED flashes on, the scanner has read a bar code successfully . When the red light turns off, communication to the host is complete.
7 Visual Indicators There is a red and green LED at the top of the scanner . When the scanner is on, the flashing or stationary activity of the LEDs indicates the status of the scan and scanner . Steady Green When the laser is on, the green LED is also on.
Signaux Optiques Sur la partie supérieure du scanner se trouvent une diode LED rouge et une diode LED verte. Quand le scanner est sous tension, les diodes rouge et verte clignotantes ou allumées vous informent sur l'état du scanner .
Optische Anzeigen Auf dem Scanner befinden sich eine rote und eine grüne Leuchtdiode. Bei eingeschaltetem Scanner geben Ihnen die blinkenden bzw . feststehenden Leuchtdiodenanzeigen Aufschluß über den Abtast-und Scannerst atus.
Segnali Ottici Sullo scanner si trovano due diodi luminosi: uno rosso e uno verde. Quando lo scanner è inserito, i diodi luminosi, che possono o essere accesi in continuazione o lampeggiare, Vi informano sullo st ato della scansione e dell'apparecchio.
11 Labels There is one label located inside the window of the scanner noting that this device is a CDRH Class IIa laser product and IEC 825 LASERKLASSE 1. Also, on the scanner is a label located on the back of the unit. This label cont ains information such as the model number , date of manufacture, serial number , and approvals.
Depth of Scan Field for the MS770 Scanner The depth of field for the scanner is 76mm to 254mm (3.00” - 10.00”) from the laser output window . Pass the symbol through the scan area in order for the scanner to recognize the bar code. (Refer to Figure 7) Figure 7: MS770 Scanner , Front View 12 76 mm [3.
Depth of Scan Field for the MS775 Scanner The depth of field for the scanner is 76mm to 254mm (3.00” - 10.00”) from the laser output window . Pass the symbol through the scan area in order for the scanner to recognize the bar code. (Refer to Figure 8) Figure 8: MS775 Scanner , Front View 13 229 mm [9.
Maintenance Smudges and dirt can interfere with the proper scanning of a bar code. Therefore, the output window will need occasional cleaning. 1. S pray glass cleaner onto lint free, nonabrasive cleaning cloth.
Appendix A S pecifications Application: Industrial Projection Scanner Light Source: V isible Laser Diode 650 ± 5 nm or 670 ± 5 nm CDRH: CLASS IIa laser product Certifications: CE, UL listed for the US and CUL for Canada EMC: EN 60825: Class 1 EMI: FCC, ICES-003 & EN 55022 Class A Mechanical Dimensions: 184 mm(L) x 186 mm (W) x 78 mm (D) [7.
Appendix A (Continued) Operational Depth of Scan Field: 76mm to 254 mm (3 in to 10 in) Scan S peed: Model 770: 2000 scan lines per second Model 775: 1200 scan lines per second Scan Pattern: Model 770:.
17 Appendix B Pin Assignment s V ersion "1" Pin Assignment s for RS-232, OCIA, and Bi-direc- tional RS-232 Each TECH 7 scanner has a 19-pin male Mil spec connector that is located on the side of the unit. T o connect the scanner to the host device, use a communication cable with a female Mil spec connector .
Appendix B (Continued) V ersion "15" Pin Assignment s for Light Pen Emulation Each TECH 7 scanner has a 19-pin male Mil spec connector that is located on the side of the unit. T o connect the scanner to the host device, use a communication cable with a female Mil spec connector .
Appendix C W arranty and Disclaimer Limited W arranty The T ech 7 scanners are manufactured by Metrologic at its Blackwood, New Jersey , U.S.A. facility .
Appendix D Notices This equipment has been tested and found to comply with limits for a Class A digit al device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Appendix D (Continued) European St andard Funkstöreigenschaf ten nach EN 55022:1998 St andard Europeo 21 W arning This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Appendix E Patent s “Patent Information This METROLOGIC product may be covered by one or more of the following U.S. Patents: U.S. Patent No. 4,360,798; 4,369,361; 4,387,297; 4,460,120; 4,496,831; 4,.
A AC 2 Applications 1, 14, 15 ASIC 1 Atrium option 6 Autodiscriminate 1, 16 B Back Plate 1, 5, 15 Bidirectional RS-232 14, 17 C Cable 2, 6, 17, 18 communication 1, 6 scanner link 2 Caution 2, 21 Compl.
S Scan pattern 1, 16 Scan S peed 16 ScanSelect 3 ScanSet® 3 Service Center 7 S pecifications 15 S tand 1, 4, 15 V Visual Indicators 7, 8, 9, 16 V oltage 15 W W arning 21 W arranty 19 Window 6, 1 1, 1.
.
.
.
March 2006 Printed in the USA.
Een belangrijk punt na aankoop van elk apparaat Metrologic Instruments TECH 7 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Metrologic Instruments TECH 7 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Metrologic Instruments TECH 7 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Metrologic Instruments TECH 7 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Metrologic Instruments TECH 7 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Metrologic Instruments TECH 7 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Metrologic Instruments TECH 7 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Metrologic Instruments TECH 7 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.