Gebruiksaanwijzing /service van het product HM-1S van de fabrikant Meyer Sound
Ga naar pagina of 18
Patents Pending Operating Instructions HM-1S Self-Powered S tudio Monitor Copyright © 1998 Meyer Sound Laboratories, Inc. All rights reserved Part # 05.
2 Introduction .......................................................... 3 Power Requirements ............................................ 3 Power Cable Requirements .................................. 5 Audio Input ...................................
3 Introduction The Meyer HM-1S S tudio Monitor is a compact, full- range, self-powered reference monitor that employs a concentric tweeter mounting structure to achieve true point-source performance.
4 Power Supplies for Larger Systems If an installation includes more than 10 speakers, or requires several speakers to operate from a single 48 V line, a single, high-output power supply should be considered. The following sections provide current and voltage specifications for the HM-1S s power requirements.
5 audio interruption. In the third, and preferable case, supplies that feature voltage foldback allow brief periods of current-limit without audio interruption; for this reason, we recommend using such supplies. The HM-1S does not require tight voltage regulation and operates down to 35 V although peak SPL values are reduced.
6 HM-1S Speaker Cable The following drawings and procedures are provided as an aid in the event that the speaker cable used to connect the HM-1S to the HM-1S Subwoofer needs to be repaired or extended.
7 HM-1S to HM-1S Subwoofer Cable Connector Assembly Procedure Cable Boot Cord Connector Cable Clamp Housing Contact Pins Coupling Ring Step 1: Feed the end of the cable through the boot, cable clamp housing, and coupling ring in the order and position shown.
8 Subwoofer Performance V erification There are two methods of verifying that the phase relationship between the HM-1S and its subwoofer. One method is free field, the other is a ground plane measurement in half space.
9 This represents a typical response of the HM-1S in free-field environment, on axis at 1 meter. This measurement was performed in the large anechoic chamber at MSLI. Connect the subwoofer and measure the combined response of the system. HM-1S on axis at 1 meter , free field.
10 This represents a typical response of the HM-1S and subwoofer, in phase, in a free field environment on axis at 1 meter. This measurement was performed in the large anechoic chamber at MSLI. This response indicates a complementary phase relationship between the HM-1S and subwoofer.
11 If the subwoofer is out of phase, the combined response will have a significant loss of energy compared to the overall response at around 82 Hz as illustrated below: HM-1S with out-of-phase subwoofer on axis at 1 meter , free field.
12 This represents a typical response of the HM-1S and subwoofer out-of-phase phase, in a free field environment on- axis at 1 meter. This measurement was performed in the large anechoic chamber at MSLI. If your system response indicates a phase reversal please contact Meyer Sound Technical Support for assistance.
13 This represents a typical ground-plane response of the HM-1S, on-axis at 1 meter. Keep in mind that any surface close to the test space can create reflections which will change the response of the speaker. Connect the subwoofer to the HM-1S and measure the combined response of the system.
14 HM-1S with in-phase Subwoofer on axis at 1 meter , ground plane. This represents a typical ground-plane response of the HM-1S and subwoofer, in phase, at 1 meter. This response indicates a complementary phase relationship between the HM-1S and subwoofer.
15 HM-1S with out-of-phase Subwoofer on axis at 1 meter , ground plane. If the subwoofer is out of phase the combined response will have a significant loss of energy compared to the overall response a.
16 Cooling and Fan Installation The HM-1S depends on natural convection to cool the heatsinks that absorb heat from the amplifiers and radiate the heat into the surrounding air space. Natural convection requires free air in back of, and underneath the HM-1S to allow air to flow up over the heatsinks.
17 T o reduce the risk of electric shock, disconnect the loud- speaker from the AC adapter before installing audio cable. Reconnect the adapter only after making all signal con- nections. Connect the AC adapter to a two-pole, three wire grounding mains receptacle.
18 Meyer Sound Laboratories, Inc. 2832 San Pablo Avenue Berkeley, California 94702 Telephone: 510 - 486 - 1166 FAX: 510 - 486 - 8356 E-mail: techsupport@meyersound.
Een belangrijk punt na aankoop van elk apparaat Meyer Sound HM-1S (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Meyer Sound HM-1S heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Meyer Sound HM-1S vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Meyer Sound HM-1S leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Meyer Sound HM-1S krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Meyer Sound HM-1S bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Meyer Sound HM-1S kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Meyer Sound HM-1S . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.