Keep these important operating instructions. Check www .meyerso und.com for updates. OPERATING INSTRUCTIONS ULTRASERIES UP-4XP™ UltraCompact Loudspeaker .
ii DECLARATION OF CONFORMITY ACCORDIN G TO ISO/IEC GUIDE 22 AND EN 45014 © 2011 Meyer Sound. All rights reserved. UP-4XP Operating Instructions, PN 05.
iii SYMBOLS USED These symbols indicate important safety or operating featu res in this booklet and on the chassis: IMPORTANT SAFETY INSTRUCTIONS 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all inst ructions.
iv SAFETY SUMMARY English ■ T o reduce the risk of electric shock, dis- connect the loudspeaker from the AC mains before installing audio cable. Reconnect the power cord only after making all signal connections. ■ Connect the loudspeaker to a tw o-pole, three-wir e grounding mains receptacle.
v CONTENTS Chapter 1: Introduction 7 How to Use This Manual 7 UP-4XP UltraCompact Loudspeaker 7 Chapter 2: UP-4XP Loudspeaker 11 UP-4XP Input Connector 11 UP-4XP LED 12 UP-4XP Current Draw and Cable R.
CONTENTS vi.
7 CHAPTER 1: INTR ODUCTION HOW TO USE THIS MANUAL Make sure to r ead these operating instructions in their entirety befor e configuring a loudspeaker system with UP-4XPs.
CHAPTER 1: INTRODUCTION 8 The UP-4XP is available with either a Phoenix™ 5-pin male or sealed SwitchCraft ® EN3™ male connector for r eceiving balanced audio and DC power . Powering the unit from an external source eliminates the need for wiring conduits while still preserving the advantages of self-power ed systems.
UP-4XP OPERATING INSTRUCTIONS 9 MY A-UP4 Cradle-Style Y oke MUB-UP4 U-Bracket in Wall Mount Configuration UP-4XP with MSA-UPM Pole-Mount Adapter MUB-UP4 U-Bracket in Ceiling Mount Configura tion.
CHAPTER 1: INTRODUCTION 10.
11 CHAPTER 2: UP-4XP LOUDSPEAKER The UP-4XP is powered by an ext er nal 48 V DC power sup- ply , eliminating the need for wiring conduits while still pr e- serving the advantages of self-power ed loudspeaker systems.
CHAPTER 2: UP-4XP LOUDSPEAKER 12 CAUTION: When wiring UP-4XP loudspeaker cables, it is extremely important that each pin be wired corr ectly . Make sure the 48 V DC fro m the external power supply is .
UP-4XP OPERATING INSTRUCTIONS 13 Clipping (Red) The UP-4XP turns red when the loudspeaker’ s input stage clips, causing the amplifier to overload. When the LED is red, the sour ce level should be reduced.
CHAPTER 2: UP-4XP LOUDSPEAKER 14 WIRING UP-4XP LOUDSPEAKER CABLES WITH BELDEN 1502 CABLE (OR EQUIVALENT) The most convenient method of wiring UP-4XP loudspeaker cables is with a multiconductor cable such as Belden 1502, which has dedicated conductors for DC power and bal- anced audio in a single jacket.
15 CHAPTER 3: POWERING UP-4XP LOUDSPEAKERS CONNECTING UP-4XP LOUDSPEAKERS TO THE MPS-488HP EXTER NAL POWER SUPPLY UP-4XP loudspeakers requir e a Meyer Sound 48 V DC external power supply , such the MPS-488HP.
CHAPTER 3: POWERING UP-4XP LOUDSPEAKERS 16 ■ When connecting UP-4XP loudspeakers equipped with EN3 connectors to the MPS-488HPe power supply , use EN3 5-pin male to EN3 5-pin female cables.
UP-4XP OPERATING INSTRUCTIONS 17 CONNECTING UP-4XP LOUDSPEAKERS TO THE MPS-488 EXTERNAL POWER SUPPLY The original MPS-488 was designed for use with the MM-4XP miniature loudspeaker .
CHAPTER 3: POWERING UP-4XP LOUDSPEAKERS 18.
19 CHAPTER 4: QUICKFLY RIGGING The UP-4XP includes top and bottom mounting plates with 3/8-16 or metric M10 threaded nuts. QuickFly mounting options include the MUB-UP4 U-bracket, MY A-UP4 cradle- style yoke, and MSA-UPM pole-mount adaptor .
CHAPTER 4: QUICKFLY RIGGING 20 TIP: Meyer Sound of fers two kits for mounting the UP-4XP on top of the UMS-1P subwoofer . The MPS-UMS pole mount kit (PN 40.086.014.02) includes a 43-inch (1090 mm), 3/8-inch (35 mm) diameter pole assembly . The MPK-UMS pole mount kit (PN 40.
UP-4XP OPERATING INSTRUCTIONS 21 MUB-UP4 U-BRACKET The MUB-UP4 U-bracket mounts the UP-4 XP on walls, ceil- ings, and floors. The MUB-UP4 is available in two kits: one with 3/8-16 knobs (PN 40.201.069.01), and one with M10 knobs (PN 40.201.069.02). T o install the U-bracket, secure the loudspeaker to the bracket with the included knobs and washers.
CHAPTER 4: QUICKFLY RIGGING 22.
23 APPENDIX A: UP-4XP ACCESSORIES UP-4XP ACCESSORIES The following UP-4XP accessories are a vailable from Meyer Sound. NOTE: The MPS-488HP external power supply replaces the MPS-488 model, which was originally designed for use with MM-4XP loudspeakers.
APPENDIX A: UP-4XP ACCESSORIES 24 PHOENIX AND EN3 LOUDSPEAKER CABLES The following Phoenix and EN3 cables ar e available from Meyer Sound and can be used to connect UP-4XPs to MPS-488HPs. NOTE: Bulk cables use Belden 1502R (r egular) or Belden 1502P (plenum) cable.
25 APPENDIX B: PHOENIX AND EN3 CABLE ASSEMBLY CAUTION: When wiring UP-4XP loudspeaker cables, it is ext remely important that each pin be wired correctly .
APPENDIX B: PHOENIX AND EN3 CABLE ASSEMBLY 26 2. If the cable has not been stripped, strip the outer shielding 1 inch and then strip the black, red, blue, and white wir es .275 inch. 3. Solder the five exposed conductors to the five pins on the EN3 cor d connector using the following wiring scheme.
UP-4XP OPERATING INSTRUCTIONS 27 5. Repeat the previous steps to attach the EN3 5-pin female connector to the other end of the cable. ASSEMBLING EN3-TO-PHOENIX LOUDSPEAKER CABLES When connecting UP-4XP loudspeakers equipped with EN3 co nnectors to the MPS-488HPp power supply , you need an EN3 5-pin female to Phoenix 5-pin female cable.
APPENDIX B: PHOENIX AND EN3 CABLE ASSEMBLY 28 2. Insert the five exposed conductors into the five cable holes in the Phoenix connector using th e following wiring scheme. 3. Secure the conductors by tightening t he five screws in the Phoenix conductor .
UP-4XP OPERATING INSTRUCTIONS 29 6. Solder the five exposed conductors to the five pins on the EN3 cor d connector using the following wiring scheme. 7. Reassemble the EN3 5-pin female connector: ■ Align the coupling ring’ s side notches with the cord connector’ s side notches and slide the couple ring onto the cor d connector .
APPENDIX B: PHOENIX AND EN3 CABLE ASSEMBLY 30 2. Insert the five exposed conductors, fr om one end of the cable, into the five c able holes in one of the Phoenix connectors. Use the following wiring scheme. 3. Secure the conductors by tightening t he five screws in the Phoenix connector .
31 APPENDIX C: W EATHER PR OTECTION UP-4XP LOUDSPEAKERS WITH W EATHER PR OTECTION A weather -protected version of the UP-4XP with a sealed EN3 connector is available for fixed, outdoor installations.
APPENDIX C: WEATHER PROTECTION 32.
33 APPENDIX D: UP-4XP SPECIFICATIONS UP-4XP Specif ications ACOUSTICA L Operating Frequency Range 66 Hz – 18 kHz Note: Rec ommended maximum operating frequency rang e. Response depends on loadi ng condi- tions and room acousti cs. Frequency Response 72 Hz – 17.
APPENDIX D: UP-4XP SPECIFICATIONS 34 UP-4XP COMPLIANCE Output Power 500 W total for all three channels Note: Wattage rating ba sed on the ma ximum unclipped burst sine-wave rms vol tage the amplifier will produce into the nominal load impedance. THD, IM TIM <.
UP-4XP OPERATING INSTRUCTIONS 35 UP-4XP DIMENSIONS UP-4XP Dimensions 13.84 [352 mm] 5.54 [141 mm] 5.04 [128 mm] 6.50 [165 mm] 5.25 [133 mm] 2.60 [66 mm] UP-4XP with MUB-UP4 U-Bracket Dimensions 5.25 [133 mm] 13.84 [352 mm] 16.52 [420 mm] 6.86 [174 mm] 5.
APPENDIX D: UP-4XP SPECIFICATIONS 36 MY A-UP4 Mounting Y oke Dimensions 16.64 [423 mm] 10.00 [254 mm] Ø0.53 [Ø13 mm] 6.62 [168 mm] 16.33 [415 mm] 8.63 [219 mm] 14.
.
.
.
Meyer Sound Labo ratories In c. 2832 San Pablo Avenue Berkeley, CA 94702 www.meyersound.com T: +1 510 486.1166 F: +1 510 486.8356 © 2011 Meyer Sound.
Een belangrijk punt na aankoop van elk apparaat Meyer Sound UP-4XP (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Meyer Sound UP-4XP heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Meyer Sound UP-4XP vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Meyer Sound UP-4XP leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Meyer Sound UP-4XP krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Meyer Sound UP-4XP bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Meyer Sound UP-4XP kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Meyer Sound UP-4XP . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.