Gebruiksaanwijzing /service van het product 456 CC van de fabrikant Miller Electric
Ga naar pagina of 44
OM-203 034R 2008 − 11 Processes MIG (GMA W) W elding With Optional Equipment: Pulsed MIG (GMAW -P) XMT 456 CC/CV: Multiprocess W elding Description Invision 456P: Invision 456P: XMT 456 CC/CV: R Invision 456P And X M T 4 5 6 C C / C V (400 V olt Models) R File: MIG (GMA W) V isit our website at www.
Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual specification sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .
T ABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
OM-203 034 Page 1 SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING som _2007 − 04 7 Protect yourself and others from injury — read and follow these precautions. 1-1. Symbol Usage DANGER! − Indicates a hazardous situation which, if not avoided, will result in death or serious injury .
OM-203 034 Page 2 W elding produces fumes and gases. Breathing these fumes and gases can be hazardous to your health. FUMES AND GASES can be hazardous. D Keep your head out of the fumes. Do not breathe the fumes. D If inside, ventilate the area and/or use local forced ventilation at the arc to remove welding fumes and gases.
OM-203 034 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring − be sure power supply system is properly sized, rated, and protected to handle this unit.
OM-203 034 Page 4 1-4. California Proposition 65 W arnings W elding or cutting equipment produces fumes or gases which contain chemicals known to the State of California to cause birth defects and, in some cases, cancer. (California Health & Safety Code Section 25249.
OM-203 034 Page 5 SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE A V ANT UTILISA TION fre_som_2007 − 04 7 Se protéger et protéger les autres contre le risque de blessure — lire et respecter ces consignes.
OM-203 034 Page 6 Il reste une TENSION DC NON NÉGLIGEABLE dans les sources de soudage onduleur quand on a coupé l’alimentation. D Arrêter les convertisseurs, débrancher le courant électrique et décharger les condensateurs d’alimentation selon les instructions indiquées dans la partie Entretien avant de toucher les pièces.
OM-203 034 Page 7 LES ACCUMULA TIONS DE GAZ risquent de provoquer des blessures ou même la mort. D Fermer l’alimentation du gaz protecteur en cas de non-utilisation. D V eiller toujours à bien aérer les espaces confi- nés ou se servir d’un respirateur d’adduction d’air homologué.
OM-203 034 Page 8 LES FILS DE SOUDAGE peuvent provoquer des blessures. D Ne pas appuyer sur la gâchette avant d’en avoir reçu l’instruction. D Ne pas diriger le pistolet vers soi, d’autres per- sonnes ou toute pièce mécanique en enga- geant le fil de soudage.
OM-203 034 Page 9 2-5. P ri nc ipa le s no rm es d e sé cu ri té Safety i n W elding, Cutting, and Allied Processes, ANSI Standard Z49.1, de Global Engineering Documents (téléphone : 1-877-413-5184, site Internet : www .
OM-203 034 Page 10.
OM-203 034 Page 1 1 SECTION 3 − DEFINITIONS 3-1. Manufacturer ’ s W arning Label Definitions W arning! Watch Out! There are possible hazards as shown by the symbols. 1 Electric shock from welding electrode or wiring can kill. 1.1 Wear dry insulating gloves.
OM-203 034 Page 12 > 60 s V S-179 190-A V V 1 Warning! W atch Out! There are possible hazards as shown by the symbols. 2 Electric shock from wiring can kill. 3 Disconnect input plug or power before working on machine. 4 Hazardous voltage remains on input capacitors after power is turned off.
OM-203 034 Page 13 3-2. Symbols And Definitions A Amperage Panel Alternating Current (AC) V V oltage Output Circuit Breaker Remote On Of f Gas Tungsten Arc W elding Negative V oltage Input Direct Curr.
OM-203 034 Page 14 SECTION 4 − INST ALLA TION . This manual contains information on CC and CC/CV units. Differences between models are noted throughout this manual.
OM-203 034 Page 15 4-3. V olt-Ampere Curves V olt-ampere curves show mini- mum and maximum voltage and amperage output capabilities of unit. Curves of other settings fall be- tween curves shown. va_curve1 4/95 − SA-181 561 / SA-181 562 CC Modes CV Modes 4-4.
OM-203 034 Page 16 4-5. Selecting A Location loc_2 3/96 - 800 61 1 / 802 260 1 Lifting Forks Use lifting forks to move unit. Extend forks beyond opposite side of unit. 2 Lifting Handles Use handles to lift unit. 3 Hand Cart Use cart or similar device to move unit.
OM-203 034 Page 17 4-7. W eld Output T erminals And Selecting Cable Sizes ! ARC WELDING can cause Electromagnetic Interference. T o reduce possible interference, keep weld cables as short as possible, close together , and down low , such as on the floor .
OM-203 034 Page 18 4-8. Connecting Weld Output Cables 803 778-B ! T urn off power before connecting to weld output terminals. ! Failure to properly connect weld cables may cause excessive heat an d start a fire, or damage your ma- chine.
OM-203 034 Page 19 4-10. 1 15 V olts AC Duplex Receptacle Ref. 801 524-A 1 1 15 V 7 A AC Receptacle Power is shared between duplex receptacle and Remote 14 recep- tacle (see Section 4-9). 2 Circuit Breaker CB1 3 Circuit Breaker CB2 CB 1 protects 1 15 volts ac portion of duplex receptacle and Remote 14 receptacle from overload.
OM-203 034 Page 20 4-12. Connecting Input Power ssb2.4* 1/94 − 801 523-B / 801 946 T ools Needed: 5/16 in Input Filter Board L1 =GND/PE ! T urn Off welding power source, and check voltage on input capacitors according to Section 6-3 before pro- ceeding.
OM-203 034 Page 21 SECTION 5 − OPERA TION 5-1. Front Panel Controls For CV Only Models 1 Power On/Off Switch . The fan motor is thermostatically controlled and only runs when cooling is needed.
OM-203 034 Page 22 5-3. Meter Functions For CV Only Models . The meters display the actual weld output values for approximately three seconds after the arc is broken. Mode Meter Reading At Idle Meter Reading While W elding MIG Preset V olts Blank VA 24.
OM-203 034 Page 23 5-5. Meter Functions For CC/CV Models . The meters display the actual weld output values for approximately three seconds after the arc is broken. Mode Meter Reading At Idle Panel Control (GT AW) Actual V olts (OCV) Preset Amps VA 80.
OM-203 034 Page 24 5-6. Mode Switch Settings For CC/CV Models . Th e SMA W modes provide the Adaptive Hot Start ™ feature, which automatically increases the output amperage at the start of a weld should the start require it. This eliminates electrode sticking at arc start.
OM-203 034 Page 25 5-7. Lift-Arc TIG Procedure For CC/CV Models With Mode switch in the Lift-Arc TIG position, start an arc as follows: 1 TIG Electrode 2 W orkpiece T ouch tungsten electrode to work- piece at weld start point, hold electrode to workpiece for 1-2 seconds , and slowly lift electrode.
OM-203 034 Page 26 SECTION 6 − MAINTENANCE & TROUBLESHOOTING 6-1. Routine Maintenance ! Disconnect power before maintaining. . Maintain more often during severe conditions.
OM-203 034 Page 27 6-3. Removing Case and Measuring Input Capacitor V oltage Turn Of f welding power source, a nd disconnect input power . 1 Outside Handle Screws T o loosen top, remove two outside handle screws from both handles and all side bolts.
OM-203 034 Page 28 6-4. V oltmeter/Ammeter Help Displays . Al l directions are in reference to th e front of the unit. All circuitry referred to is located inside the unit. 1 Help 0 Display Indicates a shorted thermistor R T2 on the left side of the unit.
OM-203 034 Page 29 6-5. T roubleshooting T rouble Remedy No weld output; unit completely inop- erative. Place line disconnect switch in On position (see Section 4-12 ). Check and replace line fuse(s), if necessary , or reset circuit breaker (see Section 4-12 ).
OM-203 034 Page 30 SECTION 7 − ELECTRICAL DIAGRAM Figure 7-1. Circuit Diagram For CV Only Welding Power Source.
OM-203 034 Page 31 239 524-A.
OM-203 034 Page 32 Figure 7-2. Circuit Diagram For CC/CV Welding Power Source.
OM-203 034 Page 33 239 526-A.
OM-203 034 Page 34 SECTION 8 − P ARTS LIST . Hardware is common and not available unless listed. 802 261-E 68 67 57 56 55 52 10 61 60 47 43 36 38 37 36 35 34 30 8 7 6 5 4 66 3 PC2 PC1 4 65 64 63 62 59 58 54 53 51 46 50 49 48 46 45 44 4 42 41 40 39 33 32 31 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 9 2 1 Figure 8-1.
OM-203 034 Page 35 Description Part No. Dia. Mkgs. Item No. Figure 8-1. Complete Assembly Quantity 1 187 234 Cover , T op 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-203 034 Page 36 Description Part No. Dia. Mkgs. Item No. Figure 8-1. Complete Assembly (Continued) Quantity 48 180 732 Boot, Neg Output Stud 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Notes 229895 MA TERIAL THICKNESS GAUGE.
Notes W or k l i ke a P r o ! Pros wel d and cut safel y . R ead t he safety rules at the beginni ng of this manual ..
Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 2008-01 Y our distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours.
PRINTED IN USA © 2008 Miller Electric Mfg. Co. 2008 − 01 Miller Elect ric Mfg. Co. An Illinois T ool W orks Compa ny 1635 West S pencer S treet Applet on, WI 5 4914 US A International He adquarters.
Een belangrijk punt na aankoop van elk apparaat Miller Electric 456 CC (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Miller Electric 456 CC heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Miller Electric 456 CC vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Miller Electric 456 CC leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Miller Electric 456 CC krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Miller Electric 456 CC bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Miller Electric 456 CC kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Miller Electric 456 CC . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.