Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual catalog sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .
T ABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS − READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
T ABLE OF CONTENTS SECTION 7 − OPERA TING WELDING GENERA TOR − CC/CV MODELS 34 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1. Front Panel Controls For CC/CV Models (See Section 7-2) 34 . . . . . . . . . . . . . . . . . . . . . . . .
dec_con1_1 1/02 Declaration of Conformity for European Community (CE) Products This information is provided for units with CE certification (see rating label on unit). NOTE Manufacturer ’ s Name: Miller Electric Mfg. Co. Manufacturer ’ s Address: 1635 W .
dec_con1_sound1 1/02 Declaration of Conformity for European Community (CE) Products This information is provided for units with CE certification (see rating label on unit). NOTE Manufacturer ’ s Name: Miller Electric Mfg. Co. Manufacturer ’ s Address: 1635 W .
OM-4406 Page 1 Return T o T able Of Conte nts SECTION 1 − SAFETY PRECAUTIONS − READ BEFORE USING rom _nd_8/03 W arning: Protect yourself and others from injury — read and follow these precautions.
OM-4406 Page 2 Return T o T able Of C ont ents W elding on closed containers, such as tanks, drums, or pipes, can cause them to blow up. Sparks can fly off from the welding arc. The flying sparks, hot workpiece, and hot equipment can cause fires and burns.
OM-4406 Page 3 Return T o T able Of C ont ents STEAM AND HOT COOLANT can burn. If possible, check coolant level when engine is cold to avoid scalding. Always check coolant level at overflow tank, if pres- ent on unit, instead of radiator (unless told otherwise in maintenance section or engine manual).
OM-4406 Page 4 Return T o T able Of C ont ents READ INSTRUCTIONS. Use only genuine MILLER/Hobart replacement parts. Perform engine and air compressor (if applicable) maintenance and service according to this manual and the engine/air compressor (if applicable) manu- als.
OM-4406 Page 5 Revenez à la table des matières SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE A V ANT UTILISA TION rom_fre 8/03 A vertissement: Protégez vous et les autres des blessures − lisez et suivez ces précautions.
OM-4406 Page 6 Revenez à la table des matières LES ACCUMULA TIONS DE GAZ ris- quent de provoquer des blessures ou même la mort. Fermer l’alimentation du gaz protecteur en cas de non utilisation. V eiller toujours à bien aérer les espaces confinés ou se servir d’un respi- rateur d’adduction d’air homologué.
OM-4406 Page 7 Revenez à la table des matières L ’EXPLOSION DE LA BA TTERIE peut RENDRE A VEUGLE. T oujours porter une protection faciale, des gants en caoutchouc et vêtements de protection lors d’une in- tervention sur la batterie. Arrêter le moteur avant de débrancher ou de brancher les câbles de batterie.
OM-4406 Page 8 Revenez à la table des matières LE SURCHAUFFEMENT peut endom- mager le moteur électrique. Arrêter ou déconnecter l’équipement avant de dé- marrer ou d’arrêter le moteur .
OM-4406 Page 9 Return T o T able Of Contents SECTION 3 − DEFINITIONS 3-1. W arning Label Definitions 3/96 W arning! Watch Out! There are possible hazards as shown by the symbols. Become trained and read the instructions before working on the machine or we l ding.
OM-4406 Page 10 Return T o T able Of C ont ents 3/96 1 Warning! W atch Out! There are possible hazards as shown by the symbols. 2 Do not smoke and keep matches and flames away from battery . 3 Sparks can cause battery gases to explode. Battery explosion can blind and injure.
OM-4406 Page 1 1 Return T o T able Of Contents 3/96 1 Warning! W atch Out! There are possible hazards as shown by the symbols. 2 Hot muf fler and exhaust pipes can cause severe burns. Do not touch hot muf fler or pipes. 1 S-176 230 2 3/96 1 2 4 3 5 6 S-176 104 3/96 1 Warning! W atch Out! There are possible hazards as shown by the symbols.
OM-4406 Page 12 Return T o T able Of C ont ents 1 Warning! W atch Out! There are possible hazards as shown by the symbols. 2 Fire hazard from leaking engine fuel. Fire can result from welding on base at non-designated areas causing a possible fuel leak.
OM-4406 Page 13 Return T o T able Of Cont ent s 3/96 1 Remove unit from shipping crate. Remove Owner’s Manual from unit. Follow instructions to install muf fler . 2 Read Owner ’s Manual. Read labels on unit. 3 Use Diesel Fuel only , and fill fuel tank.
OM-4406 Page 14 Return T o T able Of Contents 3-3. Symbols And Definitions Some symbols are found only on CE products. NOTE Stop Engine Fast (Run, Weld/ Power) Slow (Idle) Start Engine Starting Aid Ba.
OM-4406 Page 15 Return T o T able Of Contents SECTION 4 − SPECIFICA TIONS 4-1. W eld, Power , And Engine Specifications W elding Mode W eld Output Range Rated W elding Output Maximum Open- Circuit V.
OM-4406 Page 16 Return T o T able Of C ont ents 0 20 40 60 80 100 0 100 200 300 400 500 600 700 4-3. V olt-Ampere Curves For CC Models 202 666-A The volt-ampere curve shows the minimum and maximum voltage an d amperage output capabilities of th e welding generator .
OM-4406 Page 17 Return T o T able Of Cont ent s 4-4. V olt-Ampere Curves For CC/CV Models 202 655 / 202 656 / 202 654 The volt-ampere curves show the minimum and maximum voltage an d amperage output capabilities of th e welding generator . Curves of al l other settings fall between the curves shown.
OM-4406 Page 18 Return T o T able Of C ont ents 4-5. Fuel Consumption The curve shows typical fuel use under weld or power loads. 199 032 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 0 50 100 150 200 250 300 350 400 DC WELD AMPERES A T 100% DUTY CYCLE US Gal.
OM-4406 Page 19 Return T o T able Of Cont ent s 4-7. AC Generator Power Curve 193 018 Th e ac power curve shows the gen- erator power in amperes available at the 120 and 240 volt receptacles. 0 50 100 150 200 250 300 0 5 10 15 20 25 30 AC AMPERES IN 240V MODE AC VOL TS 0 25 50 75 100 150 125 0 1 02 03 0 4 05 0 6 0 AC AMPERES IN 120V MODE 4-8.
OM-4406 Page 20 Return T o T able Of C ont ents 4-9. V olt-Ampere Curve For CC/CV Models In AC TIG Mode 207 045 AC output is only available on units equipped with optional Polarity/AC switch. The volt-ampere curve shows the minimum and maximum voltage an d amperage output capabilities of th e welding generator .
OM-4406 Page 21 Return T o T able Of Cont ent s SECTION 5 − INST ALLA TION install3 6/03 − Ref. 800 652 / Ref. 800 477-A / 803 274 Always securely fasten weld- ing generator onto transport vehicle or trailer and comply with all DOT and other applica- ble codes.
OM-4406 Page 22 Return T o T able Of C ont ents 5-2. Using Lifting Eye Ref. 802 31 1 1 Lifting Eye 2 Nut 3 Carriage Bolt Raise lifting eye until it snaps in place.
OM-4406 Page 23 Return T o T able Of Cont ent s 5-3. Mounting Welding Generator T ools Needed: 9/16 in 2 2 3 4 W elding Unit In Place Bolting Unit In Place Do not weld on base. W eld- ing on base can cause fuel tank fire or explosion. Weld only on the four mounting brackets or bolt unit down.
OM-4406 Page 24 Return T o T able Of C ont ents 5-4. Installing Exhaust Pipe 1/2 in T ools Needed: Ref. 802 31 1 / Ref. 201 841 Stop engine and let cool. Point exhaust pipe in desired di- rection but always away from front panel and direction of travel.
OM-4406 Page 25 Return T o T able Of Cont ent s 5-5. Activating The Dry Charge Battery (If Applicable) Remove battery from unit. 1 Eye Protection − Safety Glasses Or Face Shield 2 Rubber Gloves 3 V ent Caps 4 Sulfuric Acid Electrolyte (1.265 Specific Gravity) 5 W ell Fill each cell with electrolyte to bottom of well (maximum).
OM-4406 Page 26 Return T o T able Of C ont ents 5-6. Connecting The Battery 1/2 in − + Connect Negative ( − ) Cable Last. T ools Needed: 802 168-B / Ref.
OM-4406 Page 27 Return T o T able Of Contents 5-7. Engine Prestart Checks Check all engine fluids daily . Engine must be cold and on a level surface. Unit is shipped with 20W break-in oil. Automatic shutdown system stops engine if oil pressure is too low or coolant tempera- ture is too high.
OM-4406 Page 28 Return T o T able Of Contents 5-8. Connecting T o W eld Output T erminals 802 31 1 T ools Needed: 3/4 in 1 2 Stop engine. 1 Positive (+) Weld Output T erminal 2 Negative ( − ) We.
OM-4406 Page 29 Return T o T able Of Contents 5-10. Connecting T o Remote Amperage Adjust Receptacle RC13 On CC Models Ref. 154 862-A / 048 720-K / 802 31 1 1 Remote Amperage Adjust Receptacle RC13 Connect optional remote control to RC13 (see Section 6-3).
OM-4406 Page 30 Return T o T able Of Contents SECTION 6 − OPERA TING WELDING GENERA TOR − CC MODELS 6-1. Front Panel Controls For CC Models (See Section 6-2) 201 841 / 802 31 1 6 5 47 15 16 2 1 3 .
OM-4406 Page 31 Return T o T able Of Cont ent s 6-2. Description Of Front Panel Controls For CC Models (See Section 6-1 ) Engine Starting Controls 1 Magnetic Shutdown Switch Use switch during start-up to bypass engine shutdown system. System stops engine if oil pressure is too low or coolant temperature is too high.
OM-4406 Page 32 Return T o T able Of C ont ents 6-3. Remote Amperage Control On CC Models (Optional) 1 Remote Amperage Adjust Receptacle RC13 Connect optional remote control to RC13 (see Section 5-10 ). Example: Combination Remote Amperage Control (Stick) Adjust Optional Remote Control Set Switches Set Range Set Control Ref.
OM-4406 Page 33 Return T o T able Of Cont ent s Notes.
OM-4406 Page 34 Return T o T able Of Contents SECTION 7 − OPERA TING WELDING GENERA TOR − CC/CV MODELS 7-1. Front Panel Controls For CC/CV Models (See Section 7-2) 201 579 / 802 31 1-D 6 5 47 2 1 .
OM-4406 Page 35 Return T o T able Of Cont ent s 7-2. Description Of Front Panel Controls For CC/CV Models (See Section 7-1 ) Engine Starting Controls 1 Magnetic Shutdown Switch Use switch during start-up to bypass engine shutdown system. System stops engine if oil pressure is too low or engine temperature is too high.
OM-4406 Page 36 Return T o T able Of C ont ents 7-3. Process/Contactor Switch On CC/CV Models 1 Process/Contactor Switch W eld output terminals are ener- gized when Process/Contactor switch i s in an Electrode Hot posi- tion and the engine is running.
OM-4406 Page 37 Return T o T able Of Contents 7-4. Remote V oltage/Amperage Control On CC/CV Models (Optional) 1 Remote 14 Receptacle RC14 Connect optional remote control to RC14 (see Section 5-1 1).
OM-4406 Page 38 Return T o T able Of Contents SECTION 8 − OPERA TING AUXILIAR Y EQUIPMENT 8-1. 120 V olt And 240 V olt Receptacles 191 624-A 2 1 120 V 20 A AC GFCI Receptacle GFCI1 2 240 V 30 A AC T wistlock Receptacle RC1 Receptacles supply 60 Hz single- phase power at weld/power speed.
OM-4406 Page 39 Return T o T able Of Contents 8-2. Connecting T o Optional Three-Phase Generator (CC/CV Models Only) Ref. 197 399 / 802 332-E Place Process/Contactor switch in Electrode Hot - Stick position when using three − phase genera- tor (see Section 7-3).
OM-4406 Page 40 Return T o T able Of Contents 8-3. Optional Generator Power Receptacles 2 1 120 V 20 A AC GFCI Receptacle GFCI1 2 240 V 16 A AC European Receptacle RC1 3 240 V 15 A AC Australian Receptacle RC1 4 240 V 15 A AC South African Receptacle RC1 Receptacles supply 60 Hz single- phase power at weld/power speed.
OM-4406 Page 41 Return T o T able Of Contents SECTION 9 − MAINTENANCE & TROUBLESHOOTING 9-1. Maintenance Label.
OM-4406 Page 42 Return T o T able Of C ont ents 9-2. Routine Maintenance Follow the storage procedure in the engine owner ’s manual if the unit will not be used for an extended period.
OM-4406 Page 43 Return T o T able Of Contents Every 1000 h Check Radiator Fluid Level. See Section 5-7. Change Fuel Filters. See Section 9-7. Service W elding Generator Brushes And Slip Rings. Service More Often In Dirty Conditions.* Blow Out Or V acuum Inside.
OM-4406 Page 44 Return T o T able Of C ont ents 9-4. Servicing Air Cleaner Stop engine. Do not run engine without air cleaner or with dirty element.
OM-4406 Page 45 Return T o T able Of Cont ent s 9-5. Inspecting And Cleaning Optional Spark Arrestor Muffler Ref. 802 31 1 / Ref. 802 160 / Ref. 201 841 Stop engine and let cool. 1 Spark Arrestor Muffler 2 Cleanout Plug Remove plug and remove any dirt covering cleanout hole.
OM-4406 Page 46 Return T o T able Of Contents 9-6. Adjusting Engine Speed 802 490 / 802 538-A After tuning engine, check engine speed with tachometer or frequen- cy meter . See table for proper no load speed. If necessary , adjust speed as follows: Start engine and run until warm.
OM-4406 Page 47 Return T o T able Of Contents 9-7. Servicing Fuel And Lubrication Systems 802 490 / Ref. 801 434 Stop engine and let cool. After servicing, start engine and check for fuel leaks. Stop engine, tighten connec- tions as necessary , and wipe up spilled fuel.
OM-4406 Page 48 Return T o T able Of C ont ents 9-8. Overload Protection 802 170-D / Ref. 802 31 1 21 9 8 7 4 Stop engine. When a circuit breaker or fuse opens, it usually indicates a more serious problem exists. Contact Factory Authorized Service Agent.
OM-4406 Page 49 Return T o T able Of Contents 9-9. Diagnosing Causes Of Engine Fault Shutdowns Ref. 201 841 Use the front panel engine lights to help determine the cause of an au- tomatic engine shutdown. Correct the cause of the shut- down before operating the welding generator .
OM-4406 Page 50 Return T o T able Of Contents 9-10. T roubleshooting A. Welding − CC Models T rouble Remedy No weld output; generator power output okay at ac receptacles. Check position of Ampere Range switch. Check position of optional Polarity switch.
OM-4406 Page 51 Return T o T able Of Contents B. Welding − CC/CV Models T rouble Remedy No weld output; generator power output okay at ac receptacles. Place Process/Contactor switch in a Electrode Hot position, or place switch in a Remote position and connect remote contactor to optional Remote 14 receptacle RC14 (see Sections 5-1 1 and 7-1).
OM-4406 Page 52 Return T o T able Of Contents T rouble Remedy Min or max CV weld output only . Check position of V oltage/Amperage Adjust control and V oltage/Amperage Adjust switch. Repair or replace remote control device. Have Factory Authorized Service Agent check field current regulator board PC1.
OM-4406 Page 53 Return T o T able Of Contents T rouble Remedy Engine cranks but does not start. Press Magnetic Shutdown switch MS1 when starting engine. Check fuel level. Reset circuit breaker CB13 (see Section 9-8). Have Factory Authorized Service Agent check engine- wiring harness and components.
OM-4406 Page 54 Return T o T able Of Contents SECTION 10 − ELECTRICAL DIAGRAMS Figure 10-1. Circuit Diagram For CC Welding Generator.
OM-4406 Page 55 Return T o T able Of C ont ents 215 296-B.
OM-4406 Page 56 Return T o T able Of C ont ents Figure 10-2. Circuit Diagram For CC/CV Welding Generator.
OM-4406 Page 57 Return T o T able Of C ont ents 215 297-B.
OM-4406 Page 58 Return T o T able Of C ont ents SECTION 1 1 − RUN-IN PROCEDURE run_in1 8/01 1 1-1. Wetstacking Do not perform run-in procedure at less than 20 volts weld output and do not exceed duty cycle or equip- ment damage may occur .
OM-4406 Page 59 Return T o T able Of Contents 1 1-2. Run-In Procedure Using Load Bank S-0683 Stop engine. Do not touch hot exhaust pipe, engine parts, or load bank/grid.
OM-4406 Page 60 Return T o T able Of C ont ents 1 1-3. Run-In Procedure Using Resistance Grid S-0684 Stop engine. Do not touch hot exhaust pipe, engine parts, or load bank/grid.
OM-4406 Page 61 Return T o T able Of Cont ent s SECTION 12 − GENERA T OR POWER GUIDELINES The views in this section are intended to be representative of all engine-driven welding generators. Your unit may differ from those shown. NOTE 12-1. Selecting Equipment gen_pwr 1 1/02 − Ref.
OM-4406 Page 62 Return T o T able Of Contents 12-3. Grounding When Supplying Building Systems ST-800 576-B 1 Equipment Grounding T erminal 2 Grounding Cable Use #10 AWG or larger insulated copper wire. 3 Ground Device Ground generator to system earth ground if supplying power to a premises (home, shop, farm) wiring system.
OM-4406 Page 63 Return T o T able Of Contents 12-5. Approximate Power Requirements For Industrial Motors Industrial Motors Rating Star ting W atts Running W atts Split Phase 1/8 HP 800 300 1/6 HP 1225.
OM-4406 Page 64 Return T o T able Of Contents 12-7. Approximate Power Requirements For Contractor Equipment Contractor Rating Starting Watts Running W atts Hand Drill 1/4 in 350 350 3/8 in 400 400 1/2.
OM-4406 Page 65 Return T o T able Of Contents 12-8. Power Required T o Start Motor S-0624 1 Motor Start Code 2 Running Amperage 3 Motor HP 4 Motor V oltage T o find starting amperage: Step 1: Find code and use table to find kV A/HP . If code is not listed, multiply running amperage by six to find starting amperage.
OM-4406 Page 66 Return T o T able Of C ont ents 12-10. T ypical Connections T o Supply Standby Power Have only qualified persons perform these connections according to all applicable codes and safety practic- es. Properly install and ground this equipment according to its Owner ’ s Manual and national, state, and local codes.
OM-4406 Page 67 Return T o T able Of Cont ent s 12-1 1. Selecting Extension Cord (Use Shortest Cord Possible) Cord Lengths for 120 V olt Loads If unit does not have GFCI receptacles, use GFCI-protected extension cord.
OM-4406 Page 68 Return T o T able Of Contents SECTION 13 − P ARTS LIST Hardware is common and not available unless listed. 17 18 19 15 16 26 25 24 22 23 1 2 3 4 5 6 7 10 11 12 13 14 20 21 103 102 101 100 104 99 98 107 (CC ONL Y) 108 106 (FIG 13-2 OR 13-3) 105 12 109 11 0 1 1 1 (FIG.
OM-4406 Page 69 Return T o T able Of C ont ents 802 550-E 85 (Fig. 13-4) 84 43 56 57 41 55 33 36 37 72 73 76 74 75 77 78 58 59 38 60 40 54 79 80 82 86 32 27 28 29 30 31 34 35 87 88 89 90 91 92 93 94 9.
OM-4406 Page 70 Return T o T able Of C ont ents Description Part No. Dia. Mkgs. Item No. Figure 13-1. Main Assembly Quantity 1 189 824 P ANEL, gen LH 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-4406 Page 71 Return T o T able Of Contents Description Part No. Dia. Mkgs. Item No. Figure 13-1. Main Assembly (Continued) Quantity 40 214 658 HOSE, radiator upper 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-4406 Page 72 Return T o T able Of Contents Description Part No. Dia. Mkgs. Item No. Figure 13-1. Main Assembly (Continued) Quantity 85 Figure13-6 GENERA TOR 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-4406 Page 73 Return T o T able Of C ont ents Ref. 802 551-E 2 1 11 6 3 7 14 21 13 16 12 5 24 15 10 9 18 17 4 22 19 8 20 23 Figure 13-2. Control Box Assembly − CC Models Description Part No. Dia. Mkgs. Item No. Figure 13-2. Control Box Assembly − CC Models (Figure 13-1 Item 106) Quantity 1 F1, F2 *085 874 FUSE, mintr cer slo-blo 10A 250V 2 .
OM-4406 Page 74 Return T o T able Of Contents Description Part No. Dia. Mkgs. Item No. Figure 13-2. Control Box Assembly − CC Models (Continued) Quantity 190 260 HARNESS, unit weld control (consisting of) 1 . . . . . . . . . . . . . . . . . . . . . .
OM-4406 Page 75 Return T o T able Of C ont ents Description Part No. Dia. Mkgs. Item No. Figure 13-3. Control Box Assembly − CC/CV Models (Figure 13-1 Item 106) Quantity 1 F1, F2 *085 874 FUSE, mintr cer slo-blo 10A 250V 2 . . . . . . . . . . . . . .
OM-4406 Page 76 Return T o T able Of C ont ents Hardware is common and not available unless listed. 802 266-E 1 3 4 5 12 15 18 23 24 26 29 32 35 37 38 39 45 46 47 17 25 30 31 16 20 2 22 27 28 13 19 14 6 7 8 9 10 21 34 33 11 40 41 42 43 44 36 Figure 13-4.
OM-4406 Page 77 Return T o T able Of Contents Description Part No. Dia. Mkgs. Item No. Figure 13-4 . Panel, Front w/Components − CC Models (Continued) Quantity 7 S6 01 1 622 SWITCH, tgl DPDT 15A 125V AC (included in control box harness, . . . . . . .
OM-4406 Page 78 Return T o T able Of C ont ents Hardware is common and not available unless listed. 802 332-F 1 2 3 4 5 6 7 9 48 50 51 52 53 59 60 61 62 13 18 19 20 21 22 23 24 25 26 27 30 28 29 15 16 34 33 32 17 35 42 43 41 40 39 38 37 36 44 47 14 10 49 11 8 31 45 46 12 54 55 56 57 58 63 Figure 13-5.
OM-4406 Page 79 Return T o T able Of Contents Description Part No. Dia. Mkgs. Item No. Figure 13-5 . Panel, Front w/Components − CC/CV Models (Continued) Quantity 5 R1 193 1 18 POT , cp flat 1t 2w 1k ohm linear 1 . . . . . . . . . . . . . . . . . . .
OM-4406 Page 80 Return T o T able Of Contents Description Part No. Dia. Mkgs. Item No. Figure 13-5 . Panel, Front w/Components − CC/CV Models (Continued) Quantity 50 170 391 CONN, circ ms protective cap size 20 1 . . . . . . . . . . . . . . . . . . .
OM-4406 Page 81 Return T o T able Of C ont ents 802 552-A Hardware is common and not available unless listed. 5 6 8 9 24 28 30 31 32 33 1 2 7 25 26 35 36 4 3 10 27 21 29 34 20 17 18 11 15 16 12 13 14 19 22 23 Figure 13-6. Generator Description Part No.
OM-4406 Page 82 Return T o T able Of Contents Description Part No. Dia. Mkgs. Item No. Figure 13-6. Generator (Continued) Quantity 21 197 486 ADAPTER, Engine Perkins 104.22 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-4406 Page 83 Return T o T able Of C ont ents Hardware is common and not available unless listed. 802 279-A 1 2 3 4 6 5 7 8 9 Figure 13-7. Main Rectifier Assembly.
.
Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 8/03 Y our distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor .
PRINTED IN USA 2004 Miller Electric Mfg. Co. 1/04 Miller Elect ric Mfg. Co. An Illinois T ool W orks Compan y 1635 West S pencer Street Applet on, WI 54914 USA International He adquarters − US A.
Een belangrijk punt na aankoop van elk apparaat Miller Electric Big 40 CAT (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Miller Electric Big 40 CAT heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Miller Electric Big 40 CAT vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Miller Electric Big 40 CAT leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Miller Electric Big 40 CAT krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Miller Electric Big 40 CAT bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Miller Electric Big 40 CAT kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Miller Electric Big 40 CAT . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.