ROI (Remo te Operato r Interface) Processes Description MIG (GMA W) W elding Wire Feeder OM-217 834G 2006 − 06 File: Advanced Manufacturing Systems V isit our website at www.
Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual specification sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .
T ABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
OM-217 834 Page 1 SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING som _3/05 Y W arning: Protect yourself and others from injury — read and follow these precautions. 1-1. Symbol Usage Means W arning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols.
OM-217 834 Page 2 Arc rays from the w elding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin.
OM-217 834 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring − be sure power supply system is properly sized, rated, and protected to handle this unit.
OM-217 834 Page 4 1-5. Principal Safety Standards Safety i n W elding, Cutting, and Allied Processes, ANSI Standard Z49.1, from Global Engineering Documents (phone: 1-877-413-5184, website: www .
OM-217 834 Pa ge 5 SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE A V ANT UTILISA TION fre_som _3/05 Y A vertissement : se protéger et protéger les autres contre le risque de blessure — lire et respecter ces consignes.
OM-217 834 Page 6 Le rayonnement de l’arc du procédé de soudage génère des rayons visibles et invisibles intenses (ultraviolets et infrarouges) susceptibles de provo- quer des brûlures dans les yeux et sur la peau. Des étincelles sont projetées pendant le soudage.
OM-217 834 Pa ge 7 2-3 . Dangers s uppl émentaire s en r el ation avec l’install ation, le f onc t i onnement et l a mainte nance Risque D’INCENDIE OU D’EXPLO- SION. D Ne pas placer l’appareil sur , au-dessus ou à proximité de surfaces inflammables.
OM-217 834 Page 8 2-5. Princi pales n ormes de sécurit é Safety in W elding, Cutting, and Allied Processes, ANSI Standard Z49.1, de Global Engineering Documents (téléphone : 1-877-413-5184, site In- ternet : www .
OM-217 834 Page 9 SECTION 3 − INTRODUCTION 3-1. Specifications T ype of Input Power W elding Power Source T ype Wire Feed Speed Range Wire Diameter Range W elding Circuit Rating Overall Dimensions W eight 40 V olts DC 10 Amperes Axcess Series Standard: 40 T o 1400 ipm (1.
OM-217 834 Page 10 4-2. Installing Insulator Kit 804 165-A Y T urn Off and disconnect input power . 1 ROI Control 2 Insulator Plate 3 Mounting Plate 4 1/4-20x3/4 in Screw (4) 5 Nylon Shoulder Washer (4) 6 3/8 in Flat W asher (4) Place insulator plate between ROI base and metal mounting surface.
OM-217 834 Page 1 1 Ref. 803 697-E T y pical Swingarc installati on s hown; howev er , various inst allations ar e poss ible d epending on the applicat ion. 1 Remote Operator Interface 2 Swingarc Swivel Assembly 3 Boom 4 AA40G Wire Drive Assembly 5 Trigger Cable 4-3.
OM-217 834 Page 12 4-5. Rear Panel Connections Ref. 803 503-A 1 9-Pin Network Receptacle 2 Motor Control/Shielding Gas V alve Receptacle 3 Rating Label Location 1 2 3 4-6.
OM-217 834 Page 13 4-8. Power Source Display At Power Up 1 Upper Display 2 Lower Display Program Process Wire T ype Gas T ype T rigger Control Adjust V olts Time WFS Amps Process Set Up Feeder Set Up .
OM-217 834 Page 14 SECTION 5 − OPERA TION 5-1. Operational T erms The following is a list of terms and their definitions as they apply to the interface unit in the wire feeder: General T erms: Arc Adjust T erm used to represent arc length adjustments in pulse programs.
OM-217 834 Page 15 General T erms: Sequence Selecting Sequence will allow setting of preflow , start, crater , and postflow times and parameters. Preflow Setting a time value for gas flow prior to arc start.
OM-217 834 Page 16 5-3. Front Panel Sections See Section 5-5 See Section 5-6 See Section 5-9 See Section 5-8 See Section 5-7 See Section 5-4 Program Process Wire T ype Gas T ype T rigger Control Adjus.
OM-217 834 Page 17 5-4. Program Push Button 1 3 Program 2 1 Program Display The number of the active program is displayed. 2 Program Push Button 3 Program Push Button LED The LED lights to indicate that programs can be changed using the Adjust knob. Momentarily pres s button to illuminate LED.
OM-217 834 Page 18 5-6. Lower Display 1 Lower Display The lower display shows WFS (wire feed speed), AMPS (amperage), ARC CTL (arc control), or Time. The feeder displays only preset wire speed at idle (not welding). While welding, the average amperage is displayed.
OM-217 834 Page 19 5-7. Feeder Set Up Push Button 1 Feeder Set Up Push Button LED 2 Feeder Set Up Push Button • Press button to choose Sequence. Feeder Set Up push-button LED will illuminate. 3 Sequence LED • When the Feeder Set Up button is pressed once, the Sequence LED will illuminate and the upper display will show sequence options.
OM-217 834 Page 20 5-9. Process Set Up Push Button • Press the Process Set Up push button the first time will illuminate the button LED and the Process LED. The upper and lower displays will be used for Accu-pulse and only the lower display for MIG, Pulse and RM D (optional) to show the current process installed in this program.
OM-217 834 Page 21 5-10. Jog/Purge 803 693-A 1 Jog/Purge Push Button 2 Adjust Control 3 Gun Trigger Receptacle 1 2 3 The Jog/Purge switch provides the following functions: • Pressing left side of the Jog/Purge switch allows the operator to feed wire without energizing the weld power or gas valve circuit.
OM-217 834 Page 22 5-1 1. Reset Mode 198 993 / 803 246-B . Reset mode is not active when Program Lock is enabled. Th e reset mode allows the operator to reload factory program settings for all eight active programs in the unit. . System configuration data will be lost during the Reset operation.
OM-217 834 Page 23 SECTION 6 − SETTING SEQUENCE P ARAMETERS 6-1. Sequence Parameters In A Program . For more information on Sequence mode, see Feeder Set Up Push Button in Section 5-7 . We ld Time can only be set by us ing an o ptional PDA with File Management/WaveWriter softwar e.
OM-217 834 Page 24 SECTION 7 − MAINTENANCE 7-1. Routine Maintenance Y Disconnect power before maintaining. . Maintain more often during severe conditions.
OM-217 834 Page 25 7-2. Diagnostics ERR T ACH • The tach error occurs 2 seconds after the loss of tachometer feedback. The motor speed is re gul a ted through the monitoring of voltage and current. Press Jog/Purge button to clear error . ERR MOTR • The motor error indicates that the motor has been drawing too much current for too long.
OM-217 834 Page 26 7-2. Diagnostics (Continued) WELD W AIT • The weld wait erro r indicates unit was not ready for a weld sequence. Press Jog/ Purge button to clear error . MOTR COM • The motor communication erro r indi- cates motor board lost data communica- tions.
OM-217 834 Page 27 Notes.
OM-217 834 Page 28 SECTION 8 − ELECTRICAL DIAGRAM Figure 8-1. Circuit Diagram.
OM-217 834 Page 29 214 842-E.
OM-217 834 Page 30 SECTION 9 − P ARTS LIST 803 696-B . Hardware is common and not available unless listed. 1 2 3 4 5 7 10 13 14 15 16 17 18 19 20 6 8 9 11 12 Figure 9-1. Remote Operator Interface Description Part No. Dia. Mkgs. Item No. Figure 9-1. Remote Operator Interface Quantity 1 214 839 WRAPPER, feeder 1 .
OM-217 834 Page 31 Description Part No. Dia. Mkgs. Item No. Figure 9-1. Remote Operator Interface (Continued) Quantity 14 PC1 212 459 CIRCUIT CARD ASSY , trigger filter 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Notes.
Notes.
Notes.
Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 2006 − 01 Y our distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours.
PRINTED IN USA © 2006 Miller Electric Mfg. Co. 2006 − 01 Miller Elect ric Mfg. Co. An Illinois T ool Wor k s Comp any 1635 W es t Spencer St reet Applet on, WI 5 4914 USA International He adquarter.
Een belangrijk punt na aankoop van elk apparaat Miller Electric Remote Operator Interface (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Miller Electric Remote Operator Interface heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Miller Electric Remote Operator Interface vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Miller Electric Remote Operator Interface leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Miller Electric Remote Operator Interface krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Miller Electric Remote Operator Interface bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Miller Electric Remote Operator Interface kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Miller Electric Remote Operator Interface . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.