Foreword Mitsubishi Elec tric, MA00816 Installation manual for the E 1000 series oper ator terminals F oreword The E1000 operator terminal is developed to satisfy the demands of human - machine communication. Built-in functions such as displaying and controlling text, dynamic indication, time channels, alar m and r ecipe handling are included.
Table of Contents Mitsubishi Elec tric, MA00816 Ta b l e o f C o n t e n t s 1 Safety Precautions................................................................................. 5 1.1 UL Installation ..................................................
Table of Contents Mitsubishi Electric, MA 00816.
Safety P recautions Mitsubishi Elec tric, MA00816 5 1 Safety Precautions Both the installer and the owner and/or operator of the operator terminal must read and understand this installation manual.
Safety P recautions 6 Mitsubishi Electric, MA 00816 1.4 Serv ice and Maintenance – Only qualified personnel should carry out repairs. – The agreed warranty applies. – Before carrying out any cleaning or maintenance operations, disconnect the equipment from the electrical supply .
I nstallation Mitsubishi Elec tric, MA00816 7 2 Installation 2.1 Space Requirements – Installation plate thickness: 1. 5 - 7.5 mm (0.06 - 0.3 inch) – S pace requirements when installing the operator terminal: Caution The openings on the enclosure are fo r air convection.
I nstallation 8 Mitsubishi Electric, MA 00816 3. Secur e the operator terminal in positi on, using all the fastening holes and the provided brackets and scr ews: 4. Connect th e cables in the specified order . U se an M5 screw and a grounding conductor (as short as possible) with a cross-section of minimum 2.
I nstallation Mitsubishi Elec tric, MA00816 9 2.2.1 Mode Switches All mode switches must be in OFF po sition during operator terminal use. The mode switches should not be touc hed unless by qualified personell.
I nstallation 10 Mitsubishi Electric, MA 00816.
T echnical Data Mitsubishi Elec tric, MA00816 11 3 T echnical Data Pa r a m e t e r E1032 Front panel, W x H x D 202 x 187 x 6 mm Mounting depth 56.9 mm (156.9 mm including clearance) Front panel s eal IP 66 R ear panel seal IP 20 K eyboard material Membrane switch keyb oard with metal domes.
T echnical Data 12 Mitsubishi Electric, MA 00816.
Chemical Resistance Mitsubishi Elec tric, MA00816 13 4 Chemical Resistance 4.1 Metal Casing The frame and casing material is powd er-coated aluminum. This po wder paint withstands exposure of up to 24 hours duration to the follo wing chemicals without visible change: 4.
Chemical Resistance 14 Mitsubishi Electric, MA 00816 4.2.2 Autotex F157 Autotex F157 co vers th e membrane keyboard. Solvent Resistance Autotex F157 withstands exposur e of more than 24 hours duration.
Chemical Resistance Mitsubishi Elec tric, MA00816 15 V er y slight discoloration was noted unde r critical viewing conditions with the following materials: Outdoor Use In common with all poly ester based films, Au totex F157 is not suitable for use in conditions of long term exposure to direct sunlight.
Chemical Resistance 16 Mitsubishi Electric, MA 00816.
Oper ator T erminal Drawings Mitsubishi Elec tric, MA00816 17 5 Oper ator T erminal Dr awings 5.1 Communication P orts Dr awing N o . S-05005, Date 2004-10-27 RS-232 RS-422 RS-422/485 RS-485 Ethernet .
Oper ator T erminal Drawings 18 Mitsubishi Electric, MA 00816 5.2 E1032 Outline Dr awing N o. P-06629, Date 2005-10-05.
Oper ator T erminal Drawings Mitsubishi Elec tric, MA00816 19 5.3 E1032 T ext Strip Dr awing N o . S-06627, Date 2005-07-19 4,5 19,75 20,5 20,5 20,5 20,5 20,5 19,75 179 Text max 18,5x8,0 Text max 17,0.
Mitsubishi Electric Automation , Inc. 500 Corporate Woods Parkway V ernon Hills , IL 60061, USA Mitsubishi E lectric Europe B.V . Gothaer Strasse 8 D-40880 Ratingen, Germany MITSUBISHI ELECTRIC.
Een belangrijk punt na aankoop van elk apparaat Mitsubishi Electronics E1032 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Mitsubishi Electronics E1032 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Mitsubishi Electronics E1032 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Mitsubishi Electronics E1032 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Mitsubishi Electronics E1032 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Mitsubishi Electronics E1032 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Mitsubishi Electronics E1032 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Mitsubishi Electronics E1032 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.