Gebruiksaanwijzing /service van het product PFD-P250500VM-A van de fabrikant Mitsubishi Electronics
Ga naar pagina of 14
Air -Conditioner s INDOOR UNIT PFD-P250 • 500VM-A OPERA TION MANU AL F or safe and correct use, please read this oper ation manual thoroughly before oper ating the air-conditioner unit. BEDIENUNGSHANDB UCH Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme gründlich durchlesen.
2 1 [Room temperature adjustment] Button 2 [Timer/continuous] Button 3 [Selecting operation] Button 4 [Time selection] Button [Time-setting] Button 5 [Louver] Button 6 [F an speed adjustment] Button 7.
3 A P ower display lamp B Operation display lamp C Check displa y lamp D F ault display lamp E Normal / Local switch F No.1 F ault displa y lamp G No.2 F ault displa y lamp * When Local operation is av ailable at maintenance, please set “ Nor mal / Local ” s witch to “ Local ” .
4 [Fig. A] SWC SWC B C D E A A Deflection load (W) 3 - 4kg K K K K K A Address board B Control board C Address board D Option: Inlet temperature control E Standard: Outlet temperature control [Fig. B-1] Par allel Pulley Cast iron pulley K (minutes) 10 or less Remarks Equivalent to 3 mm displacement per meter .
5 GB D F I NL E P GR RU TR 1. Safety precautions s Before operating the unit, make sure y ou read all the “Safety precautions”. s “Safety precautions” lists impor tant points about safety .
6 GB D F I NL E P GR RU TR TIMER SET PAR-20MAA ON/OFF TEST RUN FILTER CHECK TEST TEMP. Nor mal Local C 3 2 E C A 1 6 87 4 B • Ensure that the drain trap is properl y water-sealed. - If the drain trap is modified, or is not water-sealed, the tr ap will not function and a water leak ma y occur.
7 GB D F I NL E P GR RU TR 3.2. Selecting operation When selecting operation 1. Press the 3 3 3 3 3 [selecting operation] b utton Consecutive press of the selecting operation b utton switches the operation ov er to E “ , ” “ , ” “ , ” ( “ ” ), and ( “ ” ).
8 GB D F I NL E P GR RU TR 7. Caring f or the unit Alwa ys have filter maintenance performed by a service per son. Before care-taking, turn the power supply OFF . Caution: • Before y ou star t cleaning, stop operation and turn OFF the power suppl y .
9 GB D F I NL E P GR RU TR 8. T roubleshooting Before y ou ask for repair service, c heck the following points: State of Machine It does not run. Air flows out but it does not cool enough. Cool air does not come out. It runs br iefly , but soon stops.
10 GB D F I NL E P GR RU TR 10. Chec king Drainage Check that water is ab le to drain smoothly . If w ater is unable to drain smoothly , check for b lockage of the groo ves in the drain pan and the piping trap b y paper par ticles etc. Carefully clean the groov es in the drain pan and the piping trap to pre vent further blockage.
11 GB D F I NL E P GR RU TR Unit Par ts F an motor Bearing F an belt Air filter Drain pan Drain hose Linear expansion valv e Heat exchanger Float s witch Displa y lamp Compres- sor F an motor Linear e.
12 GB D F I NL E P GR RU TR 16. Specifications Notes: *1 Cooling capacity indicates the maximum v alue at operation under the follo wing condition. Cooling: Indoor : 27 ° C DB/19 ° C WB Outdoor: 35 ° C DB *2 The operating noise is the data that was obtained in an anechoic room.
WT04232X01 Printed in Japan HEAD OFFICE: MITSUBISHI DENKI BLDG., 2-2-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN.
.
Een belangrijk punt na aankoop van elk apparaat Mitsubishi Electronics PFD-P250500VM-A (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Mitsubishi Electronics PFD-P250500VM-A heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Mitsubishi Electronics PFD-P250500VM-A vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Mitsubishi Electronics PFD-P250500VM-A leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Mitsubishi Electronics PFD-P250500VM-A krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Mitsubishi Electronics PFD-P250500VM-A bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Mitsubishi Electronics PFD-P250500VM-A kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Mitsubishi Electronics PFD-P250500VM-A . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.