Gebruiksaanwijzing /service van het product 10 van de fabrikant Mitsumi electronic
Ga naar pagina of 26
MAC Ope ra tor Termina l Human-Machine-Interfac e In stal la tion Manua l MAC 1 0 MAC 1 2 MITSU BIS HI ELECTRI C MITSU BIS HI ELECTRIC EU RO PE B.V . FACTORY AU TO MA TI O N.
1 GB Contents Safety precautions ........................................... 2 Introduction ..................................................... 4 Function overvie w ........................................... 5 Installation .........................
2 GB Safety pr ecautions General – Check the delivery for tran sport damage. If damage is found, advise your supplier. – The product fulfils the requirements of article 4 of EMC directive 89/336/EEC. – Do not use the pro duct in an explosive env i- ronment.
3 GB Service and maintenance – The agreed warrenty applies. – Clean the display and face with a soft cloth and mild detergent. – Repairs should be made by qualified person- nel. At disassembly and scrapping – Local regulations apply concerning recy c- ling of products or part.
4 GB Intr oduction This leaflet describes the operator´s panels MA C 10/MT A-10 and MA C 12/MT A-12. Hereafter these products are referred to as the terminal. In the manual we refer to the software package MA C Programmer/SW -MT A for DOS and MA C Programmer+/SW -MT A-WIN for W indows.
5 GB Summary of functions T extblock T extblock is used to build up dialogs. A T ext- block can consist of an arbitrary number of text lines of up to 16 characters long. Static text Static text is text written in textblock which is not changed when executing the program.
6 GB Installation The terminals are connected to FX0, FX0N or FX PLC system. Connection to a FX0/FX0N PLC system Connect the MA C 10/12-CAB (8-p in MINI- DIN) cable to the outlet in the bo ttom of the ter- minal. The cable is straight; the contact at each end is compatible with both the terminal and the PLC system.
7 GB Connection to a FX PLC system The terminal is connected to a FX PLC system using the FX-20P-CABN cable. The cable has a macimum length of 3 meter and the commu ni- cation speed i 9600 baud. The terminal is powered by the PLC system via the cable.
8 GB K eyboard The terminal keyboard incorporates 6 mem- brane keys which are used to performe the follo- wing functions: Set manoeuvrable digital ob ject (ON). Increase value of manoeuvrable analog object. Execute jump. Select/ex ecute choice from a multiple choice object.
9 GB Settings All settings for the terminal must be done in the PC software. It is assumed that the PC software for W indows is installed on your PC and that you have started up with a new project. See the PC software maunal for further details. A number of basic settings have to be entered before using the terminal.
10 GB A small example The following section giv es a small example of how to start creating applications quickly . The example follows the whole sequence from buil- ding up an application to executing to the PLC system. The terminal must be connected to a personal computer with the PC software.
11 GB the signal is 1, in this example ON. 10. Press OK to close the dialog box. The dy na- mic object is now shown by # and two - on the screen. When the program is ready you can connect the terminal to the PLC sy stem. Mac10eng Seit e 11 Freitag, 5.
12 GB Over view Mode selection Keep the ke ys shown to the left pressed during terminal power -up to enter the mode Communi- cation with MP . The terminal norm ally enters Run mode during power- up. For a complete list of other modes possible see User´s manual for the terminal.
13 GB System block Certain blocks are reserved for special purpo- ses: 0 Main menu 990 Reserved for compatibility with other terminals 991 T ime channels 992-999 Reserved for compatibility with other terminals Mac10eng Seit e 13 Freitag, 5.
14 GB T e chnical data Front panel W idth 96 x height 72 x depth 3 mm. Mounting depth MA C 10/MT A-10: Max 37 mm. MA C 12/MT A-12: Max 41 mm. Mounting holes 92 ±1 mm x 68 ±1 mm. Front panel seal IP 65 Rear panel seal IP 20 Front panel material 1,5 mm anodized aluminium and membrane keyboard.
15 GB Real time clock Minimum 10 years lifetime. Supply voltage +5 VDC from P LC system CPU port via com- munication cable. Internal logic voltage +5 VDC ±5%. Po wer consumption MA C 10/MT A-10: 70 mA. MA C 12/MT A-12: 150 mA. Ambient temperature 0º to +50ºC Storage temperature -20º to +60ºC Air humidity Max 90% without condensation.
16 GB Mac10eng Seit e 16 Freitag, 5. Februar 1999 3:29 15.
A-1 Cadbild.fm Seit e 1 Freitag, 5. Febru ar 1999 4:45 16.
A-2 Cadbild.fm Seit e 2 Freitag, 5. Febru ar 1999 4:45 16.
A-3 Cadbild.fm Seit e 3 Freitag, 5. Febru ar 1999 4:45 16.
A-4 Cadbild.fm Seit e 4 Freitag, 5. Febru ar 1999 4:45 16.
A-5 Cadbild.fm Seit e 5 Freitag, 5. Febru ar 1999 4:45 16.
A-6 Cadbild.fm Seit e 6 Freitag, 5. Febru ar 1999 4:45 16.
A-7 Cadbild.fm Seit e 7 Freitag, 5. Febru ar 1999 4:45 16.
A-8 Cadbild.fm Seit e 8 Freitag, 5. Febru ar 1999 4:45 16.
MITSU BIS HI ELECTRI C MITSU BIS HI ELECTRIC EU RO PE B.V . FACTORY AU TO MA TIO N GOT HA ER STR. 8, D- 40880 RA TIN GE N TEL.: (0 21 02) 4 86- 1 0 , FAX: (0 21 02) 4 86-1 1 2.
Een belangrijk punt na aankoop van elk apparaat Mitsumi electronic 10 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Mitsumi electronic 10 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Mitsumi electronic 10 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Mitsumi electronic 10 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Mitsumi electronic 10 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Mitsumi electronic 10 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Mitsumi electronic 10 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Mitsumi electronic 10 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.