Ga naar pagina of 36
7000 SERIES SUPER B-VENT GAS FIREPLACE INSTALLATION AND OPERATING INSTRUCTIONS MODELS: 724BV(4536,5142)(N,P)(V,E)B DUE TO HIGH TEMPE RATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FUR NITURE AND DRAPERIES.
T T A A B B L L E E O O F F C C O O N N T T E E N N T T S S 1 IMPORTANT SAFET Y INFORMATION : .................................................................................................. ............ 2 PRODUCT SPECIFI CATI ONS : ................
I I M M P P O O R R T T A A N N T T S S A A F F E E T T Y Y I I N N F F O O R R M M A A T T I I O O N N 2 IMPORTANT SAFETY INFO RMATION: INSTALLER: Please leave these ins tructions with the owner. OWNER: Please re ad and retains these instructions for future reference.
P P R R O O D D U U C C T T S S P P E E C C I I F F I I C C A A T T I I O O N N S S / / L L I I S S T T I I N N G G & & C C O O D D E E A A P P P P R R O O V V A A L L 3 PRODUCT SPECIFICATIONS : Gas Pressure (Inches W.C.) Models Number Gas Type Control Type Max Btu Max Min Manifold 724BV4536NV Natural Gas Milli-volt 50000 10.
P P R R E E - - I I N N S S T T A A L L L L A A T T I I O O N N I I N N F F O O R R M M A A T T I I O O N N 4 PRE-INSTALLATION INFORMATION: Before You Start: Read this homeowner manual thorough ly and follow all inst ructions carefully. Inspect all co ntents for shipping damage and im mediately i nform your dealer if any dam age is found.
P P R R E E - - I I N N S S T T A A L L L L A A T T I I O O N N I I N N F F O O R R M M A A T T I I O O N N 5 Figure 1: Fireplace Dimensions.
P P R R E E - - I I N N S S T T A A L L L L A A T T I I O O N N I I N N F F O O R R M M A A T T I I O O N N 6 Figure 2: Fireplace Locations and Minimum Clearances Requirements CAUTION: Measure firepla ce dimensi ons and verify framing meth ods & w all covering details before framing cons truction begins .
P P R R E E - - I I N N S S T T A A L L L L A A T T I I O O N N I I N N F F O O R R M M A A T T I I O O N N 7 Figure 3: Wall & Ceiling Minimum Clearances Wall and Ceiling Clearance Requirements: Ensure that minim um clearances shown in Figure 3 are m ain tained.
P P R R E E - - I I N N S S T T A A L L L L A A T T I I O O N N I I N N F F O O R R M M A A T T I I O O N N 8 Mantel Clearances: If a combustible mantel is installed, it must meet the clearance requirements detailed in Figure 4. Figure 4: Mantel Clearance Floor Clearances: The fireplace may be installed on a flat, hard combustible su rface (i.
P P R R E E - - I I N N S S T T A A L L L L A A T T I I O O N N I I N N F F O O R R M M A A T T I I O O N N 9 CAUTION Measure fireplace dimensions and verify framing me thods & wall covering details before fr aming construction b egins. Finishing Material: NOTE Any remote wiring (i.
V V E E N N T T I I N N S S T T A A L L L L A A T T I I O O N N 10 VENT INSTALLATION: WARNING The following venting instruct ions are provided as a general guideline.
V V E E N N T T I I N N S S T T A A L L L L A A T T I I O O N N 11 WARNING Never use more than two (2 ) 45 degree elbows. When using adjust able elbows, ne ver exceed 45 degrees.
V V E E N N T T I I N N S S T T A A L L L L A A T T I I O O N N 12 Figure 8: Installing Pipe Supports WARNING Always maintain minimum clearances around vent system s.
V V E E N N T T I I N N S S T T A A L L L L A A T T I I O O N N 13 Figure 9: Ceiling Firestop L ocation Vent Termination: For Vertical Termination ` Figure 10: Minimum Vent Height for Various Roof Pitches WARNING Major building codes specify a minimum ven t height above the rooftop depe nding on the pitch of the roof.
V V E E N N T T I I N N S S T T A A L L L L A A T T I I O O N N 14 NOTE When working on the roof, cover the opening of the in stalled vent pipes below to prevent debris falling in. To Locate and install Vertical Termination • Locate and mark the vent center point on the un derside of the roof, and drive a nail through th e center point.
G G A A S S L L I I N N E E A A N N D D E E L L E E C C T T R R I I C C A A L L I I N N S S T T A A L L L L A A T T I I O O N N 15 GAS LINE AND ELECTRICAL Gas Line In stallation : NOTE Plumbing connections should only be performed by a qu alified, licensed plumber.
G G A A S S L L I I N N E E A A N N D D E E L L E E C C T T R R I I C C A A L L I I N N S S T T A A L L L L A A T T I I O O N N 16 Figure 12: Gas Pressure Check at Gas Valve Electrical Wiring: Standin.
G G A A S S L L I I N N E E A A N N D D E E L L E E C C T T R R I I C C A A L L I I N N S S T T A A L L L L A A T T I I O O N N 17 Figure 13: Wiring Diagram for Standing Pilot - Millivolt System Optio.
G G A A S S L L I I N N E E A A N N D D E E L L E E C C T T R R I I C C A A L L I I N N S S T T A A L L L L A A T T I I O O N N 18 Pilot must be lit and the valve control knob turned to the “ON” position . Meter lead s must be con nected to the TP and the TH/TP terminals on the control valve.
G G A A S S L L I I N N E E A A N N D D E E L L E E C C T T R R I I C C A A L L I I N N S S T T A A L L L L A A T T I I O O N N 19 Optional DC Remote Systems These instructions supersede the section entitled “Hearth Mount” in th e Milliv olt hand held remote instructions supplied with the remote.
F F I I N N A A L L I I N N S S T T A A L L L L A A T T I I O O N N 20 FINAL INSTALLATION Wall Finishing: Definitions: Combustible Materia ls - Materials made of or surfaced with wood, compressed paper, plant fibers, or other materials t hat are capable of b eing ignite d and bur n ed.
F F I I N N A A L L I I N N S S T T A A L L L L A A T T I I O O N N 21 Log Placement for fiber VDY24/18D3R: Step 1: Line up pins on botto m of Rear Log #1 with pi ns on grate bar and place on grate. Step 2: Place Front Left Log #2 on left front of grate bar li ning up cutout i n bottom of l og with grate bar.
F F I I N N A A L L I I N N S S T T A A L L L L A A T T I I O O N N 22 Glass Bi-Fold Door Instal lation: WARNING Glass doors must be ins talled on all Propane/LPG units and operated in the closed position to eliminate a ny potential for soot spillage into the roo m.
F F I I N N A A L L I I N N S S T T A A L L L L A A T T I I O O N N 23 Damper operation: NOTE For Massachusetts residents onl y: Installation of this vented ga s fireplace in the Commonwealth of Massachusetts requires the damper to be permanently r emoved or welded into the fully open position.
O O P P E E R R A A T T I I N N G G I I N N S S T T R R U U C C T T I I O O N N S S 24 Before Lighting the Fireplace: • Read the IMPORT A NT SA FE TY I N FORMA TIO N section at the be ginning of this home owner manual . • Before lighting, check the fireplace for possi ble gas leaks.
O O P P E E R R A A T T I I N N G G I I N N S S T T R R U U C C T T I I O O N N S S 25 Pilot LIGHTING INSTRUCTIONS MILLIVOLT CONTROL 8. With the control knob pushed in, push in and release the piezo ignitor button to light the pilot.
O O P P E E R R A A T T I I N N G G I I N N S S T T R R U U C C T T I I O O N N S S 26 FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If y ou do not follo w these Instructions exactly, a fire or explosion may result causing property dam a ge, personal injury or loss of life.
M M A A I I N N T T E E N N A A N N C C E E 27 MAINTENANCE WARNING Turn off gas before servicing fireplace. It is recommend ed that a qualified service technician perform these check-ups at the be ginning of eac h heating se ason.
M M A A I I N N T T E E N N A A N N C C E E 28 Vent System: The fireplace and venting syst em should be inspected befo re initial use and at least annually by a qualified field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the airflow.
P P A A R R T T S S L L I I S S T T / / I I L L L L U U S S T T R R A A T T I I O O N N S S 29 PARTS LIST / ILLUSTRATION B Firebox Comp onent s: St andard and Accessories Item Description Qty 4536 514.
P P A A R R T T S S L L I I S S T T / / I I L L L L U U S S T T R R A A T T I I O O N N S S 30 Engine Components: Standing Pilot – Millivolt Control Item Description Qty 4536NV 4536 PV 5142NV 5142PV.
31 Electronic Ignition Control Item Description Qty 4536NE 4536PE 5142NE 5142PE 1 Gas Valve Assembly 1 37D0016 37D 0017 37D001 6 37D0017 2 Pilot Assembl y 1 54D2004 54D2005 54D 2004 54D20 05 3 Burner .
32 TROUBLESHOOTING STANDING PILOT - MILLIVOLT SYMPTOM POSSIBLE CAUSE REMEDY 1. Spark ignitor will not light pilot after repeated trigge ring of piezo. A. Wire disconnected. Open door and ch eck to make sure wire is conn ected to ignitor. B. Defective ignitor.
33 ELECTRONIC IGNITION.
34 GENERAL TROUBLESHOOTING: 1. Glass Soots A. Flame im pingem ent on logs Install log set per the instruction s Inspect the injector an d air intake area. Make sure this area does not have any bl ocka ge f rom debris and clean. Check gas su pply 2. Poor draft due to venting A.
35 LIMITED LIFETIME WARRANTY POLICY Lifetime Warranty The followin g component s are warranted for life to the original owne r, subject to proof of purc hase: Firebo x, Combustion Cham ber, Heat Exchanger, Grate, Stainless Steel Burne rs, and Vented Fiber Ceramic and Refract ory Logs.
Een belangrijk punt na aankoop van elk apparaat Monessen Hearth 7000 Series (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Monessen Hearth 7000 Series heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Monessen Hearth 7000 Series vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Monessen Hearth 7000 Series leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Monessen Hearth 7000 Series krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Monessen Hearth 7000 Series bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Monessen Hearth 7000 Series kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Monessen Hearth 7000 Series . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.