Model MT202TD 1200 BPS Leased Line Modem User Guide.
User Guide MT202TD P/N 82096502 Revision C COPYRIGHT This publication may not be reproduced, in whole or in part, without prior expressed written permission from Multi-T ech Systems, Inc. All rights reserved. Copyright © 2000-2003, by Multi-T ech Systems, Inc.
Contents Chapter 1 - Introduction and Description ......................... 5 Introduction ........................................................................... 5 Description ......................................................................
Chapter 4 - W arranty , Service, and T echnical Support ................................................ 20 Limited W arranty ................................................................. 20 Online W arranty Registration ..........................
Chapter 1 - Introduction & Description 5 Chapter 1 - Introduction and Description Introduction This manual provides instruction for installing, cabling, operating, and troubleshooting Multi-T ech System’ s model MT202TD 1200 bps modem.
MT202TD User Guide 6 Technical Specifications Y our MT202TD modem meets the specifications listed below: Model Number MT202TD Data Rate 0–1200 bps Compatibility Western Electric 202 and 202T Data Se.
Chapter 1 - Introduction & Description 7 Interface EIA RS-232C / ITU-T V .24 Connectors One DB-25 RS-232 C connector (25-pin female connector), external power transformer , RJ1 1 line jack Diagnos.
MT202TD User Guide 8 Chapter 2 - Installation and Connection Introduction The installation of the MT202TD consists of setting DIP switches to the appropriate settings and then making the serial, phone line, and electrical power connections. Power Power is supplied to model MT202TD through an AC power transformer .
Chapter 2 - Installation & Connection 9 Unpacking the Modem Remove all items from the box. Figure 2-1. Unpacking the MT202TD The packing box contains the following items: l One MT202TD modem l One.
MT202TD User Guide 10 Modem LED Indicators Figure 2-2. LED Display The MT202TD has seven diagnostic LED indicators. They are: TD T ransmit Data - This LED blinks when data is being transmitted: on for a space; off for a mark. The state of this LED matches the TD circuit on Pin 2 of the RS- 232C/V .
Chapter 2 - Installation & Connection 11 Controls on PC Board The MT202TD circuitry is on a single printed circuit (PC) board. This board contains one 8-position DIP switch (numbered 1-8), an analog loopback test switch, and a digital loopback test switch.
MT202TD User Guide 12 Computer or Terminal Connections Y our computer or terminal is connected to the MT202TD via the modem’s EIA RS-232C / ITU-T V .24 interface connector . This connector is a standard interface, with a 25-socket female connection.
Chapter 2 - Installation & Connection 13 MT202TD RS-232 Signal Descriptions Pin MTS Circuits Function Signal Name EIA ITU-T Source 2 SD BA 10 3 T ransmitted Data DTE 3 RD BB 10 4 Received Data DCE.
MT202TD User Guide 14 Modem and Phone Line Connection This section describes how to install and connect the MT202TD. Installation Steps: 1. V erify that the remote modem is set for Bell 202- or 202T - compatibility . 2. Connect the modem to the leased line jack using one of the two RJ1 1 cables provided with the modem.
Chapter 2 - Installation & Connection 15 DIP Switch Settings DIP switches are located on the MT202TD circuit board as shown in Figure 2-3. For information about DIP switch settings and functions, refer to the chart on page 19. T o access the switches, remove the modem’ s cover .
MT202TD User Guide 16 DIP Switch and Switch Settings & Functions (See Figure 2–3.) Switch Function Position 1 Local Copy Enable UP* Local Copy Suppress DOWN 2 T wo-Wire Lease Line DOWN Four-Wire.
Chapter 2 - Installation & Connection 17 Leased Line Connections The MT202TD modem operates on leased lines and may be configured in two ways: two-wire or four-wire.
MT202TD User Guide 18 Chapter 3 - Modem T esting Introduction The MT202TD has two diagnostic tests: Local analog loopback and digital loopback. A loopback test involves entering data from your PC and looping that data through the circuits of your modem and/or a remote modem.
19 Chapter 3 - Modem T esting 2 for DIP switch setting information). Computer or T er minal Local MultiModem Digital Analog CONNECT UUUUUUUU UUUU Figure 3-3.
MT202TD User Guide 20 Chapter 4 - W arranty , Service, and T echnical Support Limited Warranty Multi-T ech Systems, Inc., (hereafter MTS) warrants that this product will be free from defects in material or workmanship for a period of two years from date of purchase, or if proof of purchase is not provided, two years from date of shipment.
21 Chapter 4 - Warranty , Service & T echnical Support Service In the event that service is required, products may be shipped, freight prepaid, to our Mounds V iew , Minnesota, factory . Please send modems that require repairs to the following address: Multi-T ech Systems, Inc.
MT202TD User Guide 22 Technical Support Multi-T ech Systems has an excellent staf f of technical support personnel available to help you get the most out of your Multi- T ech product. If you have any questions about the operation of this modem, please contact us at: Email: Phone: support@multitech.
Appendix 23 Appendix - Regulatory Compliance FCC Part 15 – Class A Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
MT202TD User Guide 24 FCC Part 68 Telecom 1. This equipment complies with part 68 of the Federal Communications Commission Rules. On the outside surface of this equipment is a label that contains, among other information, the FCC registration number .
Appendix 25 6. The telephone company may make changes in its facilities, equipment, operations, or procedures that could af fect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make necessary modifications in order to maintain uninterrupted service.
26 MT202TD User Guide Index A Analog Loopback 18 B Back Panel Connectors 14, 15 C Carrier Detect (CD) 10 Carrier Frequencies 6, 7 CCITT V .24 Interface Connector 12 Clear to Send (CTS) 10 Compatibilit.
.
82096502.
Een belangrijk punt na aankoop van elk apparaat Multi-Tech Systems MT202TD 1200 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Multi-Tech Systems MT202TD 1200 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Multi-Tech Systems MT202TD 1200 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Multi-Tech Systems MT202TD 1200 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Multi-Tech Systems MT202TD 1200 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Multi-Tech Systems MT202TD 1200 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Multi-Tech Systems MT202TD 1200 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Multi-Tech Systems MT202TD 1200 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.