OPERA TION AND P AR TS MANUAL THIS MANU AL MUST A CCOMP ANY THE EQUIPMENT A T ALL TIMES. T o find the latest re vision of this publication, visit our website at: www .
P A GE 2 —GB2000 BALLOON LIGHT• OPERA TION AND P AR TS MANU AL — REV . #1 (02/25/14) NOTES.
GB2000 CSA B ALLOON LIGHT• OPERA TION AND P ARTS MANU AL — REV . #1 (02/25/14)— P A GE 3.
P A GE 4 —GB2000 BALLOON LIGHT• OPERA TION AND P AR TS MANU AL — REV . #1 (02/25/14) T ABLE OF CONTENTS GB2000 BALLOON LIGHT T able Of Contents .................................................... 4 P ar ts Ordering Procedures ..................
GB2000 CSA B ALLOON LIGHT• OPERA TION AND P ARTS MANU AL — REV . #1 (02/25/14)— P A GE 5 P AR TS ORDERING PROCEDURES www .multiquip .com Or dering par ts has never been easier! Choose fr om thre.
P A GE 6 —GB2000 BALLOON LIGHT• OPERA TION AND P AR TS MANU AL — REV . #1 (02/25/14) SAFETY INFORMA TION Do not operate or service the equipment before reading the entire manual. Saf ety precautions should be follo wed at all times when operating this equipment.
GB2000 CSA B ALLOON LIGHT• OPERA TION AND P ARTS MANU AL — REV . #1 (02/25/14)— P A GE 7 SAFETY INFORMA TION GENERAL SAFETY CA UTION NEVER operate this equipment without proper protectiv e c.
P A GE 8 —GB2000 BALLOON LIGHT• OPERA TION AND P AR TS MANU AL — REV . #1 (02/25/14) SAFETY INFORMA TION LIGHT T O WER SAFETY D ANGER NEVER operate the equipment in an e xplosiv e atmosphere or near combustib le materials. An e xplosion or fi re could result causing sev ere bodily harm or e ven death.
GB2000 CSA B ALLOON LIGHT• OPERA TION AND P ARTS MANU AL — REV . #1 (02/25/14)— P A GE 9 SAFETY INFORMA TION ENGINE SAFETY D ANGER The engine fuel e xhaust gases contain poisonous carbon mono xide. This gas is color less and odorless, and can cause death if inhaled.
P A GE 10 —GB2000 BALLOON LIGHT• OPERA TION AND P AR TS MANU AL — REV . #1 (02/25/14) SAFETY INFORMA TION FUEL SAFETY D ANGER DO NO T star t the engine near spilled fuel or combustib le fl uids. Diesel fuel is e xtremely fl ammable and its v apors can cause an e xplosion if ignited.
GB2000 CSA B ALLOON LIGHT• OPERA TION AND P ARTS MANU AL — REV . #1 (02/25/14)— P A GE 11 SAFETY INFORMA TION TRANSPORTING SAFETY CA UTION Bef ore lifting, make sure that light to wer par ts are not damaged and screws are not loosened or lost.
P A GE 12 —GB2000 BALLOON LIGHT• OPERA TION AND P AR TS MANU AL — REV . #1 (02/25/14) SAFETY INFORMA TION ELECTRICAL SAFETY D ANGER The electrical voltage required to operate the gener ator can cause se vere injury or ev en death through ph ysical contact with live circuits .
GB2000 CSA B ALLOON LIGHT• OPERA TION AND P ARTS MANU AL — REV . #1 (02/25/14)— P A GE 13 SAFETY INFORMA TION B A TTER Y SAFETY D ANGER DO NO T drop the batter y . There is a possibility that the batter y will e xplode. DO NO T e xpose the batter y to open fl ames, sparks, cigarettes, etc.
P A GE 14 —GB2000 BALLOON LIGHT• OPERA TION AND P AR TS MANU AL — REV . #1 (02/25/14) SPECIFICA TIONS T able 1. Specifications Model GB2000 Lamp T ype 1000 W Metal Halide (X2) Number of Bulbs 2 Current 18.6 A (9.3 A x 2) V oltage 120 V Lumens 214,000 (107,000 x 2) lm Fa n Current 1.
GB2000 CSA B ALLOON LIGHT• OPERA TION AND P ARTS MANU AL — REV . #1 (02/25/14)— P A GE 15 DIMENSIONS T able 2. Dimensions Reference Letter Dimension in.
P A GE 16 —GB2000 BALLOON LIGHT• OPERA TION AND P AR TS MANU AL — REV . #1 (02/25/14) FOOTCANDLE PLOT 1 grid = 40 ft. Illuminance (Footcandle) Diameter (Feet) 30 10 20 32 10 56 5 82 2 121 1 160 0.5 216 0.25 262 0.1 360 30 20 10 5 2 1 0.5 0.25 Figure 2.
GB2000 CSA B ALLOON LIGHT• OPERA TION AND P ARTS MANU AL — REV . #1 (02/25/14)— P A GE 17 GENERAL INFORMA TION The GB2000 lamp fixture is a difused balloon light that is designed to be mounted and oper ated on most conv entional mobile light tower masts .
P A GE 18 —GB2000 BALLOON LIGHT• OPERA TION AND P AR TS MANU AL — REV . #1 (02/25/14) COMPONENTS Figure 3. GB2000 Components 5 3 2 1 4 6 7 1 . Lamp Fixture — Made of heat resistant poly ester balloon, with a diameter of 35.5 inches (902 mm) and two 1000 watt metal halide lamps .
GB2000 CSA B ALLOON LIGHT• OPERA TION AND P ARTS MANU AL — REV . #1 (02/25/14)— P A GE 19 PREP ARA TION 1 . Place the light to wer in an area free of dirt and debr is with enough clearance as not to interf ere with any ov erhead obstructions.
P A GE 20 —GB2000 BALLOON LIGHT• OPERA TION AND P AR TS MANU AL — REV . #1 (02/25/14) LAMP AD APTER PLA TE MOUNTING INST ALLA TION 1 . Remove the adapter plate kit hardw are from its container .
GB2000 CSA B ALLOON LIGHT• OPERA TION AND P ARTS MANU AL — REV . #1 (02/25/14)— P A GE 21 SETUP Figure 7. Adapter Plate Mounting Installation VIEW F ROM B A CK SIDE BOL T (4) FLA T W ASHER (8) L.
P A GE 22 —GB2000 BALLOON LIGHT• OPERA TION AND P AR TS MANU AL — REV . #1 (02/25/14) JUNCTION BO X MOUNTING 1 . Secure the junction box (Figure 8) to the adapter plate using the supplied bolts (2), lock w asher (2), and flat washer (2). Tighten mounting bolts securely .
GB2000 CSA B ALLOON LIGHT• OPERA TION AND P ARTS MANU AL — REV . #1 (02/25/14)— P A GE 23 SETUP Use Figure 10 as a ref erence when deter mining orientation of lamps and receptacles on T -Bar . Figure 10 is looking at the light tower from the rear to the front.
P A GE 24 —GB2000 BALLOON LIGHT• OPERA TION AND P AR TS MANU AL — REV . #1 (02/25/14) LAMP CABLE CONNECTIONS On the T -Bar (Figure 11) there are f our power receptacles J1, J2, J3 and J4. These receptacles provide A C power to the e xisting rectangular lamps.
GB2000 CSA B ALLOON LIGHT• OPERA TION AND P ARTS MANU AL — REV . #1 (02/25/14)— P A GE 25 LAMP LIGHTING OPTIONS T able 3. Figure 12. Option 2 Lighting Configuration LAMP 4 TOP LAMP 2 TOP 1 2 3 .
P A GE 26 —GB2000 BALLOON LIGHT• OPERA TION AND P AR TS MANU AL — REV . #1 (02/25/14) LAMP LIGHTING OPTIONS Figure 13. Option 3 Lighting Configuration CB1 CB2 CB3 CB4 ON ON ON ON ON ON CB1 CB2 .
GB2000 CSA B ALLOON LIGHT• OPERA TION AND P ARTS MANU AL — REV . #1 (02/25/14)— P A GE 27 LAMP LIGHTING OPTIONS Figure 14. Option 4 Lighting Configuration LAMP 4 TOP LAMP 2 TOP 4 Lamps Installe.
P A GE 28 —GB2000 BALLOON LIGHT• OPERA TION AND P AR TS MANU AL — REV . #1 (02/25/14) LAMP LIGHTING OPTIONS Figure 15. Option 5 Lighting Configuration LAMP 4 TOP LAMP 2 TOP 1 2 3 4 GB2000 NOT U.
GB2000 CSA B ALLOON LIGHT• OPERA TION AND P ARTS MANU AL — REV . #1 (02/25/14)— P A GE 29 LAMP LIGHTING OPTIONS Figure 16. Option 6 Lighting Configuration LAMP 4 TOP LAMP 2 TOP 1 2 3 4 GB2000 C.
P A GE 30 —GB2000 BALLOON LIGHT• OPERA TION AND P AR TS MANU AL — REV . #1 (02/25/14) OPERA TION REMO VING BALLOON PR O TECTIVE CO VER 1 . Expose the balloon by unsnapping the buttons and unzipping the protectiv e cov er as shown in Figure 17. Figure 17.
GB2000 CSA B ALLOON LIGHT• OPERA TION AND P ARTS MANU AL — REV . #1 (02/25/14)— P A GE 31 OPERA TION INFLA TING BALLOON AND TURNING ON LAMPS (ML T ONL Y) 1 . On ML T ser ies light towers , reconnect the 4-pin pow er cable (Figure 20) to the 120 V A C twist-lock receptacle on the front panel of the generator .
P A GE 32 —GB2000 BALLOON LIGHT• OPERA TION AND P AR TS MANU AL — REV . #1 (02/25/14) MAINTENANCE REPLA CING LAMP 1 . Unzip the zipper at the bottom of the balloon and roll the balloon up to e xpose the lamp . See Figure 22. Figure 22. Exposing Balloon 2 .
GB2000 CSA B ALLOON LIGHT• OPERA TION AND P ARTS MANU AL — REV . #1 (02/25/14)— P A GE 33 MAINTENANCE 6 . Secure lamp holder on top of the lamp. 7 . Reinstall lamp guard. 8 . Pull down balloon and zip the bottom zipper to cov er lamp . REPLA CING BALLOON 1 .
P A GE 34 —GB2000 BALLOON LIGHT• OPERA TION AND P AR TS MANU AL — REV . #1 (02/25/14) MAINTENANCE T able 4. T r oubleshooting SYMPT OM POSSIBLE PROBLEM SOLUTION Lamp does not light. Is plug disconnected? Plug in correctly . Is generator pow er switched off? T ur n on s witch.
GB2000 CSA B ALLOON LIGHT• OPERA TION AND P ARTS MANU AL — REV . #1 (02/25/14)— P A GE 35 WIRING DIAGRAM LAMP BOTTOM WHITE WHITE WHITE RED BLUE RELA Y DC F AN MOTOR RED RED BLACK BLACK WHITE WHI.
P A GE 36 —GB2000 BALLOON LIGHT• OPERA TION AND P AR TS MANU AL — REV . #1 (02/25/14) EXPLANA TION OF CODE IN REMARKS COLUMN The f ollowing section e xplains the diff erent symbols and remarks used in the Parts section of this manual. Use the help numbers f ound on the back page of the man ual if there are any questions .
GB2000 CSA B ALLOON LIGHT• OPERA TION AND P ARTS MANU AL — REV . #1 (02/25/14)— P A GE 37 SUGGESTED SP ARE P AR TS GB2000 B ALLOON LIGHT 1 to 3 units Qty . P/N Description 2............E000127300 ......... LAMP 2............A100079601 ......... BALLOON CO VER CP 3.
P A GE 38 —GB2000 BALLOON LIGHT• OPERA TION AND P ARTS MANU AL — REV . #1 (02/25/14) NAMEPLA TE AND DECALS N E V E R d isc o n n ec t t h e co n n ec t o r w h en p o w er is ap p l ie d . Th e p o s si b il i t y ex ist s of Electrical shock or equipment damage.
GB2000 CSA B ALLOON LIGHT• OPERA TION AND P ARTS MANU AL — REV . #1 (02/25/14)— P A GE 39 NAMEPLA TE AND DECALS N O. P ART NO . P ART NAME QTY . REMARKS 1 A400290900 DECAL; CA UTION, LAMP INFORM.
P A GE 40 —GB2000 BALLOON LIGHT• OPERA TION AND P ARTS MANU AL — REV . #1 (02/25/14) ELECTRICAL ASSY . 1 2 3 4 5 6 7 8 9 10 11 12 12 13 16 17 17 17 19 18 20 16 21 22 23 23 24 24 25 20 26 27 28 2.
GB2000 CSA B ALLOON LIGHT• OPERA TION AND P ARTS MANU AL — REV . #1 (02/25/14)— P A GE 41 ELECTRICAL ASSY . N O. P ART NO . P ART NAME QTY . REMARKS 1 E000127300 LAMP 2 2 A100100002 LAMP GU ARD .
P A GE 42 —GB2000 BALLOON LIGHT• OPERA TION AND P ARTS MANU AL — REV . #1 (02/25/14) ELECTRICAL ASSY . (CONTINUED) 1 2 3 4 5 6 7 8 9 10 11 12 12 13 16 17 17 17 19 18 20 16 21 22 23 23 24 24 25 2.
GB2000 CSA B ALLOON LIGHT• OPERA TION AND P ARTS MANU AL — REV . #1 (02/25/14)— P A GE 43 ELECTRICAL ASSY . (CONTINUED) N O. P ART NO . P ART NAME QTY .
P A GE 44 —GB2000 BALLOON LIGHT• OPERA TION AND P ARTS MANU AL — REV . #1 (02/25/14) BRACKET AND J-BOX ASSY ..
GB2000 CSA B ALLOON LIGHT• OPERA TION AND P ARTS MANU AL — REV . #1 (02/25/14)— P A GE 45 BRACKET AND J-BOX ASSY . N O. P ART NO . P ART NAME QTY . REMARKS 1 A200102501 BO X (RELA Y) 1 2 A300282800 R UBBER CAP 1 3 A300284400 PLA TE CAP 1 4 0033304000 CAP NUT (M4) 8 5 0024304008 SCREW TR USS (M4x8) 2 6 0023305015 SCREW & W ASHER (M4x12) .
P A GE 46 —GB2000 BALLOON LIGHT• OPERA TION AND P ARTS MANU AL — REV . #1 (02/25/14) TERMS AND CONDITIONS OF SALE — P AR TS P A YMENT TERMS T erms of payment for par ts are net 30 d ay s. FREIGHT POLIC Y All par ts order s will be shipp ed colle ct or prepaid wi th the charg es added to t he invoice.
GB2000 CSA B ALLOON LIGHT• OPERA TION AND P ARTS MANU AL — REV . #1 (02/25/14)— P A GE 47 NOTES.
OPERA TION AND P AR TS MANUAL Y our Local Dealer is: HERE’S HOW TO GET HELP PLEASE HA VE THE MODEL AND SERIAL NUMBER ON-HAND WHEN CALLING © COPYRIGHT 2014, MUL TIQUIP INC. Multiquip Inc , the MQ logo are registered trademarks of Multiquip Inc. and ma y not be used, reproduced, or altered without written permission.
Een belangrijk punt na aankoop van elk apparaat Multiquip GB2000 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Multiquip GB2000 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Multiquip GB2000 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Multiquip GB2000 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Multiquip GB2000 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Multiquip GB2000 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Multiquip GB2000 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Multiquip GB2000 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.