Gebruiksaanwijzing /service van het product GEM-X255 van de fabrikant NAPCO
Ga naar pagina of 40
1 OPERA TING GUIDE for the GEM-X255 Security System © NAPCO 2001 DESIGN PATS. PENDING ARMED COMPUTERIZED SECURITY SYSTEM STAT US GEMINI A 1 2 3 B 4 5 6 C 7 8 9 0 E F G J SYSTEM ARMED 01/01/00 12:00 AM GEM-X255_OI273_USER.
2 The GEM-RP1C Ae2 is a “ smart ” user-friendly, m enu-driven keypad designed for your N apco GEM-X255 control panel. The key pad is interactive. Its alphanumeric screen will not only display the status of your system, but will also give you step-by-step instructi ons to guide you through all operations.
3 TABLE OF CONTENTS TABLE OF CONTENTS Section Page KEY PAD CON TROLS & IND ICATO RS ................... ............ ............. 4 SETTING THE ALARM (ARMING) WHEN LEAVING . ..... ..... ...... ..... . 6 PRO TECTI NG Y OU RSEL F WHIL E ON THE PRE MISES .
4 KEYPAD CONTROLS & INDICATORS ARMED COMPU TERIZE D SEC URITY SY STEM STATUS GEMINI A 1 2 3 B 4 5 6 C 7 8 9 0 E F G J SYS TEM AR MED 01/01/00 12:00 AM 1 2 3 4 5 6 7 12 8 9 10 11 GEM-X255_OI273_USER.
5 KEYPAD CONTROLS & INDICATORS Window. Displays system status messages, zone descriptions, etc. STATUS Light. Lights (green) to indicate that the system is ready for arming. If a zone is not secured the light will be off and the zone will d ispla y in t he wind ow.
6 SETTING THE ALARM (ARM ING) WHEN LEAVING Arming the Sys tem 1 Check the key pad . The green ST ATUS light m ust be on in order to arm. If the green light is off, “ZONES FAULT ED” w ill display in the window followed by the number and description of ea ch faulted zone.
7 SETTING THE ALARM (ARM ING) WHEN LEAVING Sy stem Troubl e If you attempt to arm with a “SYSTEM TROUBLE” display al ternating with an indicated trouble code (e .g. “E02-00 ” (low batte ry); see SYSTEM TRO UBLE ERROR CODES), a 3- second tone will sound at t he key pad.
8 Bypassing Interi or Zones I nterior Zones, w hen bypassed, allow free move ment w ithin the home w hile the protec tion of armed perimeter zones i s maintained. To bypass Interior Zones, pres s E and enter your User Code followed by D . Your system m ay have provisions for two gro ups of In terior Zones.
9 PROTECTING YOURSELF WHILE ON THE PREMISES Easy Exit (Optional - Easy Exit programmed? ! YES ! NO) Your system may have been programmed for Easy Exit, which a llows a user to exit the premises while the system is armed.
10 Disarming the Sy stem 1 Enter your premise s through the Entry/Exit door. T he keypad will sound a s teady tone to remind you to disarm the system be f or e you r Ent r y De l ay t i me ex p ir e s. 2 Enter y our User Code an d press D . The red ARMED light will go out, indicating that the system has been disarme d.
11 FIRE PROTECTION (Applicable only where local ordinanc e permits use of this alarm cont rol panel for fi re protection.) Fire-Zone Alarm If a fire is detected, “FIRE ALARM” will be displayed and the keypad sounder will pulse.
12 FIRE PROTECTION Preparing a Fire Escape Plan Even with the mo st advanced f ire alarm system, adequate protection requires an escape plan. To prepare your plan, draw floor plans of your buildin g. (Space is provided on the nex t page.) Show two exits - a front or back door and a window from each room.
13 FIRE PROTECTION Floorplan Draw a plan of y our premis es in the spac e provided below. Floorplan GEM-X255_OI273_USER.pub page 13 Tuesday, September 10, 2002 13:14.
14 FIRE PROTECTION Although a fire alarm system may be of a reliable and state-of- the-art design, neither it nor its peripheral detection devices can offer guaranteed protection against fire.
15 KEYPAD FUNCTIONS The keypad can provide access to a wide assortment of utility func tions. The functi ons are displayed in a prompting “YES/NO” format. 1 To enter the F unction Menu, pres s A . • In all UL-listed or high-security installations, a valid User Code must firs t be ent ered followed by A .
16 A ctivate Bell Test? Activates the alarm (while disarmed) for about 2 seconds and pe rforms a battery test. If the alarm does not s ound, call for serv ice. • If the batte ry is low, a “LOW BATTERY E02-00 SERVICE” will appear in the display indicating a low battery condition.
17 KEYPAD FUNCTIONS Res et System Tr ouble? System troubles display and sound at the keypad. Correcti ng the trouble will clear most indications , howev er the foll owing error codes w ill require manual reset: E13; E 19; E20 and E 22. (See S YSTEM TROU BLE ERROR CODES for a description of error codes.
18 KEYPAD FUNCTIONS Activate Te lephone Test? (Telephone Test programm ed? ! YES ! NO). Sends a communicator test to the cent ral station. A communication failure will be indicated at the keypad by a system trouble “E03 -FAIL TO COMM” display.
19 KEYPAD FUNCTIONS Activate Program? Activates the Program Mode fr om Keypad No. 1. Note: This feature is di sabled while arme d . (See PROGRA MMING USER C ODES) Activa te Dow nload? Fo r installer's use only. If accidentally enabled, press C to exit.
20 Your alarm specialist may have programm ed your syste m to be monitored by a central station. The bu ilt- in dig ital co mmun ica tor can transmit emergency signals and status reports to the central station 24 hours a day. Communicator Features Abort Delay.
21 ADVANCED FEATURES Security By pass/Unby pass (Security Bypass programmed? ! YES ! NO). In high-security applications, zones may be bypassed (or unbypa ssed) only if a valid code is entered first, as follows: 1. Enter a User Code valid for bypass, then press B .
22 PROGRAMMING (OPTIONAL) Enter the User Prog ram Mod e 1 Enter your User Code, then press A to enter the Func tion Mode. 2 Answer NO ( F ) until “ACTIVATE PROGRAM Y/ N” is displayed , then press YES ( E ) “ENTER USER CODE” will display indicating that the system is ready for User Code programm ing.
23 PROGRAMMING (OPTIONAL) Reviewing a Programmed User Code To review an ex isting User Code, enter the 2-digit user number and the corresponding User Code w ill displ ay. Exiti ng the User Program Mode When you have completed pro gramming or erasing User Codes, press C to exit the User Program Mode.
24 PROGRAMMING (OPTIONAL) Enter the User Prog ram Mode 1 Enter your User Code, then press A to enter the Functi on Mode. 2 Answer NO (press F ) until “ACTI VATE PROGRAM Y/N” is dis played , then press YES ( E ). “ ENTER USER CODE” will display, press NEXT ( E ) and the keypad wi ll display the Zone 1 Description .
25 PROGRAMMING (OPTIONAL) Enter the User Prog ram Mod e 1 Enter your User Code, then press A to enter the Func tion Mode. 2 Answ er NO (press F ) until “ACTI VATE PROGRAM Y/N” is displayed , then press YES ( E ). “ENTER USER CODE” will display, press NEXT ( E ) until the keypad display s the “Enter Date” screen.
26 KEYPAD MESSAGES The keypad can display th e following functional messages. Other diag nostic messages are available for the installer or servicer. Should any unfamiliar message appear, call your dealer for service. All zones op erating; system can be armed.
27 KEYPAD MESSAGES Alarm condi tion, followed by zone descript ion(s). “ALARM” and zones will display after syste m is disarmed. N ote zones, then press C to clea r key pad. (With pu lsing sounder.) T rouble condi tion on a Fire Zone. Press C to s ilence sounder.
28 KEYPAD MESSAGES The system is in the proce ss of reporting a ca ncel sig nal to central s tation which will cancel the ala rm which it has jus t reported. The system has rece ived an ack nowledgment from c entral st ation of the cancellat ion of the alarm s ignal.
29 GLOSSARY Following are brief desc riptions of terms and feat ures used herein t hat may be unfamil iar to you. Some of the features are programmable options that may or may not apply to your particul ar system. Abort Delay - A delay perio d that allows the control panel to be reset, thus aborting a report to a central station.
30 GLOSSARY INTERIOR Button - Bypasses Interior Zones on arming (see Zone s - Interior Zones). Instant Protection - Arming without entry delay using the F button while remaining on the premises. Keypad - Puts control-panel functions at your fingertips.
31 GLOSSARY Zones - Independe nt circuits that protect specific areas of the premises: Auto-B ypass Zone : A zone t hat will be autom aticall y bypassed from the protectio n system if it is in trouble (faulty) when the system is armed. Burglary Zone: Detects in trusio n.
32 SYSTEM TROUBLE ERROR CODES Your control panel i s capable of det ecting a variety of trouble s that may affect system perfo rmance. I n the unlikely event that a problem s hould occur, the SYS T BL (system t rouble) icon will display on the lef t side of keypad window along with one or more o f the following error codes .
33 SYSTEM TROUBLE ERROR CODES Trouble Indication System Trouble Condition Action E04- NNN Wirele ss Transmitte r Supervisory Failure A problem has been de tected with a wireless trans mitt er. Call installing c ompany for service E05- NNN Wirele ss Transmi tter Low Battery The battery in a wireless tra nsmitte r is low and should be replac ed.
34 SYSTEM TROUBLE ERROR CODES Trouble Indication System Trouble Condition Action E10-NN Keypad Response Fail ure Call installing c ompany for service. E11-NN Keypad Tamper A keypad has been remove d from the wall. Call insta lling company for serv ice if problem cannot b e repaired.
35 SYSTEM TROUBLE ERROR CODES Trouble Indication System Trouble Condition Action E19-00 User Program Memory Call installing c ompany for service. E20-00 Dealer Program Memory Call installing c ompany for service. E21-00 System Shutdown Call installing c ompany for service.
36 SYSTEM TROUBLE ERROR CODES Trouble Indication System Trouble Condition Action E40-00 RF Self Test Failure A wireless motion se nsor on the zon e indicated has f ailed its automatic self test routine. Call installing c ompany for service. E41- NNN Fire Troubl e A problem has be en detected on the Fire zone indic ated.
37 TROUBLESHOOTING What do I do if... For more info... I try to arm my sy stem but the keypad just displays “ZONES NOT NORMAL” and “CAN’T ARM SYSTEM” and beeps at me. If the green STATUS light is off, a zone is open. Fin d and secure the open windo w or door.
38 NOTES GEM-X255_OI273_USER.pub page 38 Tuesday, September 10, 2002 13:14.
39 NOTES GEM-X255_OI273_USER.pub page 39 Tuesday, September 10, 2002 13:14.
40 NAPCO LIMITED WARRANTY NAPCO SECURITY SYSTEMS, INC. (NAPCO) warrant s its products to be free from manufacturing defects in materials a nd workmanship for thir ty-six months foll owing the da te of manufacture.
Een belangrijk punt na aankoop van elk apparaat NAPCO GEM-X255 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen NAPCO GEM-X255 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens NAPCO GEM-X255 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding NAPCO GEM-X255 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over NAPCO GEM-X255 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van NAPCO GEM-X255 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de NAPCO GEM-X255 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met NAPCO GEM-X255 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.