WHA T T O DO IF Y OU SMELL GAS WARNINGS & SAFETY PRECA UTIONS.
W ARNING • Do not burn wood or other materials in this fireplace. • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Keep young children and animals away when the fireplace is hot.
4 W415-0484 / A / 07.26.06 ALL SPECIFICA TIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL L TD. PA TENTS U.S. 5.303.693.801 - CAN. 2.073.41 1, 2.082.915.
5 W415-0484 / A / 07.23.06 THIS GAS FIREPLACE SHOULD BE INST ALLED AND SER V - ICED BY A QUALIFIED INST ALLER to conform with local codes. In absence of local codes, install the B3 6DF to the current National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes.
6 W415-0484 / A / 07.26.06 Use only Wolf S teel, Simpson Dura-V ent, Selkirk Direct T emp or American Metal Amerivent venting components. For Simpson Dura-V ent, Selkirk Direct T emp and American Metal Amerivent, follow the installation procedure provided with the venting components.
7 W415-0484 / A / 07.23.06 * * * * * Recommended to prevent condensation on windows and thermal breakage ** ** ** ** * * It is recommended to use a hea t shield and to maximize the distance to vinyl c lad sof fits . *** *** *** *** ** * The periscope GD-201 requir es a minimum 18 inc hes clear ance from an inside corner .
8 W415-0484 / A / 07.26.06 Use the GD401 periscope kit to locate the air termination above grade. The periscope must be installed so that when final grading is completed, the bottom air slot is located a minimum of 12 inches above grade. The maximum allow- able vent length depends on the fireplace, as illustrated.
9 W415-0484 / A / 07.23.06 VERTICAL TERMINA TION HORIZONT AL TERMINA TION V ertical rise is equal to or greater than the horizontal run Horizontal run + verti- cal rise to maximum of 40 feet Vertical .
10 W415-0484 / A / 07.26.06 ELBOW VENT LENGTH V AL UES DEFINITIONS HORIZONT AL TERMIN A TION REQUIRED VERTICAL RISE IN FEET (V T ) CALCULA TED HORIZONT AL VENT RUN PLUS OFFSETS IN FEET (H T ) FIGURE 5.
11 W415-0484 / A / 07.23.06 V 1 HORIZONT AL TERMINA TION See graph to determine the re- quired vertical rise V T for the re- quired horizontal run H T . For vent configurations requiring more than one 45º and 90° elbow the following formulas apply: Formula 1: H T < 4.
12 W415-0484 / A / 07.26.06 VERTICAL TERMINA TION Example 3: V 1 =5 f t V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 =3 f t H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03(one 45º elbow + three 90º elbows - 135º) = .03(45+90+90+90-135)=5.
13 W415-0484 / A / 07.23.06 H 1 VERTICAL TERMINA TION For vent configurations requiring more than one 45º and one 90° elbow , the following formulas apply: F o r mula 1: H T < 3V T F o r mula 2: .
14 W415-0484 / A / 07.26.06 This application occurs when venting through a roof. Installation kits for various roof pitches are available from your Napo- leon dealer .
15 W415-0484 / A / 07.23.06 INNER FLEX LINER OUTER FLEX LINER INNER SLEEVE HIGH TEMPERA TURE SEALANT AIR TERMINAL CONNECTOR FIGURE 18 A VENT SHIELD MUST BE USED IF THE W ALL TERMINAL IS INST ALLED ON COMBUSTIBLE, EXTERIOR SURF ACES. 1. Cut or frame a hole in an exterior wall with a minimum oval or rectangle opening of 10½"w x 1 1 ½"h.
16 W415-0484 / A / 07.26.06 V ertical terminations may display a very active flame. As this appearance is not desirable, the vent exit must be restricted using restrictor plate, W500-0205. This reduces the velocity of the exhaust gases, slowing down the flame pattern and creating a more traditional appearance.
17 W415-0484 / A / 07.23.06 This appliance may be installed as an OEM (Original Equipment Manufacturer) installation in a manufactured home or mobile home and must be installed in accordance with the .
18 W415-0484 / A / 07.26.06 NAILING TA B 1) Attach the nailing tabs to the corner posts using the 2 sheet metal screws supplied. Secure through the centre of the top and bottom slots in the nailing tab and then through the existing holes in the corner posts.
19 W415-0484 / A / 07.23.06 A C B The upper louvres must be removed to allow the door to be opened or closed. T o access the lower door latch, open the valve control door . Release the top and bottom door latches, located at the right side of the door .
20 W415-0484 / A / 07.26.06 PHAZER TM logs and glowing embers exclusive to Napoleon Fire- places, provide a unique and realistic glowing effect that is different in every inst allation. T ake the time to carefully po- sition the glowing embers for a maximum glowing effect.
21 W415-0484 / A / 07.23.06 INST ALLA TION TO BE DONE BY A QUALIFIED IN- ST ALLER and must be electri- cally connected and grounded in accord- ance with local codes.
22 W415-0484 / A / 07.26.06 ELECTRICAL INST ALLA TION TO BE DONE BY A QUALI- FIED INST ALLER and must be connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 C ANADIAN ELECTRICAL CODE in Canada or the ANSI/NFP A 70 N A TIONAL ELECTRICAL CODE in the United S tates.
23 W415-0484 / A / 07.23.06 • Turn off all gas to the fireplace. • Open windows. • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbour's phone.
24 W415-0484 / A / 07.26.06 Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow . Air shutters have been factory set open according to the chart below: These settings are for the maximum horizontal vent run.
25 W415-0484 / A / 07.23.06 COMMON REPLA CEMENT P ARTS: 37* W175-0166 5" COUPLER 37* W175-0002 8" COUPLER 38 L36K LOUVRE KIT - UPPER & LOWER - BLACK 38 L36PB LOUVRE ASSEMBL Y - POLISHED BRASS 38 L36AB LOUVRE ASSEMBL Y - ANTIQUE BRASS 38 L36SS LOUVRE ASSEMBL Y - BRUSHED S T AINLESS STEEL 39* W573-0007 10.
26 W415-0484 / A / 07.26.06 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.
27 W415-0484 / A / 07.23.06 Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button ignitor . - check if the push button ignitor needs tightening. - replace the wire if the wire insulation is broken or frayed.
28 W415-0484 / A / 07.26.06 Pilot goes out while standing; Main burner is in 'OFF' position. Gas piping is undersized. - turn on all gas appliances and see if pilot flame flutters, dimin- ishes or extinguishes, especially when main burner ignites.
29 W415-0484 / A / 07.23.06 W olf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Deale.
30 W415-0484 / A / 07.26.06 NO TES.
Een belangrijk punt na aankoop van elk apparaat Napoleon B36DFP (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Napoleon B36DFP heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Napoleon B36DFP vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Napoleon B36DFP leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Napoleon B36DFP krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Napoleon B36DFP bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Napoleon B36DFP kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Napoleon B36DFP . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.