Gebruiksaanwijzing /service van het product 1100L van de fabrikant Napoleon Fireplaces
Ga naar pagina of 20
1 W415-0512 / B / 1 1.15.05 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.
2 W415-0512 / B / 1 1.15.05 PG 2 - 4 INTRODUCTION Warranty General Information Care of Plated & Enamelled Parts Care of Glass 5- 6 INST AL LA TION Installing the Legs Alcove Installation S tove In.
3 W415-0512 / B / 1 1.15.05 NAPOLEON products are manufactured under the strict Standard of the World Recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0512 / B / 1 1.15.05 Except for their different depths, models 1 100, 1 150, 1400, 1900 and the fireplace inserts 1 101 and 1401 are identical and use the same burning principles. They were specifi- cally designed over many months of research to meet the 1990 U.
5 W415-0512 / B / 1 1.15.05 To avoid being damaged during shipping, the stove has been bolted to the pallet and must be unbolted before the stove can be installed. 1. Remove the 4 nuts and washers from the underside of the pallet. 2. Lift the stove up and away from the pallet to clear the threaded studs sticking through the pallet.
6 W415-0512 / B / 1 1.15.05 PEDESTAL BASE 4.5" PEDESTAL BASE FLOOR AREA BELOW STOVE A" B" A (in.) B(in.) 1 100 8 5/8" 9 3/4" 1400 1 1 1/8" 9 3/4" 1900 14 7/8" 9.
7 W415-0512 / B / 1 1.15.05 It must be installed be- tween ceiling joists, with radiation shield and roof flashing, so that the structural strength, insulation and waterproof quali- ties of the home are not lessened. Seal with silicone to maintain a vapour barrier at the chimney and outside air pipe penetrations.
8 W415-0512 / B / 1 1.15.05 In the United States: While it is not required, it is rec- ommended that a chimney liner be installed that is con- tinuous from the insert to the top of the chimney , particu- larly when the insert is installed in a basement.
9 W415-0512 / B / 1 1.15.05 3. The access panel can be removed by taking out the 8 #10 self taping screws. A 5/16" nut driver will be required to complete this job.
10 W415-0512 / B / 1 1.15.05 1 100/1 100C/ 1101 1400/1400L 1401 1900 1 100L/1 150 4-#1 4-#1 4-#1 4-#1 4-#7 * 2-#4 2-#4 2-#4 2-#4 2-#2 8-#1 8-#1 12-#1 12-#1 12-#7 * 2-#3 2-#3 2-#3 2-#4 (notched) 2-#10 .
11 W415-0512 / B / 1 1.15.05 With stove and chimney installation completed, move the bricks into place by working as illustrated for your unit on page 10. 1. Install two or three courses of brick on both sides of the unit. Install two courses on the back wall.
12 W415-0512 / B / 1 1.15.05 ASH W ELL COVER ROTATE TO CLOSE: FOLDING HANDLE REAR ROTATE PULL AND TO O PEN: Y ou can now add larger pieces of wood and operate the stove normally . Once the stove/insert is entirely hot, it will burn very efficiently with little smoke from the chimney .
13 W415-0512 / B / 1 1.15.05 A properly installed Napoleon unit should not smoke. If yours does, check the following: Has the chimney had time to get hot? Is the smoke passage blocked anywhere in the stove, chimney connector or chimney? Is the room too airtight and the air intake not connected to the outside? Try with a window partly open.
14 W415-0512 / B / 1 1.15.05 Burn only dry , clean unpainted wood that has been seasoned. It produces more heat and less soot or creosote. Freshly cut wood contains about 50% moisture while after proper sea- soning only about 20% of the water remains.
15 W415-0512 / B / 1 1.15.05 # P AR T NO . DESCRIPTION 1 W325-0002 SPRING HANDLE - SMALL 2 W325-0007 SPRING HANDLE - LARGE 3* W090-0001 BRICK - # 1 4* W090-0002 BRICK - # 2 5* W090-0004 BRICK - # 4 LE.
16 W415-0512 / B / 1 1.15.05 6 5 GS200-G ORNAMENT A L TRIVET 6 6 EP62-1 V ARIABLE SPEED BLOWER 67* W500-0064 FRESH AIR COVER PLA TE 68* 1 1 1 K T OUTSIDE AIR KIT 69* W470-0002 ENAMEL TOUCH UP & BR.
17 W415-0512 / B / 1 1.15.05 59 15 16 18 17 19 16 57 2 32 12 10 14 30 33 74 31 44 84 83 73 72 76 63 64 Z.P. Ins. ClassB 115V 60Hz 46W EM3030L-167 zr-2 073 SEL 81 66 1 46 77 40 38 39 58 65 55 56 48 49 .
18 W415-0512 / B / 1 1.15.05 W olf Steel Fireplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Deale.
19 W415-0512 / B / 1 1.15.05 NO TES.
20 W415-0512 / B / 1 1.15.05 NO TES.
Een belangrijk punt na aankoop van elk apparaat Napoleon Fireplaces 1100L (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Napoleon Fireplaces 1100L heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Napoleon Fireplaces 1100L vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Napoleon Fireplaces 1100L leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Napoleon Fireplaces 1100L krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Napoleon Fireplaces 1100L bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Napoleon Fireplaces 1100L kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Napoleon Fireplaces 1100L . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.