1 W415-0612 / C / 01.25.08 INST ALLA TION AND OPERA TION INSTRUCTIONS W olf Steel Ltd., 24 Napoleon Rd ., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 ww w .
2 W415-0612 / C / 01.25.08 • Do not burn wood or other materials in this fi replace. • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Supervise young children when they are in the same room as the fi replace.
3 W415-0612 / C / 01.25.08 NAPOLEON® products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Cer tifi cate. NAPOLEON® products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0612 / C / 01.25.08 FOR YOUR SATISFACTION, THIS FIR EPL ACE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY! Minimum inlet gas supply pressure is 4.5 inches water column for natural gas and 1 1 inches water column for propane. Maximum inlet gas pressure is 7 inches water column for natural gas and 13 inches water column for propane.
5 W415-0612 / C / 01.25.08 33 1 / 8 ” 4” DIA. 7” DIA. 13” 15 3 / 8 ” 12” 26 3 / 8 ” 34 1 / 8 ” 34 1 / 8 ” 33 7 / 8 ” 9 1 / 2 ” 5” 2 1 / 2 ” 1 3 / 4 ” GAS LINE ACCESS ELECTRICAL ACCESS 4” DIA.
6 W415-0612 / C / 01.25.08 For safe and proper operation of the fi replace follow the venting instruction exactly . Deviation from the minimum or the maximum vertical vent length can create dif fi culty in burner start-up and/or carboning.
7 W415-0612 / C / 01.25.08 Use the GD201 periscope kit to locate the air termination above grade. The periscope must be installed so that when fi nal grading is completed, the bottom air slot is located a minimum of 12" above grade. The maximum allowable vent length is 10 ft.
8 W415-0612 / C / 01.25.08 FIGURE 6 MINIMUM AIR TERMINAL L OCA TION CLEARANCES.
9 W415-0612 / C / 01.25.08 VENTING APPLICA TION FL O W CHART FIREPLACE VENT EXIT REAR EXIT TOP EXIT Horizontal T ermination V ertical Termination V ertical Termination V ertical rise is equal to or gr.
10 W415-0612 / C / 01.25.08 90° 90° 90° H 1 V 2 H 2 V 1 n fi guration (only one 90° elbow) Simple venting con fi guration (only one 90° elbow) See graph to determine the required vertical rise V T for the required horizontal run H T .
11 W415-0612 / C / 01.25.08 H 2 H 4 V 2 90° H 3 H 1 V 1 90° 90° H 2 H 1 V 1 Simple venting con fi guration (only one 90° elbow) Example 2: V 1 = V T = 6 ft H 1 = 3 ft H 2 = 5 ft H R = H 1 + H 2 = 3 + 5 = 8 ft H O = .03(two 90° elbows - 90°) = .
12 W415-0612 / C / 01.25.08 See graph to determine the required vertical rise V T for the required horizontal run H T For vent con fi gurations requiring more than two 90° elbows the following formu.
13 W415-0612 / C / 01.25.08 H 1 H 2 V 1 V 2 90° 45° 90° 90° Simple venting con fi guration (only two 90° elbows) Example 5: V 1 = 4 ft V 2 = 1.5 ft V T = V 1 + V 2 = 4 + 1.5 = 5.5 ft H 1 = 2 ft H 2 = 1 ft H 3 = 1 ft H 4 = 1.5 ft H R = H 1 + H 2 + H 3 + H 4 = 2 + 1 + 1 + 1.
14 W415-0612 / C / 01.25.08 The shaded area within the lines represents acceptable values for H T and V T . Example 6: V 1 = 3 ft V 2 = 6 ft V 3 = 8 ft V T = V 1 + V 2 + V 3 = 3 + 6 + 8 = 17 ft H 1 = 2 ft H 2 = 2.5 ft H R = H 1 + H 2 = 2 + 2.5 = 4.5 ft H O = .
15 W415-0612 / C / 01.25.08 The shaded area within the lines represents acceptable values for H T and V T . For vent con fi gurations requiring more than two 90° elbow (top exit) or one 90° elbow (.
16 W415-0612 / C / 01.25.08 In order to convert the venting con fi guration from a rear exit to a top exit , remove the components as illustrated: When reinstalling in the alternate position: Check gaskets for tears, replace if necessary to ensure a proper seal.
17 W415-0612 / C / 01.25.08 HORIZONT AL INST ALLA TION VERTICAL INST ALLA TION INST ALLA TION WALL AND CEILING PR O TECTION FIGURE 19 This application occurs when venting through an exterior wall.
18 W415-0612 / C / 01.25.08 Use only approved fl exible vent pipe kits marked: “Wolf Steel Approved V enting” as identi fi ed by the stamp only on the 7” fl exible vent pipe.
19 W415-0612 / C / 01.25.08 CAULKING #10x2" SCREWS HIGH TEMPERA TURE SEALANT #8 x 1/2" SCREWS 7" RIGID VENT PIPE 2" OVERLAP 4" RIGID VENT PIPE ATTE NTION-CH AUD CAUTI ON - H OT FIGURE 29 1.
20 W415-0612 / C / 01.25.08 REAR VENT APPLICA TION: Attach 4" and 7" elbows to the fi replace. Secure with 3 screws and seal the joints and screw heads using high temperature sealant. Proceed to step 1 below . TOP VENT APPLICA TION: 1. Move the fi replace into position.
21 W415-0612 / C / 01.25.08 FIGURE 35 GAS INST ALLA TION This Mobile/Manufactured Home Listed appliance comes factory equipped with a means to secure the unit. The fi replace is equipped with two 1/4" diameter holes located in the front left and right corners of the base.
22 W415-0612 / C / 01.25.08 REAR VENT T OP VENT 13 1 / 4 ” 22 1 / 4 ” 22 1 / 4 ” 2 " 4 " 4 " 6 " 2 " SIDE WA L L PROTRUSION INSIDE CHASE OUTSIDE CHASE 13 1 / 4 ” 22 1 .
23 W415-0612 / C / 01.25.08 MINIMUM MANTEL AND ENCL OSURE CLEARANCES Mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the clearance needed. Combustible materials must be installed fl ush with the front of the fi replace but must not cover any of the black face-area of the fi replace.
24 W415-0612 / C / 01.25.08 FR ONT F A CING AND INSET KIT INST ALLA TION 4. Clip the keystone 6 over the band of material and centre on the magnet. 5. While angling the bottom inset, insert the side tabs on the bottom inset 4 behind the side edges of the control panel opening.
25 W415-0612 / C / 01.25.08 FIGURE 54 4. Place the thermal disk assembly onto the stud located at the lower left of the fi rebox and behind the support bracket.
26 W415-0612 / C / 01.25.08 1. Place the rear log as shown, ensuring the holes on the underside are placed onto the 2 pins of the log support. In order to assemble the log set, the glass door must be removed, see Glass Door Installation and Removal .
27 W415-0612 / C / 01.25.08 Randomly place the charcoal embers along the front and sides of the burner in a realistic manner . Fine dust found in the bottom of the bag should not be used. Sprinkle vermiculite around the charcoal embers. Note: Both charcoal embers and vermiculite are not to be placed on the burner ports.
28 W415-0612 / C / 01.25.08 WIRING DIA GRAM The main burner and Night Light TM switch is located behind lower access panel. For ease of accessibility , optional re- mote wall switches may be installed in a convenient location for both burner and light operation.
29 W415-0612 / C / 01.25.08 1. STOP! READ THE ABOVE SAFETY INFORMA TION ON THIS LABEL. 2. TURN REMOTE W ALL SWITCH TO OFF POSITION. 3. TURN OFF ALL ELECTRIC POWER T O THE FIREPLACE AND REMOVE BA TTERIES. 4. THIS FIREPLACE IS EQUIPPED WITH AN IGNITION DEVICE WHICH AUT OMA TICALL Y LIGHTS THE PILOT .
30 W415-0612 / C / 01.25.08 FIGURE 65 1. Turn of f the electrical and gas supply to the fi replace. 2. Remove the front, glass viewing door and log set. 3. Remove the 2 securing screws. Slide the burner assembly to the right and lift out. 4. Using a deep 9 / 16 ” socket wrench, remove the main burner ori fi ce.
31 W415-0612 / C / 01.25.08 Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon® d ealer or distributor. When ordering replacement parts always give the following information: 1.
32 W415-0612 / C / 01.25.08 25 29 6 7 27 5 12 1 2 3 21 8 18 24 21 20 23 22 17 31 4 32.
33 W415-0612 / C / 01.25.08 Pilot will not light. V erify the "S" wire for the sensor and the "I" wire for the ignitor are connected to the correct terminals (not reverse) on the module and pilot assembly . V erify no loose connections, electrical shorts in the wiring or ground out to any metal object.
34 W415-0612 / C / 01.25.08 Flames are very ag- gressive. - V enting action is too great. Realign door and secure. Restrict vent exit with restrictor plate. See Restricting V ents. - Door is ajar Main burner fl ame is a blue, lazy , transparent fl ame.
35 W415-0612 / C / 01.25.08 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS.
36 W415-0612 / C / 01.25.08 NO TES.
Een belangrijk punt na aankoop van elk apparaat Napoleon Fireplaces GD19P (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Napoleon Fireplaces GD19P heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Napoleon Fireplaces GD19P vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Napoleon Fireplaces GD19P leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Napoleon Fireplaces GD19P krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Napoleon Fireplaces GD19P bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Napoleon Fireplaces GD19P kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Napoleon Fireplaces GD19P . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.