Gebruiksaanwijzing /service van het product GD80NT van de fabrikant Napoleon Fireplaces
Ga naar pagina of 28
1 W415-0447 / B / 05.24.05 W415-0447 / B / 05.24.05.
2 W415-0447 / B / 05.24.05 WHA T T O DO IF Y OU SMELL GAS WARNINGS & SAFETY PRECA UTIONS.
3 W415-0447 / B / 05.24.05 PG2-6 INTR ODUCTION W arnings and Safety Precautions W arranty Dimensions General Instructions General Information Care of Glass & Plated Parts 6- 11 VENTING V ent lengt.
4 W415-0447 / B / 05.24.05 ALL SPECIFICA TIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL L TD. PA TENTS U.S. 5.303.693.801 - CAN. 2.073.41 1, 2.082.915.
5 W415-0447 / B / 05.24.05 Pur ge all g as lines with the glass door of the fire place open. Assure tha t a continuous g as f low is at the b urner befor e cl o s i ng the door . Under e xtreme v ent configura tions , allow several min utes (5-15) for the flame to stabiliz e after ignition.
6 W415-0447 / B / 05.24.05 Do not use abrasive cleaners to clean plated parts. Buff lightly with a clean dry cloth. The glass is 3/16" ceramic glass available from your Napoleon / Wolf S teel Ltd. dealer . DO NOT SUBSTITUTE MA TERIALS. Clean the glass after the first 10 hours of operation with a recommended gas fireplace glass cleaner .
7 W415-0447 / B / 05.24.05 when (H T ) < (V T ) Simple venting configuration (only one 90° elbow) VERTICAL RISE IN FEET V T FIGURE 4 See graph to determine the required vertical rise V T for the required horizontal run H T .
8 W415-0447 / B / 05.24.05 H 2 H 1 V 1 90° See graph to determine the required verti- cal rise V T for the required horizontal run H T . V 1 = V T = 6 ft H 1 =3 f t H 2 =5 f t H R = H 1 + H 2 = 3 + 5 = 8 ft H O = .03(two 90° elbows - 90°) = .03(180° - 90°) = 2.
9 W415-0447 / B / 05.24.05 REQUIRED VERTICAL RISE IN FEET V T HORIZONT AL VENT RUN PLUS OFFSET IN FEET H T The shaded area within the lines represents acceptable values for H T and V T .
10 W415-0447 / B / 05.24.05 MAXIMUM VERTICAL RISE IN FEET V T HORIZONT AL VENT RUN PLUS OFFSET IN FEET H T The shaded area within the lines represents acceptable values for H T and V T . See graph to determine the required vertical rise V T for the required horizontal run H T .
11 W415-0447 / B / 05.24.05 AIR TERMINAL INST ALLA TIONS * * * * * Recommended to prevent condensation on windows and thermal breakage ** ** ** ** ** It is recommended to use a hea t shield and to maximiz e the distance to vinyl clad soffits. *** *** *** *** *** The periscope GD-201 requir es a minimum 18 inches c lear ance fr om an inside corner .
12 W415-0447 / B / 05.24.05 ROUND OR SQUARE HOLE 12.500" 16.000" c /c 14 7 / 16 " 13" FIGURE 13 This application occurs when venting through an exterior wall. Having determined the air terminal location, cut and frame a hole in an exterior wall.
13 W415-0447 / B / 05.24.05 FIGURE 19 4. Insert the liners through the firestop maintaining the required clearance to combustibles. Secure to the exterior wall and make weather tight by sealing with caulking (not supplied).
14 W415-0447 / B / 05.24.05 FIGURE 23 The vent system must be supported approximately every 3 feet for both vertical and horizontal runs. Use W olf Steel vent spacers or equivalent every 3 feet and either side of each elbow to maintain the minimum 1¼" clearance between the outer and inner vent pipes.
15 W415-0447 / B / 05.24.05 Pr oceed once the vent installa tion is complete . Note : All gas connections must be contained within the fireplace when complete . 1. The fireplace is de- signed to accept a ½" gas supply line. The fireplace is equipped with a ½" manual shut-off valve, and an 18" listed flexible gas connector .
16 W415-0447 / B / 05.24.05 WARNING Facing and/or finishing material must never o verhang into the fireplace opening. Do not distor t or f o rce the fr ame kit components. W hen using a r ough finish material (i.e.; stone), maintain a ¼” - ½” border from the framing components.
17 W415-0447 / B / 05.24.05 FIGURE 34 MANTLE CLEARANCES Combustible mantle clearance can vary according to the mantle depth. Use the graph to help evaluate the clearance needed.
18 W415-0447 / B / 05.24.05 Before the glass door can be removed, the control doors must be removed and the hearth strip and screen assembly must be removed. Lift the hearth strip up and away from the front of the fire- place. The curtain assembly can be removed by lifting the rod out from the three hooks at the top inside edge of the door opening.
19 W415-0447 / B / 05.24.05 Glowing embers are NOT recommended. The burner has been designed to achieve maximum glow without embers. 4. Place log #4, with the charred branch pointed inward. Locate the pins into the holes in log#1 and log#2, this will hold the rear log in position.
20 W415-0447 / B / 05.24.05 BLO WER REPLACEMENT The Napoleon MADISON comes equipped with a heat circu- lating blower . The blower is pre-wired and is controlled by the remote control supplied with the unit. For control details, see operation. Pg . 22.
21 W415-0447 / B / 05.24.05 FIGURE 48 1. Unplug the cord from the junction box 2. Pull the the tab on the receiver lock forward. 3. Pull up on the receiver and disconnect the wires. 4. Install the new receiver (see schematic Pg.23) . 1. Remove the hearth strip.
22 W415-0447 / B / 05.24.05 The timer setting is used to maintain the desired room temperature for a specific length of time (1 to 120 minutes) that you want the fireplace to operate. Press the TIMER button once. The LCD will blink "_ _ _". Adjust the time using the up or down arrow keys.
23 W415-0447 / B / 05.24.05 A . This fireplace is equipped with a pilot which must be lit by hand while following these instructions exactly . B. Before operating smell all around the fireplace area for gas and next to the floor because some gas is heavier than air and will settle on the floor .
24 W415-0447 / B / 05.24.05 Closing the air shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports. The flame may not appear yellow immediately; allow 15 to 30 minutes for the final flame colour to be established.
25 W415-0447 / B / 05.24.05 # P ART NO . DESCRIPTION 1 W135-0205 # 1 - REAR LOG 2 W135-0206 # 2 - MIDDLE LOG - NG 3 W135-0207 #3 - RIGHT LOG 4 W135-0208 #4 - LEFT LOG 5 W135-0218 #5 - CROSSOVER LOG 6 .
26 W415-0447 / B / 05.24.05 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf S teel Ltd.
27 W415-0447 / B / 05.24.05 White / grey film forms. Sulphur from fuel is being de- posited on glass, logs or com- bustion chamber surfaces. - clean the glass with a gas fireplace glass cleaner . DO NOT CLEAN GLASS WHEN HOT . If deposits are not cleaned of f regularly , the glass may become per- manently marked.
28 W415-0447 / B / 05.24.05 Remote wall switch is in "OFF" position; main burner comes on when gas knob is turned to "ON" posi- tion. W all switch is mounted up- side down - reverse. Faulty valve. - replace. - replace. Remote wall switch is grounding.
Een belangrijk punt na aankoop van elk apparaat Napoleon Fireplaces GD80NT (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Napoleon Fireplaces GD80NT heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Napoleon Fireplaces GD80NT vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Napoleon Fireplaces GD80NT leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Napoleon Fireplaces GD80NT krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Napoleon Fireplaces GD80NT bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Napoleon Fireplaces GD80NT kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Napoleon Fireplaces GD80NT . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.